Expression of IL-6 by stimulated CD14+ human monocytes. Human PBMC were stimulated for 6 hours with LPS (100 ng/ml final concentration) in the presence of GolgiStop™ (2 µM final concentration; Cat. No. 554724). The PBMC were harvested, stained with PE-mouse anti-human CD14 monoclonal antibody (PE-M5E2, Cat. No. 555398), fixed, permeabilized, and subsequently stained with either 0.25 µg of FITC-Rat IgG1 isotype control immunoglobulin (FITC-R3-34; Cat. No. 554684; middle panel) or with 0.25 µg of FITC-rat anti-human IL-6 antibody (FITC-MQ2-13A5; Cat. No. 554544; right panel), following Pharmingen's staining protocol. Left panel portrays autofluorescence detected by the FL1 PMT versus CD14-PE staining. The data reflect gating on monocytes, based on forward and side scattered light signals. To demonstrate specificity of staining, the binding by FITC-MQ2-13A5 antibody was blocked by each of the following: 1) preincubation of the fluorochrome-conjugated antibody with recombinant human IL-6 (Cat. No. 550071; data not shown) and by 2) preincubation of the fixed/permeabilized cells with unlabeled MQ2-13A5 antibody (Cat. No. 554542; data not shown) prior to staining. The quadrant markers for the bivariate dot plots were set based on the autofluorescence controls and verified using the ligand blocking and unlabeled antibody blocking specificity controls.
BD Pharmingen™ FITC Rat IgG1, κ Isotype Control
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
Recommended Assay Procedure:
The FITC-, PE- and APC-conjugated R3-34 immunoglobulins (Cat. No. 554684; 554685; 554686) are suitable rat IgG1 isotype controls for assessing the level of background staining on paraformaldehyde-fixed/saponin-permeabilized mouse and human cells for flow cytometric analysis. Use at comparable concentrations to antibody of interest (e.g., ≤ 0.5 µg antibody/1 million cells (see image, right panel). For specific methodology, see online protocols or chapter 4 on intracellular staining in Techniques for Immune Function Analysis Application Handbook 1st Edition, both of which are located at our website at www.bdbiosciences.com. The intracellular cytokine staining technique and use of blocking controls are described in detail by C. Prussin and D. Metcalfe.
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
Following immunization of a rat with mouse immunoglobulin (Ig), the Ig from the R3-34 hybridoma was identified as a non-reactive clone. The R3-34 immunoglobulin was selected as an Ig isotype control following screening for low background staining on a variety of mouse and human cells and tissues.
This antibody is routinely tested by flow cytometric analysis. Other applications were tested at BD Biosciences Pharmingen during antibody development only or reported in the literature.
Development References (1)
-
Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Methodology: IC/FCM Block). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.