The site is undergoing maintenance. Ordering can continue through fax and phone.
Sunday, August 16, 2026, 1:30 - 4:30 pm (SAST).
If you encounter problems while ordering. Please contact us at BDBCustomerService@bd.com
See MoreYour selected location is
Middle East / Africa
The site is undergoing maintenance. Ordering can continue through fax and phone.
Sunday, August 16, 2026, 1:30 - 4:30 pm (SAST).
If you encounter problems while ordering. Please contact us at BDBCustomerService@bd.com
See MoreThe site is undergoing maintenance. Ordering can continue through fax and phone.
Sunday, August 16, 2026, 1:30 - 4:30 pm (SAST)
.If you encounter problems while ordering. Please contact us at BDBCustomerService@bd.com
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location site or be switched to your location?
Flow cytometric analysis of Alexa 488 anti-human HLA-A,B,C on lymphocytes. Whole blood was stained with Alexa 488 anti-human HLA-A,B,C (clone DX17 , Cat. No. 560169) and compared to whole blood stained with a Alexa 488 mouse IgG1 isotype control (clone MOPC-21, Cat. No. 557702). The isotype control is represented by a dashed line and the Alexa 488 anti-human HLA-A,B,C by the solid line. Flow cytometry was performed on a BD FACSCalibur™ System and the histograms were derived from the gated events based on light scattering characteristics of viable cells.
Flow cytometric analysis of Alexa 488 anti-human HLA-A,B,C on lymphocytes. Whole blood was stained with Alexa 488 anti-human HLA-A,B,C (clone DX17 , Cat. No. 560169) and compared to whole blood stained with a Alexa 488 mouse IgG1 isotype control (clone MOPC-21, Cat. No. 557702). The isotype control is represented by a dashed line and the Alexa 488 anti-human HLA-A,B,C by the solid line. Flow cytometry was performed on a BD FACSCalibur™ System and the histograms were derived from the gated events based on light scattering characteristics of viable cells.
Flow cytometric analysis of Alexa 488 anti-human HLA-A,B,C on lymphocytes. Whole blood was stained with Alexa 488 anti-human HLA-A,B,C (clone DX17 , Cat. No. 560169) and compared to whole blood stained with a Alexa 488 mouse IgG1 isotype control (clone MOPC-21, Cat. No. 557702). The isotype control is represented by a dashed line and the Alexa 488 anti-human HLA-A,B,C by the solid line. Flow cytometry was performed on a BD FACSCalibur™ System and the histograms were derived from the gated events based on light scattering characteristics of viable cells.
Flow cytometric analysis of Alexa 488 anti-human HLA-A,B,C on lymphocytes. Whole blood was stained with Alexa 488 anti-human HLA-A,B,C (clone DX17 , Cat. No. 560169) and compared to whole blood stained with a Alexa 488 mouse IgG1 isotype control (clone MOPC-21, Cat. No. 557702). The isotype control is represented by a dashed line and the Alexa 488 anti-human HLA-A,B,C by the solid line. Flow cytometry was performed on a BD FACSCalibur™ System and the histograms were derived from the gated events based on light scattering characteristics of viable cells.
Flow cytometric analysis of Alexa 488 anti-human HLA-A,B,C on lymphocytes. Whole blood was stained with Alexa 488 anti-human HLA-A,B,C (clone DX17 , Cat. No. 560169) and compared to whole blood stained with a Alexa 488 mouse IgG1 isotype control (clone MOPC-21, Cat. No. 557702). The isotype control is represented by a dashed line and the Alexa 488 anti-human HLA-A,B,C by the solid line. Flow cytometry was performed on a BD FACSCalibur™ System and the histograms were derived from the gated events based on light scattering characteristics of viable cells.
Flow cytometric analysis of Alexa 488 anti-human HLA-A,B,C on lymphocytes. Whole blood was stained with Alexa 488 anti-human HLA-A,B,C (clone DX17 , Cat. No. 560169) and compared to whole blood stained with a Alexa 488 mouse IgG1 isotype control (clone MOPC-21, Cat. No. 557702). The isotype control is represented by a dashed line and the Alexa 488 anti-human HLA-A,B,C by the solid line. Flow cytometry was performed on a BD FACSCalibur™ System and the histograms were derived from the gated events based on light scattering characteristics of viable cells.
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
The DX17 monoclonal antibody reacts with a monomorphic epitope expressed on all HLA (human leukocyte antigen) class I molecules examined. DX17 immunoprecipitates HLA class I heavy chains (45 kDa) and β2-microglobulin (12kDa) from radiolabeled human cell lines. HLA is determined by a complex segment of the short arm of chromosome 6 and there are many human HLAs encoded in this segment. The antigenic agglomerate is called MHC, for major histocompatibility complex. Examples of class I loci are HLA-A, -B, and -C, which are serologically assayed; class II loci, e.g., HLA-D/DR and DC1, are tested by lymphocytotoxic methods.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.