RB780 Mouse Anti-Human Active β2 Integrin (CD18)

BD OptiBuild™ RB780 Mouse Anti-Human Active β2 Integrin (CD18)

克隆 mAb 24 (also known as 24; m24; M24; mAb24)

(RUO)
商品详情
Down Arrow Up Arrow


BD OptiBuild™
ITGB2; Integrin beta-2; Integrin β2; LFA-1 β; LFA1b; beta 2 integrin; β2 integrin
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Fibronectin-purified Human Monocytes
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

商品通知

  1. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  5. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  6. An isotype control should be used at the same concentration as the antibody of interest.
  7. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  11. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
  12. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
755487 Rev. 1
抗体详情
Down Arrow Up Arrow
mAb 24

mAb 24 (also known as 24 or m24) specifically recognizes a divalent cation-dependent epitope expressed by active human Integrin β2 which is also known as CD18. Integrin β2 is an ~95 kDa type I transmembrane glycoprotein that is encoded by ITGB2 (integrin subunit beta 2). Integrin β2 (CD18) noncovalently associates with other integrin α chains to form αLβ2 (CD11a/CD18; also known as, LFA-1), αMβ2 (CD11b/CD18; Mac-1, CR3), αXβ2 (CD11c/CD18; p150,95; CR4) and αDβ2 (CD11d/CD18) heterodimers. These integrins are variably expressed on lymphocytes, NK cells, neutrophils, eosinophils, basophils, monocytes, macrophages, Langerhans cells, and dendritic cells (DCs). These leucocyte integrins bind to various ligands and mediate cellular adhesion and signaling responses that regulate cellular activation, effector function, and migration. mAb 24 binds to the extended/open, high-affinity ligand-binding conformation of active Integrin β2 (CD18). mAb 24 can be used as a reporter antibody for the activated status of Integrin β2-containing receptors expressed by leucocytes in response to various stimuli in the presence of Mg2+ or Mn2+.

755487 Rev. 1
格式详情
Down Arrow Up Arrow
RB780
The BD Horizon RealBlue™ 780 (RB780) Dye is part of the BD family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 781-nm. Driven by BD innovation, RB780 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), RB780 can be used as an alternative to PE-Cy7 and we recommend using an optical filter centered near 780-nm (eg, a 780/60-nm bandpass filter). For spectral instruments equipped with a Blue laser (488-nm), it can be used in conjunction with PE-Cy7. RB780 is on average brighter than PE-Cy7 and has minimal spillover into Yellow-Green detectors.
altImg
RB780
Blue 488 nm
498 nm
781 nm
755487 Rev.1
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "755487" on CiteAb

研发参考 (7)

  1. Chen X, Xie C, Nishida N, Li Z, Walz T, Springer TA. Requirement of open headpiece conformation for activation of leukocyte integrin alphaXbeta2.. Proc Natl Acad Sci U S A. 2010; 107(33):14727-32. (Clone-specific). 查看参考
  2. Dransfield I, Cabañas C, Craig A, Hogg N. Divalent cation regulation of the function of the leukocyte integrin LFA-1.. J Cell Biol. 1992; 116(1):219-26. (Clone-specific: Flow cytometry, Immunoprecipitation). 查看参考
  3. Dransfield I, Hogg N. Regulated expression of Mg2+ binding epitope on leukocyte integrin alpha subunits.. EMBO J. 1989; 8(12):3759-65. (Clone-specific: Flow cytometry, Immunoprecipitation). 查看参考
  4. Hogg N, Selvendran Y. An anti-human monocyte/macrophage monoclonal antibody, reacting most strongly with macrophages in lymphoid tissue.. Cell Immunol. 1985; 92(2):247-53. (Immunogen: Flow cytometry, Immunofluorescence, Immunohistochemistry, Immunoprecipitation, Radioimmunoassay). 查看参考
  5. Kamata T, Tieu KK, Tarui T, Puzon-McLaughlin W, Hogg N, Takada Y. The role of the CPNKEKEC sequence in the beta(2) subunit I domain in regulation of integrin alpha(L)beta(2) (LFA-1).. J Immunol. 2002; 168(5):2296-301. (Clone-specific: Flow cytometry). 查看参考
  6. Lefort CT, Rossaint J, Moser M, et al. Distinct roles for talin-1 and kindlin-3 in LFA-1 extension and affinity regulation.. Blood. 2012; 119(18):4275-82. (Clone-specific: Flow cytometry). 查看参考
  7. Wen L, Marki A, Wang Z, et al. A humanized β2 integrin knockin mouse reveals localized intra- and extravascular neutrophil integrin activation in vivo.. Cell Rep. 2022; 39(9):110876. (Clone-specific: Activation, Flow cytometry, Fluorescence activated cell sorting, Immunofluorescence, Stimulation). 查看参考
查看所有文件 (7) 查看更少内容
755487 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.