Skip to main content Skip to navigation
PE Mouse Anti-Human IL-22
PE Mouse Anti-Human IL-22
Multicolor flow cytometric analysis of IL-22 expression in human peripheral blood mononuclear cells (PBMCs). PBMCs were cultured in complete tissue culture medium with Phorbol 12-Myristate 13-Acetate (PMA; Sigma, 50 ng/ml) and Ionomycin (Sigma, 500 ng/ml) in the presence of BD GolgiPlug™ Protein Transport Inhibitor (Cat. No. 555029) for 6 hours. The cells were harvested, then fixed and permeabilized using BD Cytofix™ Fixation Buffer (Cat. No. 554655) and BD Perm/Wash™ buffer (Cat. No. 554723). The cells were then stained with BD Horizon™ BUV395 Mouse Anti-Human CD4 (Cat. No. 564724) and either PE Mouse IgG2a, κ Isotype Control (Cat. No. 558595; Left Panel) or PE Mouse Anti-IL-Human 22 antibody (Cat. No. 567563/567564; Right Panel) at 0.06 µg/test. Bivariate pseudocolor density plots showing the correlated expression of IL-22 (or Ig Isotype control staining) versus CD4 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD X-20 LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Multicolor flow cytometric analysis of IL-22 expression in human peripheral blood mononuclear cells (PBMCs). PBMCs were cultured in complete tissue culture medium with Phorbol 12-Myristate 13-Acetate (PMA; Sigma, 50 ng/ml) and Ionomycin (Sigma, 500 ng/ml) in the presence of BD GolgiPlug™ Protein Transport Inhibitor (Cat. No. 555029) for 6 hours. The cells were harvested, then fixed and permeabilized using BD Cytofix™ Fixation Buffer (Cat. No. 554655) and BD Perm/Wash™ buffer (Cat. No. 554723). The cells were then stained with BD Horizon™ BUV395 Mouse Anti-Human CD4 (Cat. No. 564724) and either PE Mouse IgG2a, κ Isotype Control (Cat. No. 558595; Left Panel) or PE Mouse Anti-IL-Human 22 antibody (Cat. No. 567563/567564; Right Panel) at 0.06 µg/test. Bivariate pseudocolor density plots showing the correlated expression of IL-22 (or Ig Isotype control staining) versus CD4 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD X-20 LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
interleukin-22; IL-10-related T-cell-derived inducible factor; IL-TIF; ILTIF; IL-22a, ilTIFa; Iltif; TIFa
Human (QC Testing), Mouse (Tested in Development)
Mouse BALB/c IgG2a, κ
Human IL-22 Recombinant Protein
Intracellular staining (flow cytometry) (Routinely Tested)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
Antibody Details
Down Arrow Up Arrow
MH22B2

The MH22B2 monoclonal antibody specifically recognizes human Interleukin-22 (IL-22), which is encoded by the IL22 gene. Cross-reactivity of MH22B2 mAb to mouse IL-22 (which shares 79% amino acid identity with human IL-22) has been observed by ELISA and by flow cytometry of HEK293 cells transfected with mouse IL-22 and TH17-differentiated CD4-positive T cells from C57BL/6 mice. IL-22 (with or without other cytokines) is secreted by many T-cell and innate-lymphoid-cell populations. Evidence that IL-22 plays a key role in mucosal immunity includes the restricted expression of the alpha subunit of the heterodimeric IL-22 receptor, called IL-22R1, on epithelial cells and cells of epithelial origin. At epithelial surfaces, IL-22 elicits antimicrobial defenses and maintains epithelial integrity. Alternatively, uncontrolled IL-22 production can result in certain inflammatory disorders. Regulation of IL-22 expression is complex, involving other cytokines (eg, IL-6, IL-23, and TGF-β) and many transcription factors, (eg, AHR, c-Maf, STAT3, RORɤT, BATF, and others).

Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
Citations & References
Down Arrow Up Arrow

Development References (8)

  1. Colonna M. Interleukin-22-producing natural killer cells and lymphoid tissue inducer-like cells in mucosal immunity.. Immunity. 2009; 31(1):15-23. (Biology). View Reference
  2. Le-Thi-Phuong T, Dumoutier L, Renauld JC, Van Snick J, Coutelier JP. Divergent roles of IFNs in the sensitization to endotoxin shock by lactate dehydrogenase-elevating virus.. Int Immunol. 2007; 19(11):1303-11. (Clone-specific: ELISA). View Reference
  3. Martin B, Hirota K, Cua DJ, Stockinger B, Veldhoen M. Interleukin-17-producing gammadelta T cells selectively expand in response to pathogen products and environmental signals.. Immunity. 2009; 31(2):321-30. (Clone-specific: Flow cytometry). View Reference
  4. Rutz S, Eidenschenk C, Ouyang W. IL-22, not simply a Th17 cytokine.. Immunol Rev. 2013; 252(1):116-32. (Biology). View Reference
  5. Suurmond J, Habets KL, Dorjée AL, Huizinga TW, Toes RE. Expansion of Th17 Cells by Human Mast Cells Is Driven by Inflammasome-Independent IL-1β. J Immunol. 2016; 164(11):4473-4481. (Biology). View Reference
  6. Trifari S, Kaplan CD, Tran EH, Crellin NK, Spits H. Identification of a human helper T cell population that has abundant production of interleukin 22 and is distinct from T(H)-17, T(H)1 and T(H)2 cells.. Nat Immunol. 2009; 10(8):864-71. (Biology). View Reference
  7. Veldhoen M, Hirota K, Westendorf AM, et al. The aryl hydrocarbon receptor links TH17-cell-mediated autoimmunity to environmental toxins.. Nature. 2008; 453(7191):106-9. (Immunogen: Flow cytometry). View Reference
  8. Zenewicz LA. IL-22: There Is a Gap in Our Knowledge.. Immunohorizons. 2018; 2(6):198-207. (Biology). View Reference
View All (8) View Less

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.