
-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- BD® OMICS-One Protein Panels
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
-
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- BD® OMICS-One Protein Panels
- Germany (English)
-
Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Sphero™ Rainbow Calibration Particles (6 peaks), 3.0 - 3.4 µm



Rainbow Calibration Particles histogram (top row). Peak separation based on FL1 fluorescence intensity expressed in relative channel numbers. Rainbow Particle Calibration Graphs (bottom row). A graphical representation for the relative number of fluorophores per particle for each peak in FL1 (FITC, MEFL), FL2 (RPE, MEPE), FL3 (RPE-Cy5, MEPCY) and FL4 (APC, MEAP). Investigators should note that these calibration graphs are representative and specific lots may vary in performance.

Sphero™ Rainbow Calibration Particles (6 peaks), 3.0 - 3.4 µm
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Description
This product contains a mixture of 3.0 - 3.4 µm Rainbow Calibration Particles that are dyed to six different fluorescent intensities. Rainbow Calibration Particles (approx. 1 x 10^7 particles/mL) are designed for routine calibration of flow cytometers and contain a mixture of fluorophores that are excited at any wavelength from 365 - 650 nm. Rainbow Calibration Particles have emission spectra compatible with many common fluorophores used for immunofluorescent staining with flow cytometric analysis. Before use, mix or resuspend the particles by vortexing. Dilution of 3 - 5 drops of particles to 1 mL of sheath fluid will provide an adequate number of particles for flow cytometric analysis.
Preparation And Storage
Product Notices
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Cy is a trademark of GE Healthcare.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.