Skip to main content Skip to navigation
Cell Viability Solution

BD Via-Probe™ Cell Viability Solution

(RUO)
Product Details
Down Arrow Up Arrow


Description

BD Via-Probe™ is a convenient, ready-to-use solution of the nucleic acid dye, 7-Amino-actinomycin D (7-AAD) that can be used in place of propidium iodide (PI) for the exclusion of nonviable cells in flow cytometric assays. The advantage of 7-AAD over PI is the ability to be used in conjunction with phycoerythrin (PE)- and fluorescein (FITC)-labeled monoclonal antibodies in 2-color analysis, with minimal spectral overlap between the 7-AAD, PE and FITC fluorescence emissions. BD Via-Probe™ fluorescence is detected in the far red range of the spectrum (650 nm long-pass filter).  This reagent is used as a viability probe for methods of dead cell exclusion, based on light scatter and uptake of 7-AAD as detected in FL3. This reagent does not require dilution, use 20 µL/test (1x10^6 cells) and incubate for 10 minutes before analysis.



Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
Citations & References
Down Arrow Up Arrow

Development References (2)

  1. O'Brien MC, Bolton WE. Comparison of cell viability probes compatible with fixation and permeabilization for combined surface and intracellular staining in flow cytometry. Cytometry. 1995; 19(3):243-255. (Biology). View Reference
  2. Schmid I, Krall WJ, Uittenbogaart CH, Braun J, Giorgi JV. Dead cell discrimination with 7-amino-actinomycin D in combination with dual color immunofluorescence in single laser flow cytometry. Cytometry. 1992; 13(2):204-208. (Biology). View Reference

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.