Skip to main content Skip to navigation
BV421 Rat Anti-Mouse CD93 (Early B Lineage)
BV421 Rat Anti-Mouse CD93 (Early B Lineage)
Two-color flow cytometric analysis of CD93 (Early B Lineage) expression on mouse bone marrow cells. Mouse bone marrow cells were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with APC Rat Anti-Mouse CD45R/B220 antibody (Cat. No. 553092/561880) and either BD Horizon™ BV421 Rat IgG2b, κ Isotype Control (Cat. No. 562603; Left Panel) or BD Horizon™ BV421 Rat Anti-Mouse CD93 (Early B Lineage) antibody (Cat. No. 563806; Right Panel). The two-color flow cytometric dot plots show the correlated expression patterns of CD93 (Early B Lineage) (or Ig Isotype control staining) versus CD45R/B220 for gated events with the forward and side-light scattering characteristics of viable bone marrow cells. Flow cytometric analysis was performed using a BD™ LSR II Flow Cytometer System.
Two-color flow cytometric analysis of CD93 (Early B Lineage) expression on mouse bone marrow cells. Mouse bone marrow cells were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with APC Rat Anti-Mouse CD45R/B220 antibody (Cat. No. 553092/561880) and either BD Horizon™ BV421 Rat IgG2b, κ Isotype Control (Cat. No. 562603; Left Panel) or BD Horizon™ BV421 Rat Anti-Mouse CD93 (Early B Lineage) antibody (Cat. No. 563806; Right Panel). The two-color flow cytometric dot plots show the correlated expression patterns of CD93 (Early B Lineage) (or Ig Isotype control staining) versus CD45R/B220 for gated events with the forward and side-light scattering characteristics of viable bone marrow cells. Flow cytometric analysis was performed using a BD™ LSR II Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD Horizon™
Aa4; Cd93; C1qRp; C1qr1; Ly-68; Ly68; C1q/MBL/SPA receptor
Mouse (QC Testing)
Rat SD, also known as Sprague-Dawley (outbred) IgG2b, κ
Pre-B lymphoma 70Z/3, derived from (C57BL/6 x DBA/2)F1 mouse
Flow cytometry (Routinely Tested)
0.2 mg/ml
AB_2869520
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV421 under optimum conditions, and unconjugated antibody and free BD Horizon BV421 were removed.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  5. Pacific Blue™ is a trademark of Molecular Probes, Inc., Eugene, OR.
  6. Brilliant Violet™ 421 is a trademark of Sirigen.
  7. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  8. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
563806 Rev. 1
Antibody Details
Down Arrow Up Arrow
AA4.1

The AA4.1 monoclonal antibody specifically recognizes the Early B Lineage antigen which is also known as CD93, AA4 antigen, Ly-68, and Complement component C1q receptor (C1qRp). This 130-140-kDa type I transmembrane glycoprotein is expressed on immature B lymphocytes in the adult bone marrow and on  hematopoietic progenitors and stem cells in adult bone marrow, fetal liver, and embryonic yolk sac. Although CD93+ cells are most plentiful in adult mouse bone marrow, a smaller number of CD93+ cells which express lower CD93 levels can be detected in the adult spleen using bright fluorescent conjugates of the AA4.1 antibody or an amplified indirect immunofluorescent staining procedure. It has been observed that the staining pattern of the 493 monoclonal antibody is similar to that of the AA4.1 antibody, in that both antibodies precipitate molecules of the same molecular weight. Staining with the AA4.1 antibody is not blocked by the 493 antibody. These results suggest that the antibodies recognize separate epitopes on the same Early B Lineage antigen.

The antibody was conjugated to BD Horizon™ BV421 which is part of the BD Horizon™ Brilliant Violet™ family of dyes.  With an Ex Max of 407-nm and Em Max at 421-nm, BD Horizon™ BV421  can be excited by the violet laser and detected in the standard Pacific Blue™ filter set (eg, 450/50-nm filter). BD Horizon™ BV421  conjugates are very bright, often exhibiting a 10 fold improvement in brightness compared to Pacific Blue™ conjugates.

563806 Rev. 1
Format Details
Down Arrow Up Arrow
BV421
The BD Horizon Brilliant Violet™ 421 (BV421) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This polymer-technology based dye has an excitation maximum (Ex Max) of 407-nm and an emission maximum (Em Max) at 423-nm. Driven by BD innovation, BV421 is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 420-nm (e.g., a 431/28-nm or 450/50-nm bandpass filter). BV421 is an ideal alternative for V450 as it is approximately ten times brighter with less spillover into the BV510/V500 detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV421
Violet 405 nm
407 nm
423 nm
563806 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "563806" on CiteAb

Development References (9)

  1. Allman D, Li J, Hardy RR. Commitment to the B lymphoid lineage occurs before DH-JH recombination. J Exp Med. 1999; 189(4):735-740. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
  2. Allman D, Lindsley RC, DeMuth W, Rudd K, Shinton SA, Hardy RR. Resolution of three nonproliferative immature splenic B cell subsets reveals multiple selection points during peripheral B cell maturation. J Immunol. 2001; 167(12):6834-6840. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
  3. Auerbach R, Huang H, Lu L. Hematopoietic stem cells in the mouse embryonic yolk sac. Stem Cells. 1996; 14(3):269-280. (Clone-specific). View Reference
  4. Jordan CT, McKearn JP, Lemischka IR. Cellular and developmental properties of fetal hematopoietic stem cells. Cell. 1990; 61(6):953-963. (Clone-specific: Flow cytometry). View Reference
  5. Lacaud G, Carlsson L, Keller G. Identification of a fetal hematopoietic precursor with B cell, T cell, and macrophage potential. Immunity. 1998; 9(6):827-838. (Clone-specific). View Reference
  6. Li YS, Wasserman R, Hayakawa K, Hardy RR. Identification of the earliest B lineage stage in mouse bone marrow. Immunity. 1996; 5(6):527-535. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
  7. McKearn JP, Baum C, Davie JM. Cell surface antigens expressed by subsets of pre-B cells and B cells. J Immunol. 1984; 132(1):332-339. (Immunogen: Cell separation, Depletion, Flow cytometry). View Reference
  8. Paige CJ, Gisler RH, McKearn JP, Iscove NN. Differentiation of murine B cell precursors in agar culture. Frequency, surface marker analysis and requirements for growth of clonable pre-B cells. Eur J Immunol. 1984; 14(11):979-987. (Clone-specific). View Reference
  9. Szilvassy SJ, Cory S. Phenotypic and functional characterization of competitive long-term repopulating hematopoietic stem cells enriched from 5-fluorouracil-treated murine marrow. Blood. 1993; 81(9):2310-2320. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
View All (9) View Less
563806 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.