Skip to main content Skip to navigation
RY703 Biosimilar Anti-Human CD20

BD OptiBuild™ RY703 Biosimilar Anti-Human CD20

克隆 Obinutuzumab297.rMAb (also known as Obinutuzumab N297A Biosimilar.rMAb)

(RUO)
商品详情
Down Arrow Up Arrow


BD OptiBuild™
B1; Bp35; LEU-16; MS4A1
Human (Tested in Development)
Human IgG1, κ
Human CD20
Flow cytometry (Qualified)
0.2 mg/ml
931
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

商品通知

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  8. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  9. An isotype control should be used at the same concentration as the antibody of interest.
  10. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
  11. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  12. Tandem fluorochromes contain both an energy donor and an energy acceptor. Although every effort is made to minimize the lot-to-lot variation in the efficiency of the fluorochrome energy transfer, differences in the residual emission from the donor may be observed. Additionally, multi-laser cytometers may directly excite both the donor and acceptor fluorochromes. Therefore, we recommend for every tandem conjugate, a matched individual single-stain control be acquired for generating a compensation or spectral unmixing matrix.
  13. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
770762 Rev. 1
抗体详情
Down Arrow Up Arrow
Obinutuzumab297.rMAb

The Obinutuzumab297.rMAb (also known as, Obinutuzumab N297A Biosimilar.rMAb) is a research grade humanized recombinant human IgG1, kappa antibody that specifically recognizes the extracellular domain of human CD20 similarly to the therapeutic Obinutuzumab antibody. The Obinutuzumab297.rMAb uses the same variable region sequences as Obinutuzumab, combined with constant region sequences derived from consensus sequences of human IgG1, kappa. The asparagine at position 297 of the constant heavy chain has been replaced with alanine (N297A) to further reduce Fc receptor interactions of this reagent. Obinutuzumab triggers target cell death through multiple mechanisms including complement-dependent cytotoxicity (CDC), antibody-dependent cellular cytotoxicity (ADCC), and apoptosis. The therapeutic Obinutuzumab has been approved to treat human B cell malignancies, autoimmune disorders, and transplant rejection. CD20 is a 33-37 kDa, unglycosylated four-transmembrane phosphoprotein with a cytoplasmic N-terminus and C-terminus that is encoded by MS4A1 (Membrane-spanning 4-domains, subfamily A, member 1). CD20 is expressed on pre-B-cells, naive and activated B cells, memory B cells, and at lower levels on a small subset of T cells but is absent from plasmablasts and plasma cells. It is also expressed on most malignant B cells and CD20-positive T-cell lymphomas. CD20 functions in mediating calcium transport and B cell activation, differentiation, and survival.

   The Obinutuzumab297.rMAb is intended for research use only. It is not intended for use in therapeutic or diagnostic procedures for humans or animals.

770762 Rev. 1
格式详情
Down Arrow Up Arrow
RY703
The BD Horizon RealYellow™ 703 (RY703) Dye is part of the BD® family of yellow-green dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 557-nm and an emission maximum (Em Max) at 703-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RY703 can be used on both spectral and conventional cytometers and is designed to be excited by the Yellow-Green laser (561-nm) with minimal excitation by the 488-nm Blue laser. For conventional instruments equipped with a Yellow-Green laser (561-nm), RY703 can be used as an alternative to PE-Cy5.5 and we recommend using an optical filter centered near 700-nm (eg, a 695/40-nm bandpass filter).
altImg
RY703
Yellow-Green 561 nm
557 nm
703 nm
770762 Rev.1
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "770762" on CiteAb

研发参考 (5)

  1. Almasri NM, Duque RE, Iturraspe J, Everett E, Braylan RC. Reduced expression of CD20 antigen as a characteristic marker for chronic lymphocytic leukemia. Am J Hematol. 1992; 40:259-263. (Biology).
  2. Brekke OH, Sandlie I. Therapeutic antibodies for human diseases at the dawn of the twenty-first century.. Nat Rev Drug Discov. 2003; 2(1):52-62. (Biology). 查看参考
  3. Hultin LE, Hausner MA, Hultin PM, Giorgi JV. CD20 (pan-B cell) antigen is expressed at a low level on asubpopulation of human T lymphocytes. Cytometry. 1993; 14:196-204. (Biology).
  4. Tobinai K, Klein C, Oya N, Fingerle-Rowson G. A Review of Obinutuzumab (GA101), a Novel Type II Anti-CD20 Monoclonal Antibody, for the Treatment of Patients with B-Cell Malignancies.. Adv Ther. 2017; 34(2):324-356. (Biology). 查看参考
  5. Zola H, Swart B, Nicholson I, Voss E. CD20. In: Zola H. Leukocyte and stromal cell molecules : the CD markers. Hoboken, N.J.: Wiley-Liss; 2007:72.
查看所有文件 (5) 查看更少内容
770762 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.