Preparation And Storage
Recommended Assay Procedures
For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).
Product Notices
- This antibody was developed for use in flow cytometry.
- The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
- Researchers should determine the optimal concentration of this reagent for their individual applications.
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
- BD Horizon Brilliant Violet 510 is covered by one or more of the following US patents: 8,575,303; 8,354,239.
Companion Products
The UP-H1 monoclonal antibody recognizes Immune receptor expressed by myeloid cells 2 (IREM-2) which is also known as CD300 antigen like family member E (CD300e), CMRF35-like molecule 2 (CLM2), or Polymeric immunoglobulin receptor 2 (PIgR2). IREM-2 is a 34 kDa type I transmembrane glycoprotein which belongs to the CMFRF35 subfamily of the immunoglobulin (Ig) superfamily. IREM-2 is expressed on monocytes, macrophages and myeloid dendritic cells (mDCs), but not on lymphoid dendritic cells or granulocytes. IREM-2 associates with DAP-12, an ITAM-containing adapter molecule, which provides activating signals. Crosslinking of IREM-2 leads to intracellular calcium mobilization, release of proinflammatory cytokines such as TNF, and increased expression of activation markers on monocytes and mDCs. IREM-2 activation of mDCs can reportedly enhance the alloreactive response of naive T cells.
The antibody was conjugated to BD Horizon™ BV510 which is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 405-nm and Em Max at 510-nm, BD Horizon BV510 can be excited by the violet laser and detected in the BD Horizon V500 (525/50-nm) filter set. BD Horizon BV510 conjugates are useful for the detection of dim markers off the violet laser.
Development References (3)
-
Aguilar H, Alvarez-Errico D, García-Montero AC, Orfao A, Sayós J, López-Botet M. Molecular characterization of a novel immune receptor restricted to the monocytic lineage. J Immunol. 2004; 173(11):6703-6711. (Immunogen: Flow cytometry, Immunoprecipitation, Radioimmunoassay). View Reference
-
Borrego F. The CD300 molecules: an emerging family of regulators of the immune system. Blood. 2013; 121(11):1951-1960. (Biology). View Reference
-
Brckalo T, Calzetti F, Pérez-Cabezas B, Borràs FE, Cassatella MA, López-Botet M. Functional analysis of the CD300e receptor in human monocytes and myeloid dendritic cells.. Eur J Immunol. 2010; 40(3):722-32. (Clone-specific: Flow cytometry). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.