Skip to main content Skip to navigation
PE Mouse IgG2a, κ Isotype Control
Product Details
Down Arrow Up Arrow


BD™
Mouse BALB/c IgG2a
KLH
Isotype control
25 µg/mL
Phosphate buffered saline with gelatin and 0.1% sodium azide.
RUO


Preparation And Storage

The γ2a control is provided as 25 μg of PE conjugate in 1 mL of buffer. The buffer is phosphate buffered saline (PBS) containing gelatin and 0.1% sodium azide. Vial should be stored at 2° to 8°C and protected from prolonged exposure to light. Conjugated forms should not be frozen. Each reagent is stable for the period shown on the bottle label when stored as directed.

340459 Rev. 1
Antibody Details
Down Arrow Up Arrow
X39

The Mouse IgG2a antibody, clone X39, is derived from the hybridization of mouse Sp2/0-Ag 14 myeloma cells with spleen cells from BALB/c mice immunized with KLH.

The Mouse IgG2a antibody reacts specifically with keyhole limpet hemocyanin (KLH), an antigen not expressed on human cells or human cell lines.

340459 Rev. 1
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
340459 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "340459" on CiteAb
No Citations Found

No Citations are available for this Product

340459 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.