The site is undergoing maintenance on
Friday, September 11, 2:00 am through Saturday, September 12, 2:00 am (CEST), 2026.
If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
See More
The site is undergoing maintenance on
Friday, September 11, 2:00 am through Saturday, September 12, 2:00 am (CEST), 2026.
If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
See MoreThe site is undergoing maintenance on
Friday, September 11, 2:00 am through Saturday, September 12, 2:00 am (CEST), 2026
.If you encounter problems while ordering, please contact us at BDBCustomerService@bd.com
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location site or be switched to your location?
Human immunodeficiency virus (HIV) targets the immune system, and if untreated, causes acquired immune deficiency syndrome (AIDS). Around the world, 38 million individuals are currently living with HIV. Of those, 1.7 million people were newly infected in 2019 and 690,000 have died of AIDS-related illnesses.1 Two main types of HIV exist—HIV-1 and HIV-2. They are very similar structurally and both ultimately lead to AIDS. Globally, HIV-1 is more widespread while HIV-2 is restricted to Western and Central Africa. HIV-2 is less virulent with a longer progression into AIDS but induces diseases of the central nervous system more frequently.
Assuming no treatment is taken, there are three stages in the progression of HIV infection:2
The World Health Organization (WHO) defines four clinical stages of HIV disease—stage 1 through 4, based on the severity of symptoms and coinfections and progression to AIDS.
For adults, adolescents and children older than five years, advanced HIV disease is defined as having a CD4 T-cell count <200 cells/mm3 or WHO stage 3 or 4 event. All children younger than 5 years old with HIV are considered as having advanced HIV disease.3
Antibody tests are the most widely used diagnostic tests to detect HIV infection. It can take about 28 days post-exposure (window period) for HIV-specific antibodies to be detected. Nucleic acid tests (NAT) help determine the viral load in patients. The 2015 World Health Organization (WHO) “Clinical Guidelines: HIV Diagnosis” provides diagnostic test recommendations for different patient groups.4
HIV is a retrovirus with a genome of 9.8 kilobases coding for a very small number of proteins and with a high mutation rate. The lipid envelope surrounding the core is derived from host cells and is studded with glycoproteins, which are of paramount importance during infection and for eliciting immunogenicity. The envelope protein gp120 binds to CD4 to fuse with T-cells and macrophages. Upon entry into the host cell, the viral RNA is reverse transcribed to DNA, which then integrates into the host genome and gets replicated using the hijacked host machinery. This results in the activation of immune responses instantly, resulting ultimately in depletion of the CD4+ T-cell population through various mechanisms.5
HIV-mediated CD4+ T-cell depletion is believed to occur through several stages—(i) enhanced T-cell production upon infection, (ii) accelerated destruction of T-cells through immune responses, (iii) accelerated T-cell production as a response to T-cell depletion through cytokine signaling in the lymph nodes, (iv) accelerated viral replication resulting in the destruction of progenitor cells in the bone marrow, thymus and peripheral lymphoid systems.6
Mechanisms of HIV-mediated CD4+ T-cell depletion. (Image adapted from McCune, 2001).6
Interested in preparing for the IVDR? Visit our IVDR page to learn more about the measures you can take to prepare your lab.
Viral load monitoring and CD4 T-cell count are routinely used for HIV monitoring. CD4 T-cell count measurements are critical for gaining insights into HIV disease progression and patient prognosis.1,2
Flow cytometry is a standard technique used for determining CD4 counts as it provides accuracy, precision and reproducibility. Flow cytometry also provides high-throughput capabilities. Both percentage CD4+ T-lymphocytes among lymphocytes and absolute lymphocyte counts can be determined using flow cytometry. Dual-platform approaches for determining CD4 counts use a flow cytometer for generating percentage CD4+ T-lymphocytes and a hematological analyzer for enumerating absolute lymphocyte counts. Single-platform approaches determine CD4 counts without using a hematological analyzer by either directly counting the number of CD4+ T-lymphocytes in a given volume of blood by CD45 gating3 or by adding microbeads to a known volume of CD4-stained blood samples.4 Determining percentages or counts of CD3+CD4+ lymphocytes can be useful in monitoring HIV-infected individuals.5 Individuals with HIV typically exhibit a steady decrease of CD3+CD4+ lymphocyte counts as the infection progresses.6 At the final stages of infection, CD4 counts are less than 200 CD4/µL3, resulting in severe immunodeficiency. 7
Using adoptive transfer of co-stimulated CD4+ T-cells for reconstituting CD4+ helper T-cell activity has been demonstrated to be a possible method to augment natural immunity to HIV-1 infection.8 HIV-mediated immunosuppression could also result in patients becoming more prone to frequent and severe infections. Opportunistic infections leading to diseases such as Pneumocystis pneumonia (PCP), toxoplasma encephalitis, cytomegalovirus (CMV) infections and tuberculosis are hallmarks of AIDS.9
The 2016 World Health Organization (WHO) “Consolidated Guidelines on the Use of Antiretroviral Drugs for Treating and Preventing HIV Infection” recommend starting ART regardless of CD4 T-cell count and that the use of CD4 T-cell count for ART response monitoring can be stopped in settings where routine viral load monitoring is available and people are stable on ART.10 However, CD4 T-cell count testing at baseline for all people living with HIV remains important. Relying on clinical staging alone risks missing substantial numbers of people living with HIV with severe immune suppression.
BD Biosciences offers various clinical CD4 testing solutions to help manage HIV patients. The solutions range from a small portable cytometry imaging and absorbance spectrometer system to a fully automated clinical flow cytometer.
BD FACSPresto™ Near-Patient CD4 Counter, an imaging cytometry system with an absorbance spectrometer, along with the BD FACSPresto™ Cartridge, is designed to provide absolute and percentage results of CD4 T-lymphocytes and total Hb concentration in whole blood samples. The system is portable, easy to use and provides CD4 results and Hb concentration in 22 minutes.
The BD FACSLyric™ Flow Cytometer is a clinical cell analyzer that offers high sensitivity, automation and standardization.
BD Multitest™ Reagents, the BD Multitest™ 4-Color Reagent and BD Multitest™ 6-Color TBNK Reagent, formulated to be used with BD Trucount™ Tubes, provide absolute counting capability.
BD FACSuite™ Clinical Application, with predefined templates for BD Multitest™ 4-Color Reagent and BD Multitest™ 6-Color TBNK Reagent analysis, provides reproducible and consistent results. Each reagent includes a cocktail of multiple fluorescently labeled monoclonal antibodies, premixed at the appropriate titer to ensure quality staining.
A streamlined methodology for CD4 cell analysis using the BD FACSLyric™ Flow Cytometry System.
The BD FACSLyric™ Flow Cytometer with the BD FACSuite™ Clinical and BD FACSuite™ applications are CE marked in compliance with the European In Vitro Diagnostic Medical Device Directive 98/79/EC.
The BD Multitest™ 6-Color TBNK Reagent with optional BD Trucount™ Tubes is intended for use with the BD FACSLyric™ and BD FACSCanto™ II Flow Cytometers to determine the percentages and absolute counts of the following mature human lymphocyte subsets in peripheral whole blood for immunophenotyping
T-lymphocytes (CD3+)
B-lymphocytes (CD19+)
Natural killer (NK) lymphocytes (CD3–CD16+ and/or CD56+)
Helper/inducer T-lymphocytes (CD3+CD4+)
Suppressor/cytotoxic T-lymphocytes (CD3+CD8+)
This reagent can be used to characterize and monitor some forms of immunodeficiency and autoimmune disease.
BD Trucount™ Tubes are used for determining absolute counts of leucocytes in blood. BD Trucount™ Tubes are designed for use with in vitro diagnostic products such as BD Tritest™ Reagents and a suitably equipped flow cytometer.
BD Trucount™ Tubes can be used with the BD FACS™ Loader.
![]()
BD FACS™ Loader, BD Multitest™ and BD Tritest™ products as intended on this page, BD Trucount™ Tubes, BD FACSPresto™ Near-Patient CD4 Counter, BD FACSPresto™ Cartridge, BD FACSCanto™ II Flow Cytometer and BD FACSLyric™ Flow Cytometer with the BD FACSuite™ Clinical and BD FACSuite™ applications are in vitro diagnostic medical devices bearing a CE mark.
BD Flow Cytometers are Class 1 Laser Products.
BD FACSPresto™ Near-Patient CD4 Counter System is for point of care use.