BUV395 Mouse Anti-Human HLA-DP

BD OptiBuild™ BUV395 Mouse Anti-Human HLA-DP

Clone B7/21 (also known as B7/21.49; B7/21 (IgG1))

(RUO)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
HLADP; HLA-DPαβ; DPA and DPB; DPα and DPβ; DPαβ
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Human NALM6 Leukemia Cells
Flow cytometry (Qualified)
0.2 mg/ml
AB_2874962
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD CompBead to ensure that BD CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Product Notices

  1. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  7. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. BD Horizon Brilliant Ultraviolet 395 is covered by one or more of the following US patents: 8,158,444; 8,575,303; 8,354,239.
750866 Rev. 2
Antibody Details
Down Arrow Up Arrow
B7/21

The B7/21 monoclonal antibody specifically recognizes HLA-DP antigens which are human Major Histocompatibility Complex (MHC) Class II antigens. HLA-DP antigens are heterodimers comprised of two different type I transmembrane glycoproteins that are noncovalently-associated. The ~34 kDa HLA-DP alpha (HLA-DPα) and ~26-28 kDa HLA-DP beta (HLA-DPβ) chains are encoded by HLA-DPA1 and HLA-DPB1 genes, respectively, that are located within the Human Leukocyte Antigen (HLA) Complex of chromosome 6. The B7/21 antibody recognizes a monomorphic determinant present on cells expressing HLA-DP1, -DP2, -DP3, -DP4, and -DP5 and does not reportedly bind to HLA-DR or HLA-DQ Class II antigens. HLA-DP is variably expressed on B cells, monocytes, macrophages, dendritic cells (DC), activated T cells, and tumor cell lines including B cell lines, myelomas, and some myeloid leukemias. HLA-DP functions in the presentation of peptides derived from extracellular antigens to CD4+ T cells.

       The original B7/21 hybridoma was derived from hybridization of mouse 5194/SXXOBU1 myeloma cells with spleen cells from BALB/c mice immunized with NALM6 human leukemia cells and secreted IgG3, κ antibody. An immunoglobulin switch-variant B7/21 hybridoma, also known as B7/21.49 or B7/21 (IgG1), was subsequently isolated that secreted lgG1 antibody with the same specificity as the original IgG3 antibody. The purified switch-variant B7/21 IgG1 antibody blocks the staining of HLA-DP-positive cells by fluorescent B7/21 IgG3 antibody.  The B7/21 IgG1 antibody is reportedly not cytotoxic in the presence of complement.

The antibody was conjugated to BD Horizon™ BUV395 which is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This dye has been exclusively developed by BD Biosciences to have minimal spillover into other detectors, making it an optimal choice for multicolor flow cytometry. With an Ex Max at 348 nm and an Em Max at 395 nm, BD Horizon BUV395 can be excited with a 355 nm laser and detected with a 379/28 filter.

750866 Rev. 2
Format Details
Down Arrow Up Arrow
BUV395
The BD Horizon Brilliant™ Ultraviolet 395 (BUV395) Dye is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This base dye is a polymer fluorochrome with an excitation maximum (Ex Max) of 348-nm and an emission maximum (Em Max) at 395-nm. Driven by BD innovation, BUV395 is designed to be excited by the ultraviolet laser (355-nm) and detected using an optical filter centered near 380-nm (e.g., 379/28-nm bandpass filter). BUV395 is the ideal dye when using only one detector on the ultraviolet laser as it spills into no other detectors and no other fluors spill into it. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BUV395
Ultraviolet 355 nm
348 nm
395 nm
750866 Rev.2
Citations & References
Down Arrow Up Arrow
View product citations for antibody "750866" on CiteAb

Development References (2)

  1. Lennon-Duménil AM, Barbouche MR, Vedrenne J, et al. Uncoordinated HLA-D gene expression in a RFXANK-defective patient with MHC class II deficiency.. J Immunol. 2001; 166(9):5681-7. (Clone-specific). View Reference
  2. Strobl H, Bello-Fernandez C, Riedl E, et al. flt3 ligand in cooperation with transforming growth factor-beta1 potentiates in vitro development of Langerhans-type dendritic cells and allows single-cell dendritic cell cluster formation under serum-free conditions.. Blood. 1997; 90(4):1425-34. (Clone-specific). View Reference