Skip to main content Skip to navigation
Alexa Fluor™ 488 Rat Anti-Mouse CD34
Alexa Fluor™ 488 Rat Anti-Mouse CD34
Multiparameter analysis of of CD34+ and CD34- subpopulations of mouse bone marrow hematopoietic progenitor cells. BALB/c mouse bone marrow cells were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with either Alexa Fluor™ 488 Rat IgG2a, κ Isotype Control (Cat. No. 557676; Left Plot) or Alexa Fluor™ 488 Mouse CD34 antibody (Cat. No. 567135; Right Plot) at 2 µg/test followed by staining with a cocktail of BD Horizon™ BV421-conjugated antibodies specific for CD3e (Cat. No. 562600), CD11b (562605), CD45R/B220 (562922), TER-119/Erythroid Cells (563998), and Ly-6G and Ly-6C (562709), markers that identified major lineage-committed cell types. BD Via-Probe™ Cell Viability 7-AAD Solution (Cat. No. 555815/555816) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of CD34 (or Ig Isotype control staining) versus the Lineage Cocktail of Markers was derived from gated events with the forward and side light-scatter characteristics of viable (7-AAD negative) bone marrow cells. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Multiparameter analysis of of CD34+ and CD34- subpopulations of mouse bone marrow hematopoietic progenitor cells. BALB/c mouse bone marrow cells were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) (Cat. No. 553141/553142). The cells were then stained with either Alexa Fluor™ 488 Rat IgG2a, κ Isotype Control (Cat. No. 557676; Left Plot) or Alexa Fluor™ 488 Mouse CD34 antibody (Cat. No. 567135; Right Plot) at 2 µg/test followed by staining with a cocktail of BD Horizon™ BV421-conjugated antibodies specific for CD3e (Cat. No. 562600), CD11b (562605), CD45R/B220 (562922), TER-119/Erythroid Cells (563998), and Ly-6G and Ly-6C (562709), markers that identified major lineage-committed cell types. BD Via-Probe™ Cell Viability 7-AAD Solution (Cat. No. 555815/555816) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of CD34 (or Ig Isotype control staining) versus the Lineage Cocktail of Markers was derived from gated events with the forward and side light-scatter characteristics of viable (7-AAD negative) bone marrow cells. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Cd34; CD34 antigen; Hematopoietic progenitor cell antigen CD34
Mouse (QC Testing)
Rat IgG2a, κ
Recombinant Mouse CD34
Flow cytometry (Routinely Tested)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cell and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Alexa Fluor® 488 fluorochrome emission is collected at the same instrument settings as for fluorescein isothiocyanate (FITC).
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. This product is provided under an intellectual property license between Life Technologies Corporation and BD Businesses. The purchase of this product conveys to the buyer the non-transferable right to use the purchased amount of the product and components of the product in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The buyer cannot sell or otherwise transfer (a) this product (b) its components or (c) materials made using this product or its components to a third party or otherwise use this product or its components or materials made using this product or its components for Commercial Purposes. Commercial Purposes means any activity by a party for consideration and may include, but is not limited to: (1) use of the product or its components in manufacturing; (2) use of the product or its components to provide a service, information, or data; (3) use of the product or its components for therapeutic, diagnostic or prophylactic purposes; or (4) resale of the product or its components, whether or not such product or its components are resold for use in research. For information on purchasing a license to this product for any other use, contact Life Technologies Corporation, Cell Analysis Business Unit Business Development, 29851 Willow Creek Road, Eugene, OR 97402, USA, Tel: (541) 465-8300. Fax: (541) 335-0504.
  8. Alexa Fluor™ is a trademark of Life Technologies Corporation.
  9. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
567135 Rev. 1
Antibody Details
Down Arrow Up Arrow
RAM34

The RAM34 monoclonal antibody specifically binds to the CD34 glycoprotein on the surface of three independently derived mouse CD34-transfected cell lines. RAM34 antibody also reacts with the mouse cell lines PA6, 416B, Swiss 3T6, NIH, 3T3, DA1, and M1, all of which are positive for expression of mouse CD34 mRNA. Cell lines shown to be negative for CD34 mRNA transcript, including WEHI-3B, EL4, 18.8, and CMT64/61, are also negative for surface expression of CD34 as determined by RAM34 staining. Normal thymocytes and splenocytes are negative for CD34 expression. In the bone marrow, 7-10% of cells are stained with the RAM34 antibody, including most of the Ly-6A/E (Sca-1)+ CD90 (Thy-1)low Lineage Marker- hematopoietic stem cell-enriched subpopulation and myeloerythroid progenitors. CD34 is also expressed on a small percentage of fetal liver cells, including NK-cell progenitors. CD34 has been reported to be expressed on the endothelium of capillaries and, in this form, to function as a ligand for L-selectin. Consistent with this observation, RAM34 antibody stains endothelial cells in spleen, thymus, and postcapillary HEVs in the lymph nodes. It is reported that RAM34 antibody can be used to select CD34+ CD117 (c-Kit)+ Ly-6A/E (Sca-1)+ Lineage Marker- bone marrow-derived hematopoietic stem cells, capable of short-term multi-lineage reconstitution of lethally irradiated mice. In  contrast, the  CD34- CD117+ Sca-1+ Lineage Marker- population contains self-renewing hematopoietic stem cells. Similarly, the bone marrow population with high dye-efflux capacity and highly enriched for long-term reconstituting hematopoietic stem cells, is CD34- CD117 (c-Kit)+ Ly-6A/E (Sca-1)+ Lineage Marker-.

        

567135 Rev. 1
Format Details
Down Arrow Up Arrow
Alexa Fluor™ 488
Alexa Fluor™ 488 Dye is part of the BD blue family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 494-nm and an emission maximum (Em Max) at 517-nm. Alexa Fluor™ 488 is designed to be excited by the Blue laser (488 nm) and detected using an optical filter centered near 520-nm (e.g., a 530/30-nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
Alexa Fluor™ 488
Blue 488 nm
494 nm
517 nm
567135 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (11)

  1. Akashi K, Traver D, Miyamoto T, Weissman IL. A clonogenic common myeloid progenitor that gives rise to all myeloid lineages. Nature. 2000; 404(6774):193-197. (Clone-specific: Flow cytometry). View Reference
  2. Baumheter S, Singer MS, Henzel W, et al. Binding of L-selectin to the vascular sialomucin CD34. Science. 1993; 262(5132):436-438. (Biology). View Reference
  3. Brown J, Greaves MF, Molgaard HV. The gene encoding the stem cell antigen, CD34, is conserved in mouse and expressed in haemopoietic progenitor cell lines, brain, and embryonic fibroblasts. Int Immunol. 1991; 3(2):175-184. (Biology). View Reference
  4. Goodell MA, Rosenzweig M, Kim H, et al. Dye efflux studies suggest that hematopoietic stem cells expressing low or undetectable levels of CD34 antigen exist in multiple species. Nat Med. 1997; 3(12):1337-1345. (Clone-specific: Flow cytometry). View Reference
  5. Lorenz K, Grashoff C, Torka R, et al. Integrin-linked kinase is required for epidermal and hair follicle morphogenesis. J Cell Biol. 2007; 177(3):501-513. (Biology: Immunofluorescence, Immunohistochemistry). View Reference
  6. Lu J, Patrene KD, Herberman RB, Boggs SS. Expression of murine CD34 by fetal liver NK cell progenitors. Exp Hematol. 1999; 27(2):272-281. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
  7. Morel F, Szilvassy SJ, Travis M, Chen B, Galy A. Primitive hematopoietic cells in murine bone marrow express the CD34 antigen. Blood. 1996; 88(10):3774-3784. (Clone-specific: Flow cytometry, Fluorescence activated cell sorting). View Reference
  8. Osawa M, Hanada K, Hamada H, Nakauchi H. Long-term lymphohematopoietic reconstitution by a single CD34-low/negative hematopoietic stem cell. Science. 1996; 273(5272):242-245. (Immunogen: Flow cytometry). View Reference
  9. Spangrude GJ, Heimfeld S, Weissman IL. Purification and characterization of mouse hematopoietic stem cells. Science. 1988; 241(4861):58-62. (Biology). View Reference
  10. Suda J, Sudo T, Ito M, Ohno N, Yamaguchi Y, Suda T. Two types of murine CD34 mRNA generated by alternative splicing. Blood. 1992; 79(9):2288-2295. (Biology). View Reference
  11. Suzuki A, Andrew DP, Gonzalo JA, et al. CD34-deficient mice have reduced eosinophil accumulation after allergen exposure and show a novel crossreactive 90-kD protein. Blood. 1996; 87(9):3550-3562. (Clone-specific: Immunoaffinity chromatography, Immunohistochemistry, Immunoprecipitation). View Reference
View All (11) View Less
567135 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.