-
Your selected country is
Australia
- Change country/language
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).
Product Notices
- This antibody was developed for use in flow cytometry.
- The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
- Researchers should determine the optimal concentration of this reagent for their individual applications.
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
- BD Horizon Brilliant™ Violet 750 is covered by one or more of the following US patents: 8,158,444; 8,802,450; 8,575,303; 8,455,613; 8,227,187; 8,841,072; 8,110,673.
Companion Products
The MEM-238 monoclonal antibody specifically binds to CD222, which is also known as the Insulin-like growth factor 2 Receptor (IGF2R, IGF-II Receptor), Cation-independent mannose 6-phosphate receptor (CIMPR), or Mannose-6 phosphate receptor (M6PR). CD222 is ubiquitously expressed by a variety of cell types as a cell surface type I transmembrane glycoprotein. However, in the course of receptor trafficking between the cell surface and intracellular compartments, the majority of CD222 is found within cells. Cell surface CD222 functions as a multifunctional receptor that binds to a large number of extracellular ligands including acid hydrolases, insulin-like growth factors, latent TGF-β, leukemia inhibitory factor (LIF), proliferin, prorenin, plasminogen, and Herpes simplex virus. It regulates extracellular Insulin-like growth factor II (IGF-II/IGF-2) levels by binding and internalizing the growth factor for lysosomal degradation. This effectively removes IGF-II from the circulation and tissues and thus prevents it from signaling through the growth-stimulatory Insulin-like growth factor I Receptor (IGF-1R, CD221) pathway. However, studies have reported that IGF-II may activate some cellular functions through CD222 as well. A soluble form of the CD222 extracellular region can also be detected in human serum and may play a role in regulating IGF-II activity. CD222 serves as a surface receptor for latent TGFβ and can complex with plasminogen and CD87, a urokinase-type plasminogen activator receptor, to activate latent TGF-β. CD222 also binds to a variety of Mannose 6-phosphate (M6P)-containing proteins, including extracellular and newly-synthesized lysosomal enzymes, and transports them to lysosomes.
The antibody was conjugated to BD Horizon™ BV750 which is part of the BD Horizon Brilliant™ Violet family of dyes. This dye is a tandem fluorochrome of BD Horizon BV421 with an Ex Max of 405-nm and an acceptor dye with an Em Max at 750-nm. BD Horizon Brilliant BV750 can be excited by the violet laser (405 nm) and detected with a 750/30 nm filter with a 740 nm long pass. Due to spectral differences between labeled cells and beads, using BD™ CompBeads can result in incorrect spillover values when used with BD Horizon BV750 reagents. Therefore, the use of BD CompBeads or BD CompBeads Plus to determine spillover values for these reagents is not recommended.
Development References (4)
-
Brown J, Jones EY, Forbes BE. Keeping IGF-II under control: lessons from the IGF-II-IGF2R crystal structure. Trends Biochem Sci. 2009; 34(12):612-619. (Biology). View Reference
-
Godar S, Leska V, Cebecauer M, Hilgert I, Horejsi V, Stockinger H. Cd222 (Mannose-6 phosphate/insulin-like growth factor II-receptor) Summary and Workshop report. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:482-485.
-
Leksa V, Godar S, Cebecauer M, et al. The N terminus of mannose 6-phosphate/insulin-like growth factor 2 receptor in regulation of fibrinolysis and cell migration. J Biol Chem. 2002; 277(43):40575-40582. (Immunogen: Flow cytometry, Western blot). View Reference
-
Leksa V, Godar S, Schiller HB, et al. TGF-beta-induced apoptosis in endothelial cells mediated by M6P/IGFII-R and mini-plasminogen. J Cell Sci. 2005; 118(Pt19):4577-4586. (Clone-specific: Flow cytometry, Fluorescence microscopy, Immunoaffinity chromatography, Immunofluorescence, Immunoprecipitation, Western blot). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.
Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.