The site is undergoing maintenance on
Thursday, September 10, 7:00 pm through Friday, September 11, 3:00 am (CEST), 2026.
If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
See More
The site is undergoing maintenance on
Thursday, September 10, 7:00 pm through Friday, September 11, 3:00 am (CEST), 2026.
If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
See MoreThe site is undergoing maintenance on
Thursday, September 10, 7:00 pm through Friday, September 11, 3:00 am (CEST), 2026
.If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location site or be switched to your location?
Two-color flow cytometric analysis of CD11c expression on C57BL/6 mouse splenic leucocytes. Mouse splenic leucocytes were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with BD Horizon™ BV421 Rat Anti-Mouse I-A/I-E antibody (Cat. No. 562564) and PE Armenian Hamster Anti-Mouse CD11c antibody (Cat. No. 565592) at 0.25 µg/test. The two-color flow cytometric contour plot showing the correlated expression of CD11c versus I-A/I-E was derived from gated events with the forward and side light-scatter characteristics of viable leucocytes. Flow cytometric analysis was performed using a BD FACSCelesta™ Flow Cytometer System. Data shown on this Technical Data Sheet are not lot specific.
Two-color flow cytometric analysis of CD11c expression on C57BL/6 mouse splenic leucocytes. Mouse splenic leucocytes were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with BD Horizon™ BV421 Rat Anti-Mouse I-A/I-E antibody (Cat. No. 562564) and PE Armenian Hamster Anti-Mouse CD11c antibody (Cat. No. 565592) at 0.25 µg/test. The two-color flow cytometric contour plot showing the correlated expression of CD11c versus I-A/I-E was derived from gated events with the forward and side light-scatter characteristics of viable leucocytes. Flow cytometric analysis was performed using a BD FACSCelesta™ Flow Cytometer System. Data shown on this Technical Data Sheet are not lot specific.
Two-color flow cytometric analysis of CD11c expression on C57BL/6 mouse splenic leucocytes. Mouse splenic leucocytes were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with BD Horizon™ BV421 Rat Anti-Mouse I-A/I-E antibody (Cat. No. 562564) and PE Armenian Hamster Anti-Mouse CD11c antibody (Cat. No. 565592) at 0.25 µg/test. The two-color flow cytometric contour plot showing the correlated expression of CD11c versus I-A/I-E was derived from gated events with the forward and side light-scatter characteristics of viable leucocytes. Flow cytometric analysis was performed using a BD FACSCelesta™ Flow Cytometer System. Data shown on this Technical Data Sheet are not lot specific.
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
The N418 monoclonal antibody specifically binds to CD11c, the Integrin alpha X (Integrin αX, Itgax) chain of the heterodimeric gp150, 95 (CD11c/CD18, αXβ2) integrin that forms the complement receptor 4 (CR4). CD11c is a150 kDa type I transmembrane glycoprotein that is expressed on dendritic cells, CD4-CD8+ intestinal intraepithelial lymphocytes (IEL), and some NK cells and T cells. CD11c expression is upregulated on IEL and T cells following activation. Cells of the monocyte/macrophage lineage have been reported to express low levels of CD11c. The CD11c/CD18 integrin can bind to several ligands including iC3b, fibrinogen, and CD54. This integrin reportedly plays important roles in phagocytosis and in mediating cellular interactions during inflammation.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.