BD FACSLyric™ Clinical Flow Cytometry System

Discover how this flow cytometer can transform your clinical lab with outstanding performance, automation and standardization

Discover the BD FACSLyric™ Flow Cytometry System difference

  • Witness clinical performance results you have never seen before through high sensitivity and improved resolution
  • Streamline your lab workflow through flexibility and automation, enabling efficiency and productivity
  • Achieve automated standardization through highly reproducible results and enable collaboration through assay portability
  • See how the BD FACSLyric™ System can transform your lab

 

Get more information from the BD FACSLyric™ Flow Cytometry System Brochure

 
performance1

Features

Discover the BD FACSLyric™ Flow Cytometry System—A Next-Generation Flow Cytometer

Built on a foundation of excellence, experience and expertise, the BD FACSLyric™ Flow Cytometry System is a new standard for cell analysis, transforming the way your lab does flow cytometry. As with all BD instruments, the BD FACSLyric™ Flow Cytometry System is backed by 40 years of BD expert training, service and support—so there’s no limit to your potential.

 

The Power of the BD FACSLyric™ Flow Cytometer

 

  • 4-, 6-, 8-, 10- and 12-color configurations. Onsite upgradeable to adapt to your lab's changing needs
  • Up to 3 lasers—blue, red and violet—12 fluorescence channels and 14 parameters
  • 35,000 events per second maximum acquisition rate; no limit on number of events acquired
  • Automated single-tube QC with BD® CS&T Beads
  • Fluorescence compensation required only every 60 days, improving efficiency and productivity
  • 21 different loading options: plates or tubes; built-in flexibility with BD FACS™ Universal Loader
  • Powered by the BD FACSuite™ Acquisition and Analysis Application, whose password protection, audit trail, electronic signatures and IQ/OQ procedures assist in supporting U.S, FDA 21 CFR Part 11 compliance
  • BD FACSLink™ Laboratory Information System (LIS) Interface and BD Assurity Linc™ Remote Systems Management Software streamline your workflow and help improve productivity through seamless integration
 
Close up of BD FACS™ Universal Loader.
performance1

Performance

A new diagnostic standard delivering outstanding performance and standardization within and between instruments

The BD FACSLyric™ Flow Cytometry System is a high-performance, highly sensitive flow cytometer that demonstrates exceptional resolution and improved separation to make dim and rare cell populations easier to resolve.

 

 

 

Highly reproducible results between instruments drive standardization

 

BD FACSLyric™ System Variance (CVs)
15 BD FACSLyric™ Systems: Lyse/Wash settings and BD FC® Beads
Blue Laser %CV
FITC 4.2
PE 4.4
PE-Cy7 4.8
PerCP 10.2
PerCP-Cy5.5 7.9
Red Laser %CV
APC 5.3
APC-Cy7 4.1
APC-H7 3.9
APC-R700 4.2
   
Violet Laser %CV
BD Horizon™ V450 11.1
BD Horizon™ V500 11
BD Horizon™ BV605 13.6
BD Horizon™ BV711 7.5
BD Horizon™ BV786 15.3

 

Between-instrument reproducibility of target MFI values on the BD FACSLyric™ System

Lyse/wash assay settings were imported across 15 instruments to show effects of standardization on beads. The CVs of the fluorescence intensity across all channels varies by less than 15.3%. Daily QC with one lot of BD® Cytometer Setup & Tracking Beads was run on fifteen BD FACSLyric™ Flow Cytometers. For each instrument, the PMTV gains were automatically adjusted to meet the target values. BD® FC Beads acquired on each BD FACSLyric™ Instrument. The MFI of positive populations was measured for all parameters across all instruments. The %CV is shown. The data for this internal study were acquired using BD® FC Beads across 15 BD FACSLyric™ Instruments. Greater between-instrument variability could be observed when running biological samples, when using non BD reagents or when comparing fewer instruments. 

Applications

A Powerful Solution for CD4 Counts and Other Immunological Assessment

With the BD FACSLyric™ Flow Cytometer, clinical laboratories can obtain repeatable and reliable results for immunological assessment of patients having or suspected of having an immune deficiency such as HIV.

BD FACSLyric™ Clinical Flow Cytometry System

Discover how this flow cytometer can transform your clinical lab with outstanding performance, automation and standardization.

Request Quote
performance1
Journal Publication

Omana-Zapata I, Mutschmann C, Schmitz J, et al. Accurate and reproducible enumeration of T-, B- and NK lymphocytes using the BD FACSLyric 10-Color System: a multisite clinical evaluation. PLoS One. 2019;14(1):e0211207. doi: 10.1371/journal.pone.0211207. 

performance1

Class 1 Laser Product.
The BD FACSLyric™ flow cytometer is for In Vitro Diagnostic Use. CE marked in compliance with the European In Vitro Medical Device Directive 98/79/EC

The BD FACSLyric™ Flow Cytometer is For Research Use Only. Not for use in diagnostic or therapeutic procedures.

The BD FACSLyric™ Flow Cytometer is for In Vitro Diagnostic Use with BD FACSuite™ Clinical Application for up to six colors. The BD FACSLyric™ Flow Cytometer is for Research Use Only with BD FACSuite™ Application for up to 12 colors. Not for use in diagnostic or therapeutic procedures.

Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.