Skip to main content Skip to navigation
Purified Mouse Anti-Human GGA2
Purified Mouse Anti-Human GGA2
Western blot analysis of GGA2 on a EB-1 cell lysate (Human B lymphoblast; Burkitt's lymphoma; ATCC HTB-60). Lane 1: 1:250, lane 2: 1:500, lane 3: 1:1000 dilution of the mouse anti-human GGA2 antibody.
Purified Mouse Anti-Human GGA2
Immunofluorescence staining of human endothelial cells.
Western blot analysis of GGA2 on a EB-1 cell lysate (Human B lymphoblast; Burkitt's lymphoma; ATCC HTB-60). Lane 1: 1:250, lane 2: 1:500, lane 3: 1:1000 dilution of the mouse anti-human GGA2 antibody.
Immunofluorescence staining of human endothelial cells.
Product Details
Down Arrow Up Arrow


BD Transduction Laboratories™
Human (QC Testing)
Mouse IgG1
Human GGA2 aa. 334-445
Western blot (Routinely Tested), Immunofluorescence (Tested During Development)
67 kDa
250 µg/ml
AB_399893
Aqueous buffered solution containing BSA, glycerol, and ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. Store undiluted at -20°C.

Recommended Assay Procedures

Western blot:  Please refer to http://www.bdbiosciences.com/pharmingen/protocols/Western_Blotting.shtml

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
612612 Rev. 1
Antibody Details
Down Arrow Up Arrow
27/GGA2

The ADP-ribosylation factors (ARFs) are a family of small GTPases in the ARF superfamily that include ARFs and ARF-like (ARLs) proteins.  At least six ARFs have been identified in humans: ARF1, ARF2, ARF3, ARF4, ARF5, and ARF6.  ARFs are involved in intravesicular acidification and fusion of microsomal vesicles, endosome fusion, nuclear membrane assembly, and formation of clathrin-coated vesicles.  GGAs are ARF-binding proteins that act as adaptor coat proteins associated with the Golgi complex.  GGA1, GGA2, and GGA3 are homologous proteins that contain N-terminal VHS domains, a GGA and TOM homology region (GAT), and a C-terminal region homologous to the ear domain of γ-adaptins. GGAs co-localize with Golgi markers in the TGN, and GGA3 is found present in coated vesicles and buds associated with the TGN.  The GAT domain of GGA3 facilitates ARF1 binding, Golgi localization, and dissociation from ARF-regulated membranes. The C-terminal region of GGAs bind to MAP1A and rabaptin-5, which are binding partners of γ-adaptins.  Overexpression of GGAs alters the distribution of markers normally found in the TGN.  Thus, GGAs are ARF binding proteins that regulate vesicle dynamics in the TGN.

612612 Rev. 1
Format Details
Down Arrow Up Arrow
Purified
Tissue culture supernatant is purified by either protein A/G or affinity purification methods. Both methods yield antibody in solution that is free of most other soluble proteins, lipids, etc. This format provides pure antibody that is suitable for a number of downstream applications including: secondary labeling for flow cytometry or microscopy, ELISA, Western blot, etc.
Purified
612612 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "612612" on CiteAb

Development References (1)

  1. Hirst J, Lui WW, Bright NA, Totty N, Seaman MN, Robinson MS. A family of proteins with gamma-adaptin and VHS domains that facilitate trafficking between the trans-Golgi network and the vacuole/lysosome. J Cell Biol. 2000; 149(1):67-80. (Biology). View Reference
612612 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.