Biotin Mouse Anti-Rat MCP-1
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Rat (QC Testing)
Mouse IgG1
Recombinant Rat MCP-1 Protein
ELISA Detection (Routinely Tested), Immunoprecipitation (Reported)
0.5 mg/ml
AB_395685
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with biotin under optimum conditions, and unreacted biotin was removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

ELISA Detection: The biotinylated B4 antibody (Cat. No. 555074) can be used as the detection antibody in a sandwich ELISA for measuring rat MCP-1 protein levels in conjunction with purified C4 antibody (Cat. No. 555072) as the capture antibody and recombinant rat MCP-1 protein (Cat. No. 555110) as the standard.  This biotinylated detection antibody should be titrated in the range of 0.5 to 2 µg/ml to determine its optimal concentration for ELISA. To obtain linear standard curves, doubling dilutions of rat MCP-1 protein ranging from ~2,000 to 5 pg/ml are recommended for inclusion in each ELISA plate. For specific methodology, please visit the protocols section or chapter on ELISA in the Immune Function Handbook, both of which are posted on our web site, www.bdbiosciences.com. This ELISA pair shows no cross-reactivity with rat MIP-1α, MIP-1β, RANTES, MIP-2 or KC.

Note: This ELISA pair is recommended primarily for measuring cytokine from experimental cell culture systems. These ELISA reagents are not

recommended for assaying serum or plasma samples. For measuring MCP-1 in serum or plasma the rat MCP-1 BD OptEIA™ ELISA Set, Cat.

No. 555130, is specially formulated and recommended.

IP: The B4 antibody has been reported to be useful for immunoprecipitation studies. Please note that this application is not routinely tested at BD Biosciences Pharmingen.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
555074 Rev. 1
Antibody Details
Down Arrow Up Arrow
B4

The B4 antibody reacts with rat Monocyte Chemoattractant Protein 1 (MCP-1).  The immunogen used to generate this hybridoma was recombinant rat MCP-1 protein.

555074 Rev. 1
Format Details
Down Arrow Up Arrow
Biotin
Biotin is a ubiquitous co-factor (also known as Vitamin B7) that has many properties that make it extremely useful for molecular biology. Biotin has an extremely high affinity for the Avidin family of proteins (Kd = 10-15 M), making it the perfect tool to link two molecules. Biotin labeled antibodies can be combined with any number of Avidin-conjugated probes in order to customize an assay to a particular need. This is especially useful in the case of magnetic cell separation using streptavidin/magnetic bead conjugates, or in the case of flow cytometry using streptavidin/fluorophore conjugates.
Biotin
555074 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "555074" on CiteAb

Development References (1)

  1. Sakanashi Y, Takeya M, Yoshimura T, Feng L, Morioka T, Takahashi K. Kinetics of macrophage subpopulations and expression of monocyte chemoattractant protein-1 (MCP-1) in bleomycin-induced lung injury of rats studied by a novel monoclonal antibody against rat MCP-1. J Leukoc Biol. 1994; 56(6):741-750. (Clone-specific: ELISA, Immunoprecipitation). View Reference
555074 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.