Skip to main content Skip to navigation
PE Mouse Anti-Human CD15
PE Mouse Anti-Human CD15
Multiparameter flow cytometric analysis of CD15 expression on human peripheral blood leucocyte populations. Human whole blood was stained with either PE Mouse IgG1, κ Isotype Control (Cat No. 554680, Left Plot) or PE Mouse Anti-Human CD15 antibody (Cat No. 567102/567103, Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). A bivariate pseudocolor density plot showing the correlated expression of CD15 (or Ig Isotype control staining) versus side light-scatter signals (SSC) was derived from gated events with the forward and side light-scatter characteristics of intact human leucocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.
Multiparameter flow cytometric analysis of CD15 expression on human peripheral blood leucocyte populations. Human whole blood was stained with either PE Mouse IgG1, κ Isotype Control (Cat No. 554680, Left Plot) or PE Mouse Anti-Human CD15 antibody (Cat No. 567102/567103, Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). A bivariate pseudocolor density plot showing the correlated expression of CD15 (or Ig Isotype control staining) versus side light-scatter signals (SSC) was derived from gated events with the forward and side light-scatter characteristics of intact human leucocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
LeX; Lewis X; SSEA-1
Human (QC Testing)
Mouse BALB/c IgG1, κ
Human Polymorphonuclear Leucocytes
Flow cytometry (Routinely Tested)
5 µl
V MA088
2526
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cell and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
567103 Rev. 1
Antibody Details
Down Arrow Up Arrow
7C3.rMAb

The 7C3.rMAb is a recombinant monoclonal antibody that specifically recognizes human CD15 which is a terminal carbohydrate epitope, 3-fucosyl-N-acetyllactosamine (3-FAL), on cell surface glycoproteins or glycolipids. CD15 is also known as Lewis X (LeX), X-Hapten, or Stage-Specific Embryonic Antigen-1 (SSEA-1). The 7C3.rMAb was derived from the 7C3 (also known as, PMN7C3) hybridoma. The 7C3 antibody was validated at HLDA V (Workshop Number MA88). The 7C3.rMAb has the same IgV-region heavy chain domain and Ig, κ light chain as the original mouse 7C3 IgG3, κ antibody. The remaining Ig constant heavy chain of 7C3.rMAb is derived from the mouse IgG1 heavy chain. CD15 is expressed on a variety of cell types including neutrophils, eosinophils, monocytes, macrophages, mast cells, and Langerhans cells. CD15 is also expressed on some epithelial cells, activated lymphocytes as well as tumor cells. CD15 is not expressed by platelets or erythrocytes. CD15 plays various roles in mediating cellular adhesion, activation, migration, and phagocytosis.

        

567103 Rev. 1
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
567103 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "567103" on CiteAb

Development References (7)

  1. Ball ED, Persichetti J, Roscoe R, Nimgaonkar M, Winkelstein A. Expression of CD15 on CD34+ cells of the bone marrow, peripheral blood, and umbilical cord blood. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:795-798.
  2. Ball ED. CD15 cluster workshop report. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:790-794.
  3. Larsen GR, Sako D, Ahern TJ, et al. P-selectin and E-selectin. Distinct but overlapping leukocyte ligand specificities.. J Biol Chem. 1992; 267(16):11104-10. (Clone-specific: Cell separation). View Reference
  4. Masat T, Feliu E, Villamor N, et al. Immunophenotypic and ultrastructural study in peripheral blood neutrophil granulocytes following bone marrow transplantation.. Br J Haematol. 1997; 98(2):299-307. (Clone-specific: Flow cytometry). View Reference
  5. Nauseef WM, Root RK, Newman SL, Malech HL. Inhibition of zymosan activation of human neutrophil oxidative metabolism by a mouse monoclonal antibody.. Blood. 1983; 62(3):635-44. (Immunogen: Functional assay, Inhibition). View Reference
  6. Phillips ML, Schwartz BR, Etzioni A, et al. Neutrophil adhesion in leukocyte adhesion deficiency syndrome type 2.. J Clin Invest. 1995; 96(6):2898-906. (Clone-specific: Flow cytometry). View Reference
  7. Sedlak J, Chorvath B, Hunakova L, Bizik J, Karpatova M, Duraj J. CD15 (Lewisx) antigen: expression on non-hemopoietic cell lines and modulation on retinois-acid-induced HL-60 cells (analysedwith CD15 Panel mAb). In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:798-800.
View All (7) View Less
567103 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.