CS&T Research Beads (use with BD FACSDiva™ software v7 or later)

BD FACSDiva™ CS&T Research Beads (use with BD FACSDiva™ software v7 or later)

(RUO)
Product Details
Down Arrow Up Arrow


Description

BD FACSDiva™ CS&T research beads (CS&T research beads) are designed for use on BD™ flow cytometers running BD FACSDiva™ software (v7.0 or later). The beads allow the software to automatically characterize, track, and report measurements of supported BD digital flow cytometers. CS&T research beads are dyed with fluorochromes which are excited by the cytometer’s lasers.



Preparation And Storage

Store vials at 2°C to 8°C and protect from light. Do not freeze. The beads are stable until the date shown on the vial label when stored as directed. Do not use after the expiration date. After dilution, the beads are stable for 24 hours at 2°C to 8°C or 8 hours at 15°C to 25°C when protected from light.

655051 Rev. 1
Citations & References
Down Arrow Up Arrow

Development References (9)

  1. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in healthcare settings. MMWR. 1988; 37:377-388. (Biology).
  2. Chase ES, Hoffman RA. Resolution of dimly fluorescent particles: a practical measure of fluorescence sensitivity. Cytometry. 1998; 33:267-279. (Biology).
  3. Clinical and Laboratory Standards Institute. 2005. (Biology).
  4. Establishing optimum baseline PMT gains to maximize resolution on BD Biosciences digital flow cytometers. BD application note: 23-8359-00. 2005. (Biology).
  5. Globally harmonized system of classification and labelling of chemicals (GHS). United Nations Economic Commission for Europe web site. 2009. Available: http://www.phmsa.dot.gov/hazmat/regs/international 2010, September 13.
  6. Hoffman RA. Darzynkiewicz Z, Crissman HA, Robinson JP, ed. Methods in Cell Biology. Elsevier Inc; 2001:300-340.
  7. Hoffman RA. Robinson JP et al, ed. Current Protocols in Cytometry. New York, NY: John Wiley and Sons, Inc; 2005:Unit1-3.
  8. Steen HB. Noise, sensitivity, and resolution of flow cytometers. Cytometry. 1992; 13:822-830. (Biology).
  9. Wood JCS, Hoffman RA. Evaluating fluorescence sensitivity on flow cytometers: an overview. Cytometry. 1998; 33:256-259. (Biology).
View All (9) View Less
655051 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.