Skip to main content Skip to navigation
APC-R700 Mouse IgG1, κ Isotype
Product Details
Down Arrow Up Arrow


BD Horizon™
IgG1, kappa Isotype Control (Anti-KLH)
Mouse BALB/c IgG1, κ
Keyhole limpet hemocyanin (KLH)
Flow cytometry
100 μg/mL
5 μL
RUO (GMP)


657708 Rev. 1
Antibody Details
Down Arrow Up Arrow
X40

The Mouse IgG1 antibody, clone X40, is derived from the hybridization of Sp2/0-Ag 14 mouse myeloma cells with spleen cells from BALB/c mice immunized with KLH.

The antibodies react specifically with keyhole limpet hemocyanin (KLH), an antigen not expressed on human cells or human cell lines.

657708 Rev. 1
Format Details
Down Arrow Up Arrow
APC-R700
The BD Horizon™ APC-R700 (APC-R700) Dye is a part of the BD APC red family of dyes. This tandem fluorochrome is comprised of an Allophycocyanin (APC) dye donor that has excitation maximum (Ex Max) of 651-nm and an acceptor dye, R700, with an emission maximum (Em Max) at 706-nm. APC-R700, driven by BD innovation, is designed to be excited by the red (627–640-nm) laser and detected using an optical filter centered near 710-nm (e.g., a 720/40-nm bandpass filter). APC-R700 is a brighter alternative to Alexa Fluor™ 700. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
APC-R700
Red 627-640 nm
651 nm
706 nm
657708 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "657708" on CiteAb

Development References (3)

  1. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in healthcare settings. MMWR. 1988; 37:377-388. (Biology).
  2. Clinical and Laboratory Standards Institute. 2005. (Biology).
  3. van Vugt MJ, van den Herik-Oudijk IE, van de Winkle JG. Binding of PE-CY5 conjugates to the human high-affinity receptor for IgG (CD64). Blood. 1996; 88(6):2358-2361. (Biology). View Reference
657708 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures. 

 

Although not required, these products are manufactured in accordance with Good Manufacturing Practices.