-
Your selected country is
Luxembourg
- Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Flow cytometric analysis of CD80 (B7-1) expression on Human Raji cells. Cells from the Human Raji (Burkitt's B cell lymphoma, ATCC® CCL-86™) cell line were preincubated with Human BD Fc Block™ (Cat. No. 564219/564220) and stained with either BD Horizon™ BV421 Mouse IgG1, κ Isotype Control (Cat No. 562438, dashed line histogram) or BD OptiBuild™ BV421 Mouse Anti-Human CD80 (B7-1) [Cat No. 751723; solid line histogram] at 1.0 ug/test. DAPI (4',6-Diamidino-2-Phenylindole, Dihydrochloride) Solution (Cat. No. 564907) was added to cells right before analysis. The fluorescence histogram showing CD80 (B7-1) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of viable (DAPI-negative) Raji cells. Flow cytometry and data analysis were performed using a BD FACSCelesta™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
BD OptiBuild™ BV421 Mouse Anti-Human CD80 (B7-1)
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.
For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime BD Horizon Brilliant dyes are used in a multicolor flow cytometry panel. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).
Product Notices
- The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
- Researchers should determine the optimal concentration of this reagent for their individual applications.
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- BD Horizon Brilliant Violet 421 is covered by one or more of the following US patents: 8,158,444; 8,362,193; 8,575,303; 8,354,239.
- BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
Companion Products
The 2D10.4 monoclonal antibody, also known as 2D10, specifically recognizes CD80 which is otherwise known as Activation B7-1 antigen (B7-1), B7.1, or B7. This ~60 kDa single-pass type I transmembrane glycoprotein is encoded by CD80 (CD80 molecule) that belongs to the immunoglobulin gene superfamily (IgSF). CD80 (B7-1) is comprised of an extracellular region with an IgV-like domain followed by an IgC-like domain, a transmembrane region and a cytoplasmic tail. It is variably expressed on activated B cells, activated CD4+ and CD8+ T cells, macrophages, and dendritic cells. CD80 (B7-1) serves as a ligand for the CD28 and CD152 (CTLA-4) coreceptors that are differentially expressed on T cells. CD80 (B7-1) engagement of CD28 costimulates T cells activated through their TCR-CD3 complex whereas its interaction with CD152 (CTLA-4) generates an inhibitory signal for T cell responses.
Development References (6)
-
Battifora M, Pesce G, Paolieri F, et al. B7.1 costimulatory molecule is expressed on thyroid follicular cells in Hashimoto's thyroiditis, but not in Graves' disease.. J Clin Endocrinol Metab. 1998; 83(11):4130-9. (Clone-specific: Flow cytometry, Functional assay, Immunocytochemistry, Immunohistochemistry). View Reference
-
Jones M, Mason DY. CD80 Workshop Panel report. In: Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997:186-187.
-
Mielle J, Audo R, Hahne M, et al. IL-10 Producing B Cells Ability to Induce Regulatory T Cells Is Maintained in Rheumatoid Arthritis.. Front Immunol. 2018; 9:961. (Clone-specific: Flow cytometry). View Reference
-
Orbach A, Rachmilewitz J, Shani N, et al. CD40·FasL and CTLA-4·FasL fusion proteins induce apoptosis in malignant cell lines by dual signaling.. Am J Pathol. 2010; 177(6):3159-68. (Clone-specific: Flow cytometry). View Reference
-
Werz O, Gerstmeier J, Libreros S, et al. Human macrophages differentially produce specific resolvin or leukotriene signals that depend on bacterial pathogenicity.. Nat Commun. 2018; 9(1):59. (Clone-specific: Flow cytometry). View Reference
-
van der Merwe PA, Bodian DL, Daenke S, Linsley P, Davis SJ. CD80 (B7-1) binds both CD28 and CTLA-4 with a low affinity and very fast kinetics.. J Exp Med. 1997; 185(3):393-403. (Clone-specific: Western blot). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.