Game 2: Spillover

  1. Spillover

    Fluorescence spillover is the fluorescent signal measured in adjacent, residual and cross-laser detectors. Spectral overlap between fluorochromes can be managed through compensation or spectral unmixing to prevent data artifacts. However, even with compensation and unmixing, spectral overlap of two fluorochromes in a panel can lead to compromised resolution through spillover spreading and unmixing error, making spillover an important consideration in panel design.

    Skip to the Winners


Spillover here is evaluated and ranked based on the analysis of a given fluorochrome’s full emission profile across five lasers.

 

Fluorochromes with less cross-laser excitation are cleaner and will have lower impact on other fluorochromes. We evaluated several fluorochromes primarily excited by the blue laser that have peak emission around 700 nm:

BD Horizon RealBlue™ 705 (RB705)
BD Horizon RealBlue™ 705 (RB705)
BD Horizon Brilliant™ Blue 700 (BB700)
BD Horizon Brilliant™ Blue 700 (BB700)
Bio-Rad StarBright™ Blue 700 (SBB700)
Bio-Rad StarBright™ Blue 700 (SBB700)
BD Pharmingen™ PerCP-Cy5.5
BD Pharmingen™ PerCP-Cy5.5
Thermo Fisher PerCP-eFluor™ 710
Thermo Fisher PerCP-eFluor™ 710 (PerCP-eFluor™ 710)
Thermo Fisher NovaFluor™ Blue 690 (NFB690)
Thermo Fisher NovaFluor™ Blue 690 (NFB690)

Freshly isolated human PBMCs were stained with either BD Horizon RB705 Mouse Anti-Human CD4 SK3 (Cat. No. 570221), BD Pharmingen PerCP-Cy5.5 Mouse Anti-Human CD4 SK3 (Cat. No. 566923), BD Horizon™ BB700 Mouse Anti-Human CD4 SK3 (Cat. No. 566392), Thermo Fisher PerCP-eFluor™ 710 Mouse Anti-Human CD4 SK3, Bio-Rad StarBright Blue 700 Mouse Anti-Human CD4 RPA-T4, or Thermo Fisher NovaFluor™ Blue 690 Anti-Human CD4 SK3 Reagent. Spectral profiles are generated from the positive population with the negative subtracted and are normalized to peak detector. Spillover percentages are dependent on the configuration of an instrument. The rankings were based on analysis on three instruments (BD FACSDiscover S8 Cell Sorter, BD FACSymphony A5 SE Cell Analyzer and Cytek Aurora).  For the data shown, flow cytometry and data analysis were performed using a BD FACSDiscover S8 Cell Sorter and FlowJo Software.

Winner’s Circle

Using normalized emission profiles, winners were determined based on the number of lasers with an additional peak of signal greater than 15% of the main peak signal. RB705 and NFB690 had the least amount of emission into other channels and are therefore declared the winners!

 

PRO TIP: When assigning a fluorochrome to a marker, it is important to consider how spillover spreading may affect resolution of other markers in your panel.

 

Gold Medal Winners

 

Winners:

RB705 and NFB690

 



Explore other games >

Silver Medal Winners

 

Runner-Up:

 BB700

Try the Winning Fluorochrome


Request a sample of RB705

 

*Required fields

Disclaimer: Results and conclusions shown throughout the Fluorochrome Faceoff are based on experiments performed under the conditions described. Users should evaluate reagents with their specific protocols as results may vary with different experimental conditions.


Samples available in participating countries only. Cannot be combined with any other offer. Valid once per user. Offer valid on 25 test/ug size only. There are a limited number of samples available, and BD retains the right to cancel this offer at any time.

    

    

BD flow cytometers are Class 1 Laser Products. For Research Use Only. Not for use in diagnostic or therapeutic procedures.

CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.