Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- BD® OMICS-One Protein Panels
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
-
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- BD® OMICS-One Protein Panels
- Belgium (English)
-
Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from United States.
Would you like to stay on the current country site or be switched to your country?
BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1
Clone S33-966 (RUO)

Multicolor flow cytometric analysis of TCF-7/TCF-1 expression by Human lymphocytes or Mouse splenocytes. Bivariate pseudocolor density plots showing TCF-7/TCF-1 expression (or Ig Isotype control staining) versus CD4 were derived from gated events with the side and forward light-scattering characteristics of intact human lymphocytes (upper plots) or mouse splenocytes (lower plots). Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Upper Plots: Human peripheral blood mononuclear cells (PBMC) were fixed and permeabilized with the BD Pharmingen™ Transcription Factor Buffer Set (Cat. No. 562574/562725). The cells were then stained with PE Mouse Anti-Human CD4 antibody (Cat. No. 555347/561844/561843) and either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 566928; Left Plot) or BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1 antibody (Cat. No. 567587; Right Plot) at 0.5 μg/test.
Lower Plots - Mouse splenic leucocytes were similarly fixed and permeabilized. The cells were then stained with BD Horizon™ BUV395 Rat Anti-Mouse CD4 antibody (Cat. No. 740208) and either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Left Plot) or BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1 antibody (Right Plot) at 0.5 μg/test.


Multicolor flow cytometric analysis of TCF-7/TCF-1 expression by Human lymphocytes or Mouse splenocytes. Bivariate pseudocolor density plots showing TCF-7/TCF-1 expression (or Ig Isotype control staining) versus CD4 were derived from gated events with the side and forward light-scattering characteristics of intact human lymphocytes (upper plots) or mouse splenocytes (lower plots). Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Upper Plots: Human peripheral blood mononuclear cells (PBMC) were fixed and permeabilized with the BD Pharmingen™ Transcription Factor Buffer Set (Cat. No. 562574/562725). The cells were then stained with PE Mouse Anti-Human CD4 antibody (Cat. No. 555347/561844/561843) and either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 566928; Left Plot) or BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1 antibody (Cat. No. 567587; Right Plot) at 0.5 μg/test.
Lower Plots - Mouse splenic leucocytes were similarly fixed and permeabilized. The cells were then stained with BD Horizon™ BUV395 Rat Anti-Mouse CD4 antibody (Cat. No. 740208) and either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Left Plot) or BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1 antibody (Right Plot) at 0.5 μg/test.

Multicolor flow cytometric analysis of TCF-7/TCF-1 expression by Human lymphocytes or Mouse splenocytes. Bivariate pseudocolor density plots showing TCF-7/TCF-1 expression (or Ig Isotype control staining) versus CD4 were derived from gated events with the side and forward light-scattering characteristics of intact human lymphocytes (upper plots) or mouse splenocytes (lower plots). Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Upper Plots: Human peripheral blood mononuclear cells (PBMC) were fixed and permeabilized with the BD Pharmingen™ Transcription Factor Buffer Set (Cat. No. 562574/562725). The cells were then stained with PE Mouse Anti-Human CD4 antibody (Cat. No. 555347/561844/561843) and either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Cat. No. 566928; Left Plot) or BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1 antibody (Cat. No. 567587; Right Plot) at 0.5 μg/test.
Lower Plots - Mouse splenic leucocytes were similarly fixed and permeabilized. The cells were then stained with BD Horizon™ BUV395 Rat Anti-Mouse CD4 antibody (Cat. No. 740208) and either BD Horizon™ R718 Mouse IgG1, κ Isotype Control (Left Plot) or BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1 antibody (Right Plot) at 0.5 μg/test.


ImageTitle~BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1

ImageTitle~BD Horizon™ R718 Mouse Anti-TCF-7/TCF-1
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.
Product Notices
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
- Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
- This product is provided under an Agreement between BIOTIUM and BD Biosciences. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
- Alexa Fluor™ is a trademark of Life Technologies Corporation.
- For U.S. patents that may apply, see bd.com/patents.
The S33-966 monoclonal antibody specifically binds to TCF-7 (Transcription factor 7) which is also known as TCF-1 (T-cell factor 1). TCF-7 is a member of the High Mobility Group (HMG) DNA binding protein family of transcription factors. TCF-7 is expressed in thymocytes, T lymphocytes and proliferating epithelial cells. TCF-7 is expressed in the earliest T cell precursors and serves as a critical transcriptional regulator that is involved in the differentiation of thymocytes to become mature T lymphocytes. TCF-7 is necessary for the survival of immature CD4+CD8+ thymocytes. TCF-7 can also promote the differentiation of mature peripheral T cells to become Th2-like cells. TCF-7 may also function as a transcriptional repressor of certain target genes including CTNNB1 and TCF7L2. The S33-966 antibody crossreacts with human TCF-7.

Development References (5)
-
Chen Z, Ji Z, Ngiow SF, et al. TCF-1-Centered Transcriptional Network Drives an Effector versus Exhausted CD8 T Cell-Fate Decision.. Immunity. 2019; 51(5):840-855.e5. (Clone-specific: Flow cytometry). View Reference
-
Germar K, Dose M, Konstantinou T, et al. T-cell factor 1 is a gatekeeper for T-cell specification in response to Notch signaling. Proc Natl Acad Sci U S A. 2011; 108(50):20060-20065. (Biology). View Reference
-
Johnson JL, Georgakilas G, Petrovic J, et al. Lineage-Determining Transcription Factor TCF-1 Initiates the Epigenetic Identity of T Cells.. Immunity. 2018; 48(2):243-257.e10. (Clone-specific: Flow cytometry). View Reference
-
Weber BN, Chi AW, Chavez A, et al. A critical role for TCF-1 in T-lineage specification and differentiation. Nature. 2011; 476(7358):63-68. (Biology). View Reference
-
Yu Q, Sharma A, Oh SY, et al. T cell factor 1 initiates the T helper type 2 fate by inducing the transcription factor GATA-3 and repressing interferon-γ. Nat Immunol. 2009; 10(9):992-999. (Biology). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.