Skip to main content Skip to navigation
Biotin Mouse Anti-Human IL-15
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Human (QC Testing)
Mouse IgG1
Recombinant Human IL-15
ELISA Detection (Routinely Tested)
0.5 mg/ml
3600
AB_395525
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with biotin under optimum conditions, and unreacted biotin was removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

ELISA Detection: The biotinylated G243-886 antibody (Cat. No. 554713) is useful as a detection antibody for a sandwich ELISA for measuring human IL-15 protein levels. Biotinylated G243-886 antibody can be paired with the purified G243- 935 antibody (Cat. No. 554712) as the capture antibody, with recombinant human IL-15 (Cat. No. 560254) as the standard. Biotinylated mouse anti-human IL-15 antibody should be titrated (0.5 - 2.0 µg/ml) to determine optimal concentration for ELISA detection. To obtain linear standard curves, doubling dilutions of human IL-15 ranging from ~2,000 to 15 pg/ml are recommended for inclusion in each ELISA plate. For specific methodology, please visit our web site, www.bdbiosciences.com, and go to the protocols section or the chapter on ELISA in the Immune Function Handbook.

This ELISA pair shows no cross-reactivity with any of the cytokines tested (e.g., mouse IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-9, IL-10, IL-12 p70, IL-15, GM-CSF, IFN-γ, MCP-1, TCA-3, TNF; human IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, G-CSF, GM-CSF, IFN-γ, lymphotactin, MCP-1, MCP-2, MIP-1α, MIP-1β, NT-3, PDGF-AA, sCD23 , SCF, TNF, LT-α, VEGF; rat IL-2, IL-4, IL-6, IL-10, GM-CSF, IFN-γ, TNF).

This ELISA pair is recommended primarily for measuring cytokine from experimental cell culture systems. These ELISA reagents are not recommended for assaying serum or plasma samples. For measuring Human IL-15 in serum or plasma our Human IL- 15 BD OptEIA™ set (Cat. No. 559268) is specially formulated and recommended.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
554713 Rev. 2
Antibody Details
Down Arrow Up Arrow
G243-886

The G243-886 antibody reacts with human interleukin-15 (IL-15). The immunogen used to generate the G243-886 hybridoma was recombinant human IL-15.

554713 Rev. 2
Format Details
Down Arrow Up Arrow
Biotin
Biotin is a ubiquitous co-factor (also known as Vitamin B7) that has many properties that make it extremely useful for molecular biology. Biotin has an extremely high affinity for the Avidin family of proteins (Kd = 10-15 M), making it the perfect tool to link two molecules. Biotin labeled antibodies can be combined with any number of Avidin-conjugated probes in order to customize an assay to a particular need. This is especially useful in the case of magnetic cell separation using streptavidin/magnetic bead conjugates, or in the case of flow cytometry using streptavidin/fluorophore conjugates.
Biotin
554713 Rev.2
Citations & References
Down Arrow Up Arrow
View product citations for antibody "554713" on CiteAb
No Citations Found

No Citations are available for this Product

554713 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.