-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- BD® OMICS-One Protein Panels
- BD OMICS-One™ WTA Next Assay
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location site or be switched to your location?
Overview
The BD OneFlow™ BCP-ALL T1 is part of the standardized BD OneFlow™ Solution, a comprehensive set of reagents, setup beads, protocols and assay templates to reproducibly set up the flow cytometer and stain, acquire and analyze patient specimens for immunophenotyping of normal and aberrant cell populations. It is built on the research and validation work of the EuroFlow™ Consortium on the characterization of hematological malignancies for improved accurate diagnosis.1
The BD OneFlow™ BCP-ALL T1 is intended for flow-cytometric immunophenotyping of mature and immature hematopoietic cells populations (lymphoid lineage) in bone marrow and peripheral blood. It is used as an aid in the differential diagnosis of hematologically abnormal patients, including pediatric patients, having or suspected of having, B-cell acute lymphoblastic leukemia.
Features
The BD OneFlow™ BCP-ALL T1
- Is a pre-configured single-use, 8-color reagent
- Is available in a 10 test/box size, two pouches, of five ready-to-use tubes each
- Is specifically designed for the classification of B-cell acute lymphoblastic leukemia and can be used in combination with BD OneFlow™ ALOT orientation tube
- Boxes, pouches and tubes are color coded with orange bands for easy identification.
The BD OneFlow™ Reagents increase efficiency by simplifying instrument standardization, reducing the time to prepare the instrument as well as the technical burden and training needs.2
For BD FACSLyric™ Flow Cytometer Users:
- Instrument set-up hands-on time is less than 30 minutes annually and daily setup time for operator is less than 10 minutes
- BD® CS&T IVD Beads standardize setup and monitoring for consistent performance and ensure reproducibility through Universal Setup
- BD® FC Beads (7-Color, 5-Color and 2-Color Kits) support consistency of results, eliminating the need for using cells for compensation
- BD® CS&T Beads and BD® FC Beads kits necessary for instrument setup and compensation can be used for other BD CE-IVD assays on the BD FACSLyric™ Flow Cytometer
BD OneFlow™ Acute B-cell Leukemia Panel increases efficiency by reducing time for preliminary set-up and antibody cocktailing
- In a comparative study between traditional liquid antibodies and BD OneFlow™, the setup for liquid reagents involved multiple manual steps including assembling materials, preparing specimens, labeling vials, and pipetting pre-titered volumes of each antibody to create cocktails.
- The BD OneFlow™ BCP-ALL Tube 1 simplifies this process, delivering
- Up to 81% savings in hands-on time during preliminary setup and antibody cocktailing.
- Up to 94% reduction in error-prone steps, improving consistency and reliability compared to liquid antibody preparation.
The BD OneFlow™ Acute B-cell Leukemia Panel Has a High Diagnostic Accuracy (specificity) and Sensitivity
A comparison between clinical performance of the BD OneFlow™ Acute B-cell Leukemia Panel on the BD FACSLyric™ Flow Cytometer and final clinical diagnosis demonstrated:
- High specificity (through identification of BCP-ALL negative specimens) in 98.7% and 99.1% of the cases as analyzed by two independent experts*,¤
- High sensitivity (through detection of BCP-ALL positive specimens) in 94.8% and 100% of cases as analyzed by two independent experts *,¤
* A clinical performance evaluation between the BD OneFlow™ system on the BD FACSLyric™ Flow Cytometer and the final clinical diagnosis was performed at seven clinical sites. The results were analyzed by two independent experts in leukemia and lymphoma immunophenotyping who did not know the final clinical diagnosis. The final clinical diagnosis was performed according to World Health Organization (WHO) guidelines. The clinical history, complete blood count, morphological assessment, flow cytometry, histopathology, molecular genetic findings, and other laboratory data were taken into consideration
¤ Based on exploratory analysis
| Expert | Metrics | Value | Clopper-Pearson 95% CI | Wilson Score 95% CI |
|---|---|---|---|---|
| Expert #1 | Sensitivity | 94.8% | 85.6%, 98.9% | 85.9%, 98.2% |
| Specificity | 98.7% | 96.2%, 99.7% | 96.2%, 99.6% | |
| Expert #2 | Sensitivity | 100.0% | 93.8%, 100.0% | 93.8%, 100.0% |
| Specificity | 99.1% | 96.9%, 99.9% | 96.9%, 99.8% |
The BD OneFlow™ BCP-ALL T1 reagent composition
A full description of the utility of the antibodies chosen for the BD OneFlow™ BCP-ALL T1 is provided in the publication by the EuroFlow Consortium.1
Acquisition and analysis in BD FACSuite™ Clinical Application
- Standardised acquisition and analysis in BD FACSuite™ Clinical Application with predefined templates for consistency of results
- Supplemental analysis reports for flexibility in examining additional cell populations
- Reports available in 25 languages
-
Brochure
-
Application Guide
-
Instruction for Use
Other reagents belonging to the BD OneFlow™ Solution are:
References:
- van Dongen JJM, Lhermitte L, Böttcher S, et al. on behalf of the EuroFlow Consortium (EU-FP6, LSHB-CT-2006-018708). EuroFlow antibody panels for standardized n-dimensional flow cytometric immunophenotyping of normal, reactive and malignant leukocytes. Leukemia. 2012;26(9): 1908-1975. doi: 10.1038/leu.2012.120
- Moloney E, Watson H, Barge D, et al. Efficiency and health economic evaluations of BD OneFlow™ Flow Cytometry Reagents for diagnosing chronic lymphoid leukemia. Cytometry B Clin Cytom. 2019;96(6):514-520. doi: 10.1002/cyto.b.21779
The BD FACSLyric™ Flow Cytometer with the BD FACSuite™ Clinical and BD FACSuite™ Applications are an in vitro diagnostic medical device bearing a CE mark.
The BD OneFlow™ LST , BD OneFlow™ B-CLPD T1, BD OneFlow™ PCST, BD OneFlow™ PCD, BD OneFlow™ ALOT, BD OneFlow™ AML T1, BD OneFlow™ AML T2, BD OneFlow™ AML T3, BD OneFlow™ AML T4, BD OneFlow™ BCP-ALL T1 are in vitro diagnostic medical device bearing a CE mark and are CE certified by BSI Group the Netherlands B.V.
(Notified Body Number = 2797).
BD Flow Cytometers are Class 1 Laser Products.
The EuroFlow trademark is the property of the EuroFlow Consortium and cannot be reproduced or published without prior written permission from the EuroFlow coordinator (www.euroflow.org).