Skip to main content Skip to navigation
BV480 Mouse Anti-Human CD243
Product Details
Down Arrow Up Arrow


BD OptiBuild™
ABCB1; ABC20; CLCS; GP170; MDR1; P-GP; PGY1
Human (Tested in Development)
Mouse BALB/c IgG2a, κ
Human MDR1 Transfected Cell Line
Flow cytometry (Qualified)
0.2 mg/ml
VII 70364
AB_2743698
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV480 under optimal conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).

Product Notices

  1. This antibody was developed for use in flow cytometry.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Researchers should determine the optimal concentration of this reagent for their individual applications.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. BD Horizon Brilliant Violet 480 is covered by one or more of the following US patents: 8,575,303; 8,354,239.
746382 Rev. 1
Antibody Details
Down Arrow Up Arrow
UIC2

The UIC2 monoclonal antibody specifically binds to an extracellular epitope of CD243, which is also known as ATP-binding cassette subfamily B member 1 (ABCB1), Multidrug resistance protein 1 (MDR1), or P-glycoprotein 1. CD243 is a transmembrane glycoprotein that spans the membrane 12 times. CD243 acts as an ATP-dependent efflux pump for a large variety of lipophilic molecules and drugs. This efflux activity has been suggested to lead to resistance to the drugs used in chemotherapy. CD243 is expressed by epithelial and endothelial cells, and at low levels by T cells, B cells, NK cells, and hematopoietic stem cells. It may be expressed at high levels by multidrug resistant (MDR) tumor cells. The UIC2 antibody reportedly inhibited the efflux of CD243 substrates from MDR cells and increased the cytotoxicity of certain CD243-transported drugs. The UIC2 antibody reportedly does not crossreact with mouse CD243.

The antibody was conjugated to BD Horizon™ BV480 which is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 436-nm and Em Max at 478-nm, BD Horizon BV480 can be excited by the violet laser and detected in the BD Horizon BV510 (525/40-nm) filter set.  BV480 has less spillover into the BV605 detector and, in general, is brighter than BV510.

746382 Rev. 1
Format Details
Down Arrow Up Arrow
BV480
The BD Horizon Brilliant Violet™ 480 (BV480) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This polymer-technology fluorochrome has an excitation maximum (Ex Max) of 440-nm and an emission maximum (Em Max) of 479-nm. Driven by BD innovation, BV480 is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 480-nm (e.g., a 525/50 bandpass filter). The increased fluorescence intensity of BV480 and narrower emission spectra, make it a good alternative for BV510 or V500. Due to its excitation profile, BV480 will also has less cross-laser excitation with the UV laser, resulting in less spillover into UV channels compared to BV510. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV480
Violet 405 nm
440 nm
479 nm
746382 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "746382" on CiteAb

Development References (5)

  1. Mechetner EB1, Roninson IB. Efficient inhibition of P-glycoprotein-mediated multidrug resistance with a monoclonal antibody.. Proc Natl Acad Sci U S A. 1992; 89(13):5824-5828. View Reference
  2. Nagy H, Goda K, Arceci R, Cianfriglia M, Mechetner E, Szabó G. P-Glycoprotein conformational changes detected by antibody competition.. Eur J Biochem. 2001; 268(8):2416-20. View Reference
  3. Ritchie TK, Kwon H, Atkins WM. Conformational analysis of human ATP-binding cassette transporter ABCB1 in lipid nanodiscs and inhibition by the antibodies MRK16 and UIC2.. J Biol Chem. 2011; 286(45):39489-96. View Reference
  4. Szalóki G, Krasznai ZT, Tóth Á, et al. The strong in vivo anti-tumor effect of the UIC2 monoclonal antibody is the combined result of Pgp inhibition and antibody dependent cell-mediated cytotoxicity.. PLoS ONE. 2014; 9(9):e107875. View Reference
  5. Zhou Y, Gottesman MM, Pastan I. The extracellular loop between TM5 and TM6 of P-glycoprotein is required for reactivity with monoclonal antibody UIC2.. Arch Biochem Biophys. 1999; 367(1):74-80. View Reference
View All (5) View Less
746382 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.