Skip to main content Skip to navigation

BD Pharmingen™ Purified Mouse Anti-MLH-1 with Control

1327GF_551092_image1.png

Western blot analysis of MLH-1. Lysate from Jurkat cells were probed with Anti-MLH-1 (clone G168-15, Comp. No. 51-1327GR) at concentrations of 2.0 (lane 1), 1.0 (lane 2), and 0.5 µg/ml (lane 3). MLH-1 is identified as a band between 80-85 kDa.

1327GF_551092_image2.png

Immunohistochemical staining: Acetone-fixed, frozen tissue section of human colon carcinoma stained for MLH-1 (clone G168-15, Cat. No-) using a DAB chromogen and Hematoxylin counterstain. Cells expressing MLH-1 can be identifed by the intense brown labeling of their cell nuclei.

Western blot analysis of MLH-1. Lysate from Jurkat cells were probed with Anti-MLH-1 (clone G168-15, Comp. No. 51-1327GR) at concentrations of 2.0 (lane 1), 1.0 (lane 2), and 0.5 µg/ml (lane 3). MLH-1 is identified as a band between 80-85 kDa.

Immunohistochemical staining: Acetone-fixed, frozen tissue section of human colon carcinoma stained for MLH-1 (clone G168-15, Cat. No-) using a DAB chromogen and Hematoxylin counterstain. Cells expressing MLH-1 can be identifed by the intense brown labeling of their cell nuclei.

Product Details
Down Arrow Up Arrow


BD Pharmingen™
Human (QC Testing)
Western blot (Routinely Tested), Immunohistochemistry-frozen, Immunohistochemistry-paraffin (Tested During Development)
RUO
AB_394041


Preparation And Storage

Store undiluted at -20°C. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography.

Recommended Assay Procedures

Applications include western blot analysis (0.5-2.0 µg/ml) and immunohistochemical staining of frozen and paraffin-embedded tissue sections (5-20 µg/ml). Jurkat control lysate [50 µg (1 µg/µl)] is provided as a western blot control (Comp. No. 51-16526N; store lysate at -20°C). Additional Jurkat control lysate (Cat. No. 611451) is sold separately. Intestine or normal colon is suggested as a positive control for immunohistochemical staining. In intestine, staining is primarily nuclear and is seen in the crypts of Lieberkuhn, similar to that described in the literature. Both nuclear and cytoplasmic staining have been observed in a variety of other normal and tumor tissue and cell types. This clone is also available as Cat. No. 550838 in our special formulation for IHC application. Clone G168-728 (Cat. No. 554073) is recommended for immunoprecipitation of MLH1.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  5. Sodium azide is a reversible inhibitor of oxidative metabolism; therefore, antibody preparations containing this preservative agent must not be used in cell cultures nor injected into animals. Sodium azide may be removed by washing stained cells or plate-bound antibody or dialyzing soluble antibody in sodium azide-free buffer. Since endotoxin may also affect the results of functional studies, we recommend the NA/LE (No Azide/Low Endotoxin) antibody format, if available, for in vitro and in vivo use.
  6. For U.S. patents that may apply, see bd.com/patents.
551091 Rev. 2
Components
Down Arrow Up Arrow
Description Quantity/Size Part Number Clone Isotype
Purified Mouse Anti-Human MLH-1 50 µg (3 ea) 51-1327GR G168-15 IgG1,
Jurkat Cell Lysate 50 µg (1 ea) 51-16526N N/A N/A
551091 Rev. 2

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.