Skip to main content Skip to navigation

BD Horizon™Brilliant Stain Buffer

Prevent Dye-Dye Interactions in Multicolor Panels

BD Horizon™ Brilliant Stain Buffer (BSB) is required whenever a panel combines two or more BD Horizon™ Brilliant Polymer Dye-conjugated antibodies to prevent non-specific interactions. When multiple BD Horizon Brilliant™ Dyes are present in the same tube, their structures interact non-specifically. This can produce artifacts that mimic positive staining and are not removed by compensation. BSB mitigates these interactions. Without it, data from multicolor panels with several Brilliant Dyes can become uncertain. BSB is also helpful at reducing non-specific signals from anti-PEG antibodies when using BD Horizon Brilliant™ Dyes and BD Horizon™ Real Dyes in human whole blood.

Which Buffer Version Do You Need?

BD Horizon™ Brilliant Stain Buffer Plus is the concentrated version of BD Horizon™ Brilliant Stain Buffer to manage antibody staining volumes. Choose the one that fits your protocol.

 

 BD Horizon™ Brilliant Stain BufferBD Horizon™ Brilliant Stain Buffer Plus
Volume per test50 μL per tube or well10 μL per tube or well
Best forStandard staining protocols in tubes or 96-well platesApplications where total staining volume is constrained — intracellular staining with permeabilization buffers, low-volume plate formats
Compensation Bead CompatibilityBD™ CompBeads, BD™ SpectraComp™, BD™ SpectraComp™ XTBD™ CompBeads, BD™ SpectraComp™, BD™ SpectraComp™ XT
Storage4°C, protected from light, do not freeze4°C, protected from light, do not freeze


Use standard BSB at 50 μL per test when volume is not constrained. Use BSB Plus at 10 μL per test when limiting antibody cocktail volume is preferred, such as large panels where panel volumes may exceed 100 μL.

When is BSB Recommended?

Use BD Horizon™ Brilliant Stain Buffer whenever two or more BD Horizon Brilliant™ Dyes are in a single tube, or when anti-PEG antibodies might be present in your sample.

 

 

Recommended use

  • If two or more BD Horizon Brilliant™ Dyes—any combination of BD Horizon Brilliant™ Violet (BV), BD Horizon Brilliant™ Ultraviolet (BUV) and BD Horizon Brilliant™ Blue (BB) Dyes—are present in the same staining tube or well.
  • If one or more BD Horizon Brilliant™ Dye and BD Horizon™ Real Dye are used in a human whole blood protocol, to block anti-PEG antibodies in serum.
  • When staining consecutively, such as prestaining or intracellular staining, use BSB in each step where two or more BD Horizon Brilliant™ Dyes are included.
  • When single BD Horizon Brilliant™ Dyes are added at different staining steps (for example, one at surface staining and one at intracellular staining). BSB should be present when the two reagents are in contact with each other.

 


Not needed

  • For panels containing one or no BD Horizon Brilliant™ Dyes, except when staining human whole blood.  

 

Add BD Horizon™ Brilliant Stain Buffer to every staining tube in the experiment, including single-color compensation controls for non-Brilliant Dyes and match the exposure time of controls to the multicolor panel tubes. Evaluate compensation controls prepared without BSB to ensure accurate compensation and spectral unmixing.

 

 

Why Use BD Horizon™ Brilliant Stain Buffer?

 

BD Horizon Brilliant™ Dyes are polymer-based fluorochromes. They interact non-specifically when included in the same solution. This interaction produces artifacts that may appear as positive staining or undercompensated populations. BD Horizon™ Brilliant Stain Buffer mitigates these dye-dye interactions due to its specially designed proprietary composition. The buffer also contains polyethylene glycol (PEG) which can reduce background and aggregation in human whole blood assays by blocking anti-PEG antibodies. These anti-PEG antibodies found in human serum are more frequent in those vaccinated against SARS-CoV-2.

 


Available formats of BSB
 

ProductFormatStatusSize
BD Horizon™ Brilliant Stain Buffer

Liquid

RUO100 Tests, 1,000 Tests
BD Horizon™ Brilliant Stain Buffer Plus

Liquid

RUO100 Tests, 1,000 Tests

Protocol Overview

Before adding any BD Horizon Brilliant™ Reagents, add BSB first to every staining tube or well in the experiment. Compensation controls should be exposed to BSB as long as experimental samples to help ensure accurate compensation.

 

 

Preparation of individual panel (single-panel tubes)

  1. Add 50 μL of BD Horizon™ Brilliant Stain Buffer (or 10 μL of BD Horizon™ Brilliant Stain Buffer Plus) to each staining tube or well, including all single-color controls.
  2. Add each fluorescent antibody at the recommended volume per test.
  3. Ensure the final volume is at least 50 μL per test. If the combined volume of the stain buffer and antibodies is less than 50 μL, add BD Pharmingen™ Stain Buffer (FBS) to reach a final volume of 50 μL.
  4. Proceed with your standard staining protocol, including incubation, washing and acquisition.

 

 

Preparation of multiple panels (pre-mixed antibody cocktails) 

  1. Add 50 μL of BD Horizon™ Brilliant Stain Buffer (or 10 μL of BD Horizon™ Brilliant Stain Buffer Plus) per test to the cocktail tube or vial.
  2. Add each fluorescent reagent at the recommended volume per test, multiplied by the total number of tests, to the cocktail tube or vial.
    • Note that for cocktails containing more than one BD Horizon Brilliant™ UV Reagent, use the cocktail within 2 hours of preparation, regardless of storage temperature. Cocktails containing more than one BD Horizon Brilliant™ Violet or Brilliant Blue Reagent are best used within 4 hours when stored at room temperature or 24 hours when stored at 4°C, protected from light.
  3. Calculate the total antibody cocktail volume per test. If the volume is less than 50 μL per test, add BD Pharmingen™ Stain Buffer (FBS) to bring the final cocktail volume to 50 μL per test. 
  4. Dispense the calculated volume of the antibody cocktail into each staining tube or well and proceed with your standard staining protocol.

FAQs

  1. What is BD Horizon™ Brilliant Stain Buffer and when do I need it?
    BD Horizon™ Brilliant Stain Buffer is a buffer that reduces non-specific interactions of BD Horizon Brilliant™ Dyes. Its proprietary composition prevents non-specific polymer-to-polymer interactions that can produce artifacts in data. These can occur when two or more BD Horizon™ Brilliant polymer dye-conjugated antibodies (BV, BUV and BB) are in the same staining tube or well. BSB also reduces non-specific interactions between anti-PEG human antibodies present in whole blood.

  2. What is the difference between BD Horizon™ Brilliant Stain Buffer and BD Horizon™ Brilliant Stain Buffer Plus?
    The main difference is how concentrated the buffer is. Standard BSB (Cat. No. 566349) uses 50 μL per test and is appropriate for smaller panels in tube and plate staining protocols. BSB Plus (Cat. No. 566385) uses 10 μL per test and fits volume-constrained applications, such as larger, high dimensional panels.

  3. Do I need BD Horizon™ Brilliant Stain Buffer for compensation controls?
    It is recommended to use BD Horizon™ Brilliant Stain Buffer in your compensation controls and for the same incubation time as panel samples. This applies to all compensation controls, not only Brilliant Dye controls. BSB is compatible with BD™ CompBeads and BD™ SpectraComp™ Beads for bead-based compensation but has not been tested with beads from other vendors. Evaluation of controls prepared without BSB should be performed to confirm generation of acceptable panel compensation or unmixing matrices.

  4. Can I use BD Horizon™ Brilliant Stain Buffer with intracellular staining protocols?
    Yes. If needed you can add BSB during surface staining, before fixation and permeabilization. Then, it can be added again if needed during the intracellular staining step along with BD Perm/Wash™ Buffer as the diluent per your intracellular staining protocol. Use BSB Plus (10 μL per test) instead of the standard BSB (50 μL per test) when total staining volume is a concern.

  5. What could happen if I use BD Horizon Brilliant™ Dyes without Brilliant Stain Buffer?
    The different polymer dyes may interact non-specifically. These dye-dye interactions between Brilliant Dyes can produce artifacts in the analysis. The artifacts typically show up as positive staining on populations that should be negative, similar to when a reagent is undercompensated. This is not due to compensation error and the matrix should not be modified to fix the issue. If you see unexpected staining profiles, these may be addressed by adding BSB to the staining protocol. 

   

   

For Research Use Only. Not for use in diagnostic or therapeutic procedures.