Skip to main content Skip to navigation
PE Mouse Anti-Human CD89
Alert icon
Consider BD Horizon RealYellow™ 586 (RY586) Reagents, a bright and clean fluorochrome alternative to PE off the yellow-green laser. RY586 can be used alongside PE on spectral cytometers. More Info #
PE Mouse Anti-Human CD89
Flow cytometric analysis of CD89 expression on human peripheral blood granulocytes. Whole blood was stained with either PE Mouse Anti-Human CD89 (Cat. No. 555686; solid line histogram) or PE Mouse IgG1, κ Isotype Control (Cat. No. 555749; dashed line histogram). Erythrocytes were lysed with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899). Fluorescent histograms were derived from gated events with the forward and side light-scattering characteristics of viable granuloctyes. Flow cytometry was performed on a BD FACScan™ system.
Flow cytometric analysis of CD89 expression on human peripheral blood granulocytes. Whole blood was stained with either PE Mouse Anti-Human CD89 (Cat. No. 555686; solid line histogram) or PE Mouse IgG1, κ Isotype Control (Cat. No. 555749; dashed line histogram). Erythrocytes were lysed with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899). Fluorescent histograms were derived from gated events with the forward and side light-scattering characteristics of viable granuloctyes. Flow cytometry was performed on a BD FACScan™ system.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
FCAR; IgA Fc receptor; FcαR; FcalphaRI; CTB-61M7.2
Human (QC Testing)
Mouse BALB/c IgG1, κ
Purified Human FcαR
Flow cytometry (Routinely Tested)
20 µl
V MA104
2204
AB_396037
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
555686 Rev. 7
Antibody Details
Down Arrow Up Arrow
A59

The A59 monoclonal antibody specifically recognizes CD89. CD89 is the Fc receptor for IgA (FcαR), a 55-75 kDa glycoprotein expressed exclusively on cells of granulocytic and monocyte/macrophage lineages in peripheral blood, but not on lymphocytes. It is also expressed on promyelocytes in bone marrow and in the cytoplasm of fixed monocytes. This mAb does not block IgA binding and is more efficient than native IgA ligands in the isolation of FcαR molecules. FcαR plays a role in triggering phagocytosis and respiratory burst.

555686 Rev. 7
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
555686 Rev.7
Citations & References
Down Arrow Up Arrow

Development References (4)

  1. Monteiro RC, Cooper MD, Kubagawa H. Molecular heterogeneity of Fc alpha receptors detected by receptor-specific monoclonal antibodies. J Immunol. 1992; 148(6):1764-1770. (Biology). View Reference
  2. Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995.
  3. Shen L, Collins JE, Schoenborn MA, Maliszewski CR. Lipopolysaccharide and cytokine augmentation of human monocyte IgA receptor expression and function. J Immunol. 1994; 152(8):4080-4086. (Biology). View Reference
  4. Shen L. A monoclonal antibody specific for immunoglobulin A receptor triggers polymorphonuclear neutrophil superoxide release. J Leukoc Biol. 1992; 51(4):373-378. (Biology). View Reference
View All (4) View Less
555686 Rev. 7

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.