RY703 Rat Anti-Mouse CD21/CD35
商品详情
Down Arrow Up Arrow


BD OptiBuild™
CD21/CD35; CR2/CR1; mCR1/mCR2
Mouse (Tested in Development)
Rat SD, also known as Sprague-Dawley (outbred) IgG2a, κ
Purified Mouse CR1 Protein
Flow cytometry (Qualified)
0.2 mg/ml
12902
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

商品通知

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  8. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  9. An isotype control should be used at the same concentration as the antibody of interest.
  10. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
  11. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  12. Tandem fluorochromes contain both an energy donor and an energy acceptor. Although every effort is made to minimize the lot-to-lot variation in the efficiency of the fluorochrome energy transfer, differences in the residual emission from the donor may be observed. Additionally, multi-laser cytometers may directly excite both the donor and acceptor fluorochromes. Therefore, we recommend for every tandem conjugate, a matched individual single-stain control be acquired for generating a compensation or spectral unmixing matrix.
770863 Rev. 1
抗体详情
Down Arrow Up Arrow
7E9

The 7E9 antibody specifically recognizes CD21/CD35, an epitope shared by mouse Complement receptor 2 (CR2) and Complement receptor 1 (CR1), which are also known as CD21 and CD35, respectively. Mouse CD21 and CD35 are ~145-kDa and ~190-kDa single pass type I transmembrane glycoproteins, respectively. Unlike human CD21 and CD35 that are encoded by separate CR2 and CR1 genes, mouse CD21 and CD35 are encoded by a single Cr2 gene and are generated by alternative mRNA splicing. CD21 and CD35 are expressed on B cells and follicular dendritic cells (FCD) but not on thymocytes, T cells, erythrocytes, or platelets. CD35 is also expressed on macrophages and activated granulocytes. CD21 binds to cleaved C3b fragments, including C3d- and C3dg-bound to antigen, whereas CD35 binds to C3b-, iC3b-, and C4b-bound complexes. These receptors play many important roles including the transport, presentation, and retention of complement fragment-tagged antigens and immune complexes crucial for generating strong B cell antibody-producing responses. Complement-tagged antigen can bind to CD21, part of the B cell coreceptor complex and to the B cell receptor for antigen (BCR) which facilitates the antigen-driven activation of B cell responses. CD35 interacts with other regulatory factors to promote C3b and C4b degradation as well as playing roles in stimulating phagocytic functions in activated leucocytes. The 7E9 antibody recognizes an epitope on CD35 distinct from the epitope recognized by the mouse CD35-specific clone, 8C12, as well as the mouse CD21/CD35-specific clone, 7G6.

770863 Rev. 1
格式详情
Down Arrow Up Arrow
RY703
The BD Horizon RealYellow™ 703 (RY703) Dye is part of the BD® family of yellow-green dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 557-nm and an emission maximum (Em Max) at 703-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RY703 can be used on both spectral and conventional cytometers and is designed to be excited by the Yellow-Green laser (561-nm) with minimal excitation by the 488-nm Blue laser. For conventional instruments equipped with a Yellow-Green laser (561-nm), RY703 can be used as an alternative to PE-Cy5.5 and we recommend using an optical filter centered near 700-nm (eg, a 695/40-nm bandpass filter).
altImg
RY703
Yellow-Green 561 nm
557 nm
703 nm
770863 Rev.1
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "770863" on CiteAb

研发参考 (6)

  1. Ahearn JM, Fischer MB, Croix D, et al. Disruption of the Cr2 locus results in a reduction in B-1a cells and in an impaired B cell response to T-dependent antigen. Immunity. 1996; 4(3):251-262. (Clone-specific: Flow cytometry). 查看参考
  2. Heyman B, Wiersma EJ, Kinoshita T. In vivo inhibition of the antibody response by a complement receptor-specific monoclonal antibody. J Exp Med. 1990; 172(2):665-668. (Clone-specific: In vivo exacerbation). 查看参考
  3. Jacobson AC, Weis JH. Comparative functional evolution of human and mouse CR1 and CR2.. J Immunol. 2008; 181(5):2953-9. (Biology). 查看参考
  4. Kinoshita T, Takeda J, Hong K, Kozono H, Sakai H, Inoue K. Monoclonal antibodies to mouse complement receptor type 1 (CR1). Their use in a distribution study showing that mouse erythrocytes and platelets are CR1-negative. J Immunol. 1988; 140(9):3066-3072. (Immunogen: Flow cytometry, Immunoprecipitation, Radioimmunoassay). 查看参考
  5. Kinoshita T, Thyphronitis G, Tsokos GC, et al. Characterization of murine complement receptor type 2 and its immunological cross-reactivity with type 1 receptor. Int Immunol. 1990; 2(7):651-659. (Clone-specific: Flow cytometry). 查看参考
  6. Molina H, Holers VM, Li B, et al. Markedly impaired humoral immune response in mice deficient in complement receptors 1 and 2. Proc Natl Acad Sci U S A. 1996; 93(8):3357-3361. (Clone-specific: Flow cytometry). 查看参考
查看所有文件 (6) 查看更少内容
770863 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.