Skip to main content Skip to navigation
BV786 Rat Anti-Mouse DCIR4 (Clec4a1)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
Clec4a1; DCIR4; Dcir4; dendritic cell inhibitory receptor 4
Mouse (Tested in Development)
Rat LEW, also known as Lewis IgG1, κ
Mouse DCIR4
Flow cytometry (Qualified)
0.2 mg/ml
AB_2875732
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Product Notices

  1. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  7. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. BD Horizon Brilliant Violet 786 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,455,613; 8,575,303; 8,354,239.
  10. Cy is a trademark of GE Healthcare.
751755 Rev. 1
Antibody Details
Down Arrow Up Arrow
MH7E7

The MH7E7 monoclonal antibody specifically recognizes the extracellular domain of mouse Dendritic cell inhibitory receptor 4 (DCIR4). DCIR4 is a lectin receptor that is encoded by Clec4a1 (C-type lectin domain family 4, member a1) which belongs to the dendritic cell immunoreceptor (DCIR) family. DCIR4 (Clec4a1) is variably expressed on CD11b+ monocytes found in peripheral blood, secondary lymphoid tissues and the bone marrow. DCIR4 (Clec4a1) is reportedly expressed at low levels on Ly-6C-positive inflammatory monocytes and at high levels on Ly-6C-negative patrolling monocytes. It is not significantly expressed on eosinophils and neutrophils.

The antibody was conjugated to BD Horizon™ BV786 which is part of the BD Horizon Brilliant™ Violet family of dyes. This dye is a tandem fluorochrome of BD Horizon BV421 with an Ex Max of 405-nm and an acceptor dye with an Em Max at 786-nm.  BD Horizon BV786 can be excited by the violet laser and detected in a filter used to detect Cy™7-like dyes (eg, 780/60-nm filter).

751755 Rev. 1
Format Details
Down Arrow Up Arrow
BV786
The BD Horizon Brilliant Violet™ 786 (BV786) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an Ex Max of 407-nm and an acceptor dye with an Em Max at 786-nm.  BV786, driven by BD innovation, is designed to be excited by the violet laser and detected using a filter, centered near 785 nm (e.g. 780/60 nm bandpass filter).  Please ensure that your instrument’s configurations (lasers and filters) are appropriate for this dye.
altImg
BV786
Violet 405 nm
407 nm
786 nm
751755 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "751755" on CiteAb

Development References (3)

  1. Flornes LM, Bryceson YT, Spurkland A, Lorentzen JC, Dissen E, Fossum S. Identification of lectin-like receptors expressed by antigen presenting cells and neutrophils and their mapping to a novel gene complex.. Immunogenetics. 2004; 56(7):506-17. (Biology). View Reference
  2. Hsu Y, Okada R, Nishimura T, Kawasaki N, Yamamoto K, Matsumoto N. DCIR3 and DCIR4 are co-expressed on inflammatory and patrolling monocytes. Biochem Biophys Res Commun.. 2017; 494(3-4):440-445. (Clone-specific: Flow cytometry). View Reference
  3. Kameda Y, Hanayama M, Kishimoto A, Kume M, Yamamoto K, Matsumoto N. Dendritic cell inhibitory receptor 4 (DCIR4) is preferentially expressed on inflammatory and patrolling monocytes.. Biochem Biophys Res Commun. 2016; 480(2):215-221. (Immunogen: Flow cytometry). View Reference
751755 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.