Skip to main content Skip to navigation
PerCP Rat Anti-Mouse IgG1
Product Details
Down Arrow Up Arrow


BD™
Igh-4; Ighg1; Immunoglobulin heavy constant gamma 1
Mouse
Rat LOU, also known as Louvain, LOU/C, LOU/M IgG1, κ
Mouse IgG1, κ Antibody
Flow cytometry
20 μL
16017
Phosphate buffered saline with gelatin and 0.1% sodium azide.
RUO


Preparation And Storage

The PE and PerCP conjugates are supplied in 2.0 mL of PBS containing gelatin and 0.1% sodium azide. Please refer to the vial label for antibody concentration. The vial should be stored at 2° to 8°C. Conjugated forms should not be frozen and should be protected from prolonged exposure to light. Each reagent is stable for the period shown on the bottle label when stored as directed.

340272 Rev. 1
Antibody Details
Down Arrow Up Arrow
X56

Rat Anti-Mouse IgG1, clone X56, is derived from hybridization of rat YB2/0 myeloma cells with spleen cells from LOU/M rats immunized with CD4 antibody. (CD4 is composed of mouse IgG1 heavy chains and kappa light chains.)

340272 Rev. 1
Format Details
Down Arrow Up Arrow
PerCP
PerCP dye is part of the BD blue family of dyes. This dye is a fluorescent protein complex with an excitation maximum (Ex Max) of 481 nm and an emission maximum (Em Max) at 675 nm. PerCP is designed to be excited by the blue laser (488 nm) and detected using an optical filter centered near 680 nm (e.g., a 695/40 nm bandpass filter). The donor dye can be partially excited by the Violet (405 nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PerCP
Blue 488 nm
481 nm
675 nm
340272 Rev.1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.