RY743 Rat Anti-Human IL-2
RY743 Rat Anti-Human IL-2
Two-color flow cytometric analysis of IL-2 in stimulated Human peripheral blood mononuclear cells.  Human peripheral blood mononuclear cells (PBMC) were stimulated for 5 hours with Phorbol 12-Myristate 13-Acetate (Sigma P-8139; 50 ng/ml final concentration) and Ionomycin (Sigma I-0634; 1 μg/ml final concentration) in the presence of BD GolgiStop™ Protein Transport Inhibitor (containing Monensin) [Cat. No. 554724]. The cells were harvested, washed with BD Pharmingen™ Stain Buffer (FBS) [Cat. No. 554656], and fixed and permeabilized with BD Cytofix/Cytoperm™ Fixation and Permeabilization Solution (Cat. No. 554722). The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with BD Horizon™ BUV395 Mouse Anti-Human CD3 antibody (Cat. No. 563546) and with either BD Horizon™ RY743 Rat IgG2a, κ Isotype Control (Cat. No. 572210; Left Plot) or BD Horizon™ RY743 Rat Anti-Human IL-2 antibody (Cat. No. 572235/572236; Right Plot). The bivariate pseudocolor density plot showing the correlated expression of IL-2 (or Ig Isotype control staining) versus CD3 was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Samples were acquired using a BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.10 Software
Two-color flow cytometric analysis of IL-2 in stimulated Human peripheral blood mononuclear cells.  Human peripheral blood mononuclear cells (PBMC) were stimulated for 5 hours with Phorbol 12-Myristate 13-Acetate (Sigma P-8139; 50 ng/ml final concentration) and Ionomycin (Sigma I-0634; 1 μg/ml final concentration) in the presence of BD GolgiStop™ Protein Transport Inhibitor (containing Monensin) [Cat. No. 554724]. The cells were harvested, washed with BD Pharmingen™ Stain Buffer (FBS) [Cat. No. 554656], and fixed and permeabilized with BD Cytofix/Cytoperm™ Fixation and Permeabilization Solution (Cat. No. 554722). The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with BD Horizon™ BUV395 Mouse Anti-Human CD3 antibody (Cat. No. 563546) and with either BD Horizon™ RY743 Rat IgG2a, κ Isotype Control (Cat. No. 572210; Left Plot) or BD Horizon™ RY743 Rat Anti-Human IL-2 antibody (Cat. No. 572235/572236; Right Plot). The bivariate pseudocolor density plot showing the correlated expression of IL-2 (or Ig Isotype control staining) versus CD3 was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Samples were acquired using a BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.10 Software
商品详情
Down Arrow Up Arrow


BD Horizon™
IL2; Interleukin-2; T-cell growth factor; TCGF
Human (QC Testing), Rhesus,Cynomolgus,Baboon (Tested in Development)
Rat IgG2a, κ
Human IL-2 Recombinant Protein
Intracellular staining (flow cytometry) (Routinely Tested)
5 µl/test
3558
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

商品通知

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  7. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  8. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
  9. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  10. For U.S. patents that may apply, see bd.com/patents.
  11. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  12. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  13. Tandem fluorochromes contain both an energy donor and an energy acceptor. Although every effort is made to minimize the lot-to-lot variation in the efficiency of the fluorochrome energy transfer, differences in the residual emission from the donor may be observed. Additionally, multi-laser cytometers may directly excite both the donor and acceptor fluorochromes. Therefore, we recommend for every tandem conjugate, a matched individual single-stain control be acquired for generating a compensation or spectral unmixing matrix.
572235 Rev. 1
抗体详情
Down Arrow Up Arrow
MQ1-17H12

The MQ1-17H12 monoclonal antibody specifically binds to the multifunctional cytokine, human Interleukin-2 (IL-2). IL-2 is produced by activated T cells and has multiple functions that can affect the growth, proliferation, differentiation and survival of many different target cell types including T cells, B cells, NK cells, monocytes and macrophages. The immunogen used to generate the MQ1-17H12 hybridoma was purified recombinant human IL-2 protein. The MQ1-17H12 antibody reportedly neutralizes the biological activity of human IL-2.

572235 Rev. 1
格式详情
Down Arrow Up Arrow
RY743
The BD Horizon RealYellow™ 743 (RY743) Dye is part of the BD® family of yellow-green dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 557 nm and an emission maximum (Em Max) at 743 nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RY743 is optimized for detection on spectral cytometers and designed to be excited by the Yellow-Green laser (561 nm) with minimal excitation by the Blue laser (488 nm). Given its unique emission max, RY743 can be used on a spectral instrument in combination with RY703 and either RY775 or PE-Cy7 to provide an additional color excited by the Yellow-Green laser. For conventional instruments equipped with a Yellow-Green laser, we recommend using an optical filter centered near 750 nm (e.g., a 750/60-nm bandpass filter). Please ensure that your instrument configuration (lasers and optical filters) is appropriate for this dye.
RY743
Yellow-Green 561 nm
557 nm
743 nm
572235 Rev.1
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "572235" on CiteAb

研发参考 (10)

  1. Abrams J. Immunoenzymetric assay of mouse and human cytokines using NIP-labeled anti-cytokine antibodies. Curr Protoc Immunol. 2001; 1:6.20-6.21. (Clone-specific: ELISA). 查看参考
  2. Abrams JS, Roncarolo MG, Yssel H, Andersson U, Gleich GJ, Silver JE. Strategies of anti-cytokine monoclonal antibody development: immunoassay of IL-10 and IL-5 in clinical samples. Immunol Rev. 1992; 127:5-24. (Clone-specific: Blocking, ELISA, Immunoprecipitation). 查看参考
  3. Cardone J, Le Friec G, Vantourout P, et al. Complement regulator CD46 temporally regulates cytokine production by conventional and unconventional T cells.. Nat Immunol. 2010; 11(9):862-71. (Clone-specific: Functional assay, Neutralization). 查看参考
  4. Foulds KE, Donaldson M, Roederer M. OMIP-005: Quality and phenotype of antigen-responsive rhesus macaque T cells.. Cytometry A. 2012; 81(5):360-1. (Clone-specific: Flow cytometry). 查看参考
  5. Geisbert TW, Bailey M, Geisbert JB, et al. Vector choice determines immunogenicity and potency of genetic vaccines against Angola Marburg virus in nonhuman primates.. J Virol. 2010; 84(19):10386-94. (Clone-specific: Flow cytometry). 查看参考
  6. Jason J, Larned J. Single-cell cytokine profiles in normal humans: comparison of flow cytometric reagents and stimulation protocols. J Immunol Methods. 1997; 207(1):13-22. (Clone-specific: Flow cytometry). 查看参考
  7. Mascher B, Schlenke P, Seyfarth M. Expression and kinetics of cytokines determined by intracellular staining using flow cytometry. J Immunol Methods. 1999; 223(1):115-121. (Clone-specific: Flow cytometry). 查看参考
  8. Moris P, Bellanger A, Ofori-Anyinam O, Jongert E, Yarzabal Rodriguez JP, Janssens M. Whole blood can be used as an alternative to isolated peripheral blood mononuclear cells to measure in vitro specific T-cell responses in human samples.. J Immunol Methods. 2021; 492:112940. (Clone-specific: Flow cytometry). 查看参考
  9. Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Methodology: Flow cytometry). 查看参考
  10. Qiu X, Audet J, Wong G, et al. Successful treatment of ebola virus-infected cynomolgus macaques with monoclonal antibodies.. Sci Transl Med. 2012; 4(138):138ra81. (Clone-specific: Flow cytometry). 查看参考
查看所有文件 (10) 查看更少内容
572235 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.