-
Your selected country is
Luxembourg
- Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Discover the BD FACSLyric™ Flow Cytometry System difference.
- Witness clinical performance results you have never seen before through high sensitivity and improved resolution
- Streamline your lab workflow through flexibility and automation, enabling efficiency and productivity
- Achieve automated process driving highly reproducible results and enable collaboration through assay portability
- See how the BD FACSLyric™ System can transform your lab.
Features
Discover the BD FACSLyric™ Flow Cytometry System—A Next-Generation Flow Cytometer
Built on a foundation of excellence, experience and expertise, the BD FACSLyric™ Flow Cytometry System is a new standard for cell analysis, transforming the way your lab does flow cytometry. As with all BD instruments, the BD FACSLyric™ Flow Cytometry System is backed by 40 years of BD expert training, service and support—so there’s no limit to your potential.
The Power of the BD FACSLyric™ Flow Cytometer
- 4-, 6-, 8-, 10- and 12-color configurations. Onsite upgradeable to adapt to your lab's changing needs
- Up to 3 lasers—blue, red and violet—12 fluorescence channels and 14 parameters
- 35,000 events per second maximum acquisition rate; no limit on number of events acquired
- Automated single-tube QC with BD™ CS&T Beads
- Fluorescence compensation required only every 60 days, improving efficiency and productivity
- 21 different loading options: plates or tubes; built-in flexibility with BD FACS™ Universal Loader
- Powered by the BD FACSuite™ Software for acquisition and analysis, supporting many functions and options relevant to U.S. FDA 21 CFR Part 11 offering password protection, audit trail, electronic signatures and IQ/OQ procedures
- BD FACSLink™ Laboratory Information System (LIS) Interface and BD Assurity Linc™ Remote Systems Management Software streamline your workflow and help improve productivity through seamless integration.
Get more information from the BD FACSLyric™ Flow Cytometry System Brochure.
See how you can simplify your workflow using the automated instrument setup and compensation on the BD FACSLyric™ System.
Performance
A new diagnostic tool delivering outstanding performance and standardization.
The BD FACSLyric™ Flow Cytometry System is a high-performance, highly sensitive flow cytometer that demonstrates exceptional resolution and improved separation to make dim and rare cell populations easier to resolve.
Higher sensitivity makes dim and rare populations easier to resolve.
Improvement in stain index of 8–190% across all parameters ensures better separation and enables faster analysis and easier gating.
Assay portability simplifies and standardizes instrument setup within your lab and between labs. It also enables the sharing and exchange of data, ideas and user-defined protocols within and between institutions.
Highly reproducible results between instruments drive standardization
Blue Laser | %CV |
FITC | 4.2 |
PE | 4.4 |
PE-Cy7 | 4.8 |
PerCP | 10.2 |
PerCP-Cy5.5 | 7.9 |
Red Laser | %CV |
APC | 5.3 |
APC-Cy7 | 4.1 |
APC-H7 | 3.9 |
APC-R700 | 4.2 |
Violet Laser | %CV |
BD Horizon™ V450 | 11.1 |
BD Horizon™ V500 | 11 |
BD Horizon™ BV605 | 13.6 |
BD Horizon™ BV711 | 7.5 |
BD Horizon™ BV786 | 15.3 |
Between-instrument reproducibility of target MFI values on the BD FACSLyric™ System
Lyse/wash assay settings were imported across 15 instruments to show effects of standardization on beads. The CVs of the fluorescence intensity across all channels varies by less than 15.3%. Daily QC with one lot of BD® Cytometer Setup & Tracking Beads was run on fifteen BD FACSLyric™ Flow Cytometers. For each instrument, the PMTV gains were automatically adjusted to meet the target values. BD® FC Beads acquired on each BD FACSLyric™ Instrument. The MFI of positive populations was measured for all parameters across all instruments. The %CV is shown. The data for this internal study were acquired using BD® FC Beads across 15 BD FACSLyric™ Instruments. Greater between-instrument variability could be observed when running biological samples, when using non BD reagents or when comparing fewer instruments.
Applications
A Powerful Solution for CD4 Counts and Other Immunological Assessment
With the BD FACSLyric™ Flow Cytometer, clinical laboratories can obtain repeatable and reliable results for immunological assessment of patients having or suspected of having an immune deficiency such as HIV.
BD Multitest™ Reagents for 3, 4 and 6-color TBNK analysis, formulated to be used with BD Trucount™ Tubes, provide absolute counting capability.
The BD FACSuite™ Clinical Application, with predefined templates for 4- and 6-color T, B and/or NK cell analysis, provides reproducible and consistent results.
Each reagent includes a cocktail of multiple fluorescently labeled monoclonal antibodies, premixed at the appropriate titer to ensure quality staining.
A streamlined methodology for immunological assessment of patients having or suspected of having an immune deficiency such as HIV using the BD FACSLyric™ Flow Cytometer.
Find out more from the BD FACSLyric™ Flow Cytometer product information sheet.
"BD is positioned with BD™ CS&T and BD™ FC Bead technology to enable instrument standardization simply from day to day, instrument to instrument, and lab to lab."
"BD is positioned with BD™ CS&T and BD™ FC Bead technology to enable instrument standardization simply from day to day, instrument to instrument, and lab to lab."
“The consistency and the regulatory compliance of FACSLyric [Flow Cytometer]’s output is what really drew us to the platform. It is currently unmatched by other flow cytometers in its ability to generate reliable, repeatable results across tests and instruments—even for the most complex assays we deal with day to day. We’ve found it particularly beneficial for multiparameter testing for CAR T cells and immunophenotyping.”
“The consistency and the regulatory compliance of FACSLyric [Flow Cytometer]’s output is what really drew us to the platform. It is currently unmatched by other flow cytometers in its ability to generate reliable, repeatable results across tests and instruments—even for the most complex assays we deal with day to day. We’ve found it particularly beneficial for multiparameter testing for CAR T cells and immunophenotyping.”
“The assay portability of BD FACSLyric is the key to efficient method transfer and high data reproducibility. It represents a clear advantage in a regulated environment, where conditions must be met to produce valid results of a guaranteed level of quality. Functional immune cell–based assays and cytokine quantification in preclinical and clinical drug development is a particularly important area where BD FACSLyric offers clear technical advantages.”
“The assay portability of BD FACSLyric is the key to efficient method transfer and high data reproducibility. It represents a clear advantage in a regulated environment, where conditions must be met to produce valid results of a guaranteed level of quality. Functional immune cell–based assays and cytokine quantification in preclinical and clinical drug development is a particularly important area where BD FACSLyric offers clear technical advantages.”
- Instructions for Use
- Brochure
- Filter Guide
- Technical Specifications
- Product List
- Product Information Sheets
- Application Note
- Posters
- 2016 ESCCA: Simplified Workflow using Automated Setup and Compensation
- 2016 ESCCA: Performance Evaluation of 10-color system with Tritest Reagents
- 2017 CYTO: Long term CST set-up stability
- 2017 ESCCA: Assay Portability for T, B, NK Populations
- 2019 ICCS: Development of a Dried-down, Multicolor Reagent Solution for Enhanced Flow-cytometric Applications
Request a Quote
Please fill in the following information and we will get in touch with you regarding your query.
Omana-Zapata I, Mutschmann C, Schmitz J, et al. Accurate and reproducible enumeration of T-, B- and NK lymphocytes using the BD FACSLyric 10-Color System: a multisite clinical evaluation. PLoS One. 2019;14(1):e0211207. doi: 10.1371/journal.pone.0211207.
Interested in preparing for the IVDR? Visit our IVDR page to learn more about the measures you can take to prepare your lab.
BD FACSCanto™ II Flow Cytometer, BD Multitest™ Reagents for 3, 4 and 6-color TBNK analysis, formulated to be used with BD Trucount™ Tubes as specified on this page and BD FACSLyric™ Flow Cytometer with the BD FACSuite™ Clinical and BD FACSuite™ applications are in vitro diagnostic medical devices bearing a CE mark.
BD Flow Cytometers are Class 1 Laser Products.
Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.