Skip to main content Skip to navigation
BD Horizon RealYellow™ 743 Reagents

A Bright, Clean Dye

BD Horizon RealYellow743 (RY743) Reagents leverage an innovative laser-specific fluorochrome, excited primarily by the 561-nm yellow-green laser to offer:
 

  • Limited cross-laser excitation from the 488-nm blue laser
  • A bright fluorochrome to support the detection of low-expression surface and intracellular markers
  • Reduced nonspecific monocyte binding compared to legacy PE tandem fluorochromes
  • Compatibility with spectral and appropriately configured* conventional flow cytometers


*Filter centered near 750 nm, e.g., 750/30

 
RY743 Vials
performance1

RY743 Reagents Can Be Used in Higher Parameter Flow Cytometry Panels to Increase Biological Resolution

RY743 Specifications

 

FormatEx MaxEm MaxSpectralConventionalRelative BrightnessSpillover* (1 = low, 4 = high)Alternative To
RY743557 nm743 nm 2PE/Fire 744, NovaFluor Yellow 755
 
*Value may vary based on instrument configuration and settings. Spillover ranking is based on cross-laser excitation on five-laser spectral instruments and does not take into account spillover into adjacent detectors.
 

View Products

Performance

BD Horizon RealYellow 743 Reagents Are Very Bright with Reduced Spillover and Monocyte Background


RY743 has greatly reduced cross-laser excitation

RY743 Excitation 488NM Blue Laser

Normalized emission profiles of CD4 (SK3) RY743, PE/Fire 744 and NovaFluor Yellow 755 (NFY755) Fluorochromes. Human CD4 (SK3) antibody acquired on a BD FACSDiscoverS8 Cell Sorter.

RY743 has reduced spread into RB744 compared to PE/Fire 744
RY743 reduced cross laser excitation

PBMCs were stained with CD4 RY743, NFY755, PE/Fire 744 or RB744. Cells were acquired and analyzed on a Cytek Aurora Spectral Analyzer and unmixed with FlowJo Software. Single-color stains are overlaid.

 

RY743 has minimal monocyte background compared to PE-Cy7
RY743 Minimal Monocyte Background


Human whole blood was stained with Mouse IgG1, K Isotype Control (X40), CD3 (UCHT1), CD8 (RPA-T8) or CD19 (SJ25C1) PE-Cy7 or RY743 followed by lysis with BD Pharm Lyse Lysing Solution. Samples run on a BD FACSymphony A5 SE Cell Analyzer.


View Products

Applications

Multicolor Flow Cytometry

BD Horizon RY743 Reagents Have Excellent Resolution as Demonstrated in an 18-color Spectral Flow Cytometry Panel Acquired on the BD FACSDiscoverS8 Cell Sorter


BD Horizon RealYellow and RealBlueReagents work well together in an 18-color spectral murine immunophenotyping panel
18 Color Spectral Flow Cytometry Panel on FBD ACSDiscover S8

BALB/c mouse spleen cells or lymph nodes and Peyer’s patches were stained with a viability dye and antibodies against cell surface markers. Brilliant Stain Buffer was used to mitigate dye-to-dye interactions. Cells were then fixed and permeabilized using the BD Pharmingen Transcription Factor Buffer Set and stained with antibodies against transcription factors. Cells were analyzed on a BD FACSDiscover™ S8 Cell Sorter and data were analyzed with FlowJo (v10) Software. A gating strategy for detection and phenotyping of various cell types, including T follicular helper cells (Tfh), T follicular regulatory cells (Tfr), Tregs and germinal center (GC) B-cells, after exclusion of dead cells and doublets, is shown.

Fluorochrome marker assignment for an 18-color spectral flow cytometry panel
 
 SpecificityCloneFluorochrome
UV
349 nm

CD3

145-2C11

BUV395

Violet
405 nm

FoxP3

MF23

BV421

CD62L

MEL-14

BV480

Live/dead

N/A

FVS575V

IgD

11-26c.2a

BV786

Blue
488 nm

iCOS

7E.17G9

BB515

CD4

GK1.5

RB545

CXCR5

2G8

RB613

GL-7

GL7

RB705

CD95

Jo2

RB744

BCL16

K112-91

RB780

Yellow-Green
561 nm

PD-1

RMP1-30

RY586

CD44

IM7

RY610

CD11b

M1/70

RY703

Helios

22F6

RY743

B220

RA3-6B2

RY775

Red
637 nm

CD8a

53-6.7

APC

CD25

7D4

R718


Fluorochrome marker assignment for an 18-color spectral flow cytometry panel acquired on the BD FACSDiscover S8 Cell Sorter.


View Products

Buffer Compatibility

BD Horizon RealYellow 743 Reagents Are Compatible with a Broad Range of Fixation and Permeabilization Systems

 

BuffersResults
BD FACS™ Lysing Solution and BD Pharm Lyse™ Lysing BufferCompatible
BD Cytofix™ Fixation BufferStable at least 24 hours
1% PFAStable at least 24 hours
BD Cytofix/Cytoperm™ Fixation and Permeabilization SolutionCompatible with antibody staining before and after fixation
BD FACS™ Permeabilizing Solution 2Compatible with antibody staining before and after fixation
BD Phosflow™ Perm Buffer IIICompatible with antibody staining before and after fixation
EDTA and HeparinCompatible
BD Horizon™ Brilliant Stain Buffer (BSB)Compatible
 

    

   

BD flow cytometers are Class 1 Laser Products. For Research Use Only. Not for use in diagnostic or therapeutic procedures.

CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva. CellBlox is a trademark of Thermo Fisher Scientific.