Description

Becton Dickinson Immunocytometry Systems (BDIS) Simultest™ CD3/CD19 (Leu™-4/12) is a two-color direct immunofluorescence reagent for enumerating percentages of mature human T and B lymphocytes in erythrocyte-lysed whole blood (LWB).

Preparation And Storage

1. For in vitro diagnostic use.

2. When stored at 2° to 8°C, the antibody reagent is stable until the expiration date shown on the label. Do not use after the expiration date.

3. The antibody reagent should not be frozen or exposed to direct light during storage or during incubation with cells. Keep the reagent vial dry.

4. Alteration in the appearance of the reagent, such as precipitation or discoloration, indicates instability or deterioration. In such cases, the reagent should not be used.

5. The antibody reagent contains sodium azide as a preservative; however, care should be taken to avoid microbial contamination, which may cause erroneous results.

349211 Rev. 1
Components
Down Arrow Up Arrow
Description Clone Isotype EntrezGene ID
CD3 FITC SK7 IgG1, κ N/A
CD19 PE 4G7 IgG1, κ 916
349211 Rev. 1
Citations & References
Down Arrow Up Arrow

Development References (20)

  1. A National Committee for Clinical Laboratory Standards. Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture (H3-A3). 1991. (Biology).
  2. Antel J, Bania M, Noronha A, Neely S. Defective suppressor cell function mediated by T8+ cell lines from patients with progressive multiple sclerosis. J Immunol. 1986; 137:3436-3439. (Biology).
  3. Brenner M, Groh V, Porcelli A, et al. Knapp W, Dörken B, Gilks W, et al, ed. Leucocyte Typing IV: White Cell Differentiation Antigens. 1989:1049-1053.
  4. Clevers H, Alarcón B, Wileman T, Terhorst C. The T cell receptor/CD3 complex: a dynamic protein ensemble. Annual Rev Immunol. 1988; 6:629. (Biology).
  5. Dörken B, Möller P, Pezzutto A, Schwartz-Albiez R, Moldenhauer G. Knapp W, Dörken B, Gilks WR, et al, ed. Leucocyte Typing IV: White Cell Differentiation Antigens. New York, NY: Oxford University Press; 1989:34-36.
  6. Foucar K, Goeken JA. Clinical application of immunologic techniques to the diagnosis of lymphoproliferative and immunodeficiency disorders. Lab Med. 1982; 13:403-413. (Biology).
  7. Giorgi JV. Lymphocyte subset measurements: significance in clinical medicine. In: Rose NR, Friedman H, Fahey JL, ed. Manual of Clinical Laboratory Immunology. 3rd ed.. Washington, DC: American Society for Microbiology; 1986:236-246.
  8. Haynes BF. Summary of T-cell studies performed during the Second International Workshop and Conference on Human Leukocyte Differentiation Antigens. In: Reinherz EL. Ellis L. Reinherz .. et al., ed. Leukocyte typing II. New York: Springer-Verlag; 1986:3-30.
  9. Jackson AL, Warner NL. Rose NR, Friedman H, Fahey JL, ed. Manual of Clincial Laboratory Immunology, Third Edition. Washington DC: American Society for Microbiology; 1986:226-235.
  10. Kan EA, Wang CY, Wang LC, Evans RL. Noncovalently bonded subunits of 22 and 28 kd are rapidly internalized by T cells reacted with anti-Leu-4 antibody. J Immunol. 1983; 131(2):536-539. (Biology). View Reference
  11. Knowles R. Reinherz E, Haynes B, Nadler L, Bernstein I, ed. Leukocyte Typing II: Human T Lymphocytes. 1986:259-288.
  12. Ledbetter JA, Evans RL, Lipinski M, Cunningham-Rundles C, Good RA, Herzenberg LA. Evolutionary conservation of surface molecules that distinguish T lymphocyte helper/inducer and cytotoxic/suppressor subpopulations in mouse and man. J Exp Med. 1981; 153(2):310-323. (Biology). View Reference
  13. Nadler LM. B Cell/Leukemia Panel Workshop: summary and comments. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, ed. Leukocyte Typing II: Human B Lymphocytes. New York: Springer-Verlag; 1986:3-43.
  14. National Committee for Clinical Laboratory Standards. Clinical Applications of Flow Cytometry: Quality Assurance and Immunophenotyping of Peripheral Blood Lymphocytes; Tentative Guideline. 1992; 1992. (Biology).
  15. Ohno T, Kanoh T, Suzuki T, et al. Comparative analysis of lymphocyte phenotypes between carriers of human immunodeficiency virus (HIV) and adult patients with primary immunodeficiency using two-color immunofluorescence flow cytometry.. Tohoku J Exp Med. 1988; 154(2):157-72. (Biology). View Reference
  16. Prince H, Hirji K, Waldbeser L, Plaeger-Marshall S, Kleinman S, Lanier L. Influence of racial background on the distribution of T cell subsets and Leu-11-positive lymphocytes in healthy blood donors. Diag Immunol. 1985; 3:33-37. (Biology).
  17. Reichert T, DeBruyere M, Deneys V, et al. Lymphocyte subset reference ranges in adult Caucasians. Clin Immunol Immunopathol. 1991; 60(2):190-208. (Biology). View Reference
  18. Schmidt RE. Monoclonal antibodies for diagnosis of immunodeficiencies. Blut. 1989; 59:200-206. (Biology).
  19. Smolen J, Chused T, Leiserson W, Reeves J, Alling D, Steinberg A. Heterogeneity of immunoregulatory T-cell subsets in systemic lupus erythematosus. Am J Med. 1982; 72:783-790. (Biology).
  20. van Dongen JJM, Krissansen GW, Wolvers-Tettero ILM, et al. Cytoplasmic expression of the CD3 antigen as a diagnostic marker for immature T-cell malignancies. Blood. 1988; 71:603-612. (Biology).
View All (20) View Less
349211 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For In Vitro Diagnostics Use.

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.