
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
BD Horizon™ RY610 Mouse Anti-Human Granzyme B
克隆 GB11 (RUO)

Two-color flow cytometric analysis of Granzyme B expression in Human peripheral blood lymphocytes. Human whole blood was treated with BD Phosflow™ Lyse/Fix Buffer (Cat. No. 558049) to lyse erythrocytes and fix leukocytes. The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with APC Mouse Anti-Human CD8 antibody (Cat. No. 561953) and with either BD Horizon™ RY610 Mouse IgG1, κ Isotype Control (Cat. No. 571151; Left Plot) or BD Horizon™ RY610 Mouse Anti-Human Granzyme B antibody (Cat. No. 571160/571161; Right Plot). The bivariate pseudocolor density plot showing the correlated expression of Granzyme B (or Ig Isotype control staining) versus CD8 was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD FACSymphony™ A5 SE Cell Analyzer System and FlowJo™ Software.


Two-color flow cytometric analysis of Granzyme B expression in Human peripheral blood lymphocytes. Human whole blood was treated with BD Phosflow™ Lyse/Fix Buffer (Cat. No. 558049) to lyse erythrocytes and fix leukocytes. The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with APC Mouse Anti-Human CD8 antibody (Cat. No. 561953) and with either BD Horizon™ RY610 Mouse IgG1, κ Isotype Control (Cat. No. 571151; Left Plot) or BD Horizon™ RY610 Mouse Anti-Human Granzyme B antibody (Cat. No. 571160/571161; Right Plot). The bivariate pseudocolor density plot showing the correlated expression of Granzyme B (or Ig Isotype control staining) versus CD8 was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD FACSymphony™ A5 SE Cell Analyzer System and FlowJo™ Software.

Two-color flow cytometric analysis of Granzyme B expression in Human peripheral blood lymphocytes. Human whole blood was treated with BD Phosflow™ Lyse/Fix Buffer (Cat. No. 558049) to lyse erythrocytes and fix leukocytes. The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with APC Mouse Anti-Human CD8 antibody (Cat. No. 561953) and with either BD Horizon™ RY610 Mouse IgG1, κ Isotype Control (Cat. No. 571151; Left Plot) or BD Horizon™ RY610 Mouse Anti-Human Granzyme B antibody (Cat. No. 571160/571161; Right Plot). The bivariate pseudocolor density plot showing the correlated expression of Granzyme B (or Ig Isotype control staining) versus CD8 was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD FACSymphony™ A5 SE Cell Analyzer System and FlowJo™ Software.


BD Horizon™ RY610 Mouse Anti-Human Granzyme B

监管状态图例
未经BD明确书面授权,严禁使用未经许可的任何商品。
准备和存储
推荐的实验流程
BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.
商品通知
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
- An isotype control should be used at the same concentration as the antibody of interest.
- Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
- Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- CF™ is a trademark of Biotium, Inc.
- For U.S. patents that may apply, see bd.com/patents.
配套商品





The GB11 antibody specifically reacts with human granzyme B, a serine protease of approximately 32 kDa. Granzyme B is stored in the granules of cytotoxic T lymphocytes and NK cells along with the pore-forming protein perforin. In the classic model of target cell lysis, perforins create holes in the target cell membrane allowing entrance of granzymes. Granzyme B has been shown to act on specific substrates including caspase-3, -7, -9, and -10 which in turn give rise to enzymes that mediate apoptosis. Granzyme B may also be involved in the hydrolysis of extracellular matrix components. Detectable levels of granzyme B have been detected in sera from healthy volunteers. The immunogen used to generate the GB11 hybridoma was human granzyme B isolated from an NK cell line.

研发参考 (8)
-
Hamann D, Baars PA, Rep MH. Phenotypic and functional separation of memory and effector human CD8+ T cells. J Exp Med. 1997; 186(9):1407-1418. (Clone-specific: Intracellular Staining/Flow Cytometry). 查看参考
-
Poe M, Blake JT, Boulton DA. Human cytotoxic lymphocyte granzyme B. Its purification from granules and the characterization of substrate and inhibitor specificity. J Biol Chem. 1991; 266(1):98-103. (Biology). 查看参考
-
Ronday HK, van der Laan WH, Tak PP et al. Human granzyme B mediates cartilage proteoglycan degradation and is expressed at the invasive front of the synovium in rheumatoid arthritis. Rheumatology (Oxford). 2001; 40:55-61. (Biology). 查看参考
-
Smyth MJ, Kelly JM, Sutton VR et al. Unlocking the secrets of cytotoxic granule proteins. J Leukoc Biol. 2001; 70:18-29. (Biology). 查看参考
-
Spaeny-Dekking EH, Hanna WL, Wolbink AM et al. Extracellular granzymes A and B in humans: detection of native species during CTL responses in vitro and in vivo. J Immunol. 1998; 160:3610. (Immunogen: ELISA, Radioimmunoassay). 查看参考
-
Trapani JA, Klein JL, White PC, and Dupont B. Molecular cloning of an inducible serine esterase gene from human cytotoxic lymphocytes. Proc Natl Acad Sci U S A. 1988; 5:6924-6928. (Biology). 查看参考
-
Trapani JA, Smyth MJ, Apostolidis VA, Dawson M, and Browne KA. Granule serine proteases are normal nuclear constituents of natural killer cells. J Biol Chem. 1994; 269:18359-18365. (Biology). 查看参考
-
Wever PC, Van Der Vliet HJ, Spaeny LH . The CD8+ granzyme B+ T-cell subset in peripheral blood from healthy individuals contains activated and apoptosis-prone cells. Immunology. 1998; 93(3):383-389. (Immunogen: ELISA, Flow cytometry, Immunoprecipitation, Intracellular Staining/Flow Cytometry, Radioimmunoassay). 查看参考
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.