RB705 Mouse Anti-Human CD326 (EpCAM)
RB705 Mouse Anti-Human CD326 (EpCAM)
Flow cytometric analysis of CD326 (EpCAM) expression on Human colorectal adenocarcinoma cells.  Cells from the Human HT-29 (Colorectal Carcinoma, ATCC® HTB-38™) cell line were stained with BD Horizon™ RB705 Mouse IgG2b, κ Isotype Control (Cat. No. 570273; dashed line histogram) or BD Horizon™ RB705 Mouse Anti-Human CD326 (EpCAM) antibody (Cat. No. 570585/570673; solid line histogram). DAPI Solution (Cat. No. 564907) was added to cells right before analysis. The histogram showing CD326 (EpCAM) expression [or Ig Isotype control staining] was derived from gated events with the forward and side-light scatter characteristics of viable (DAPI-negative) cells. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software.
Flow cytometric analysis of CD326 (EpCAM) expression on Human colorectal adenocarcinoma cells.  Cells from the Human HT-29 (Colorectal Carcinoma, ATCC® HTB-38™) cell line were stained with BD Horizon™ RB705 Mouse IgG2b, κ Isotype Control (Cat. No. 570273; dashed line histogram) or BD Horizon™ RB705 Mouse Anti-Human CD326 (EpCAM) antibody (Cat. No. 570585/570673; solid line histogram). DAPI Solution (Cat. No. 564907) was added to cells right before analysis. The histogram showing CD326 (EpCAM) expression [or Ig Isotype control staining] was derived from gated events with the forward and side-light scatter characteristics of viable (DAPI-negative) cells. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software.
商品详情
Down Arrow Up Arrow


BD Horizon™
EGP-2; EGP314; EGP40; EPCAM; ESA; GA733-2; KSA; M4S1; MIC18; MK-1; TACSTD1; TROP1; adenocarcinoma-associated antigen
Human (QC Testing)
Mouse BALB/c IgG2b, κ
Human breast carcinoma Cell Line
Flow cytometry (Routinely Tested)
5 µl/test
VIII 80168
4072
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

商品通知

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. An isotype control should be used at the same concentration as the antibody of interest.
  7. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  8. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  9. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  10. Tandem fluorochromes contain both an energy donor and an energy acceptor. Although every effort is made to minimize the lot-to-lot variation in the efficiency of the fluorochrome energy transfer, differences in the residual emission from the donor may be observed. Additionally, multi-laser cytometers may directly excite both the donor and acceptor fluorochromes. Therefore, we recommend for every tandem conjugate, a matched individual single-stain control be acquired for generating a compensation or spectral unmixing matrix.
  11. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
  12. For U.S. patents that may apply, see bd.com/patents.
570585 Rev. 1
抗体详情
Down Arrow Up Arrow
9C4

The 9C4 monoclonal antibody specifically binds to human epithelial cell adhesion molecule (EpCAM), also known as adenocarcinoma associated antigen and CD326. EpCAM is an approximately 40-kDa type 1 transmembrane glycoprotein and adhesion molecule that mediates intercellular interactions via homotypic adhesion. The epithelial cells present in non-squamous epithelia and tumors derived from such cells show EpCAM expression. Tumors arising from non-epithelial cells, such as lymphoma, mesothelioma, neuroblastoma, and melanoma, do not express EpCAM. The normal epithelial cells reactive with anti-EpCAM antibodies are those present in the (lower) respiratory tract; the (lower) gastrointestinal tract; tubules in the kidney; the surface epithelium of the ovary; the exocrine and endocrine pancreas; secondary germ cells of telogenic hair follicles; and secretory tubules of sweat glands in the skin, whereas the epidermis is negative. In addition, all epithelial cells in the thyroid and epithelial cells in the thymus show EpCAM expression, while the outer cortex and Hassall's corpuscles have low expression. EpCAM is expressed on a variety of stem and progenitor cells, and its down-regulation is associated with decreased proliferation and differentiation toward endoderm and mesoderm lineages.

570585 Rev. 1
格式详情
Down Arrow Up Arrow
RB705
The BD Horizon RealBlue™ 705 (RB705) Dye is part of the BD® family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 707-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RB705 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), RB705 can be used as an alternative to PerCP-Cy5.5 or BB700 and we recommend using an optical filter centered near 710-nm (e.g., a 695/40 or 710/50-nm bandpass filter). For spectral instruments equipped with a Blue laser (488-nm), it can be used in conjunction with PerCP-Cy5.5. RB705 is on average brighter than PerCP-Cy5.5 and BB700, and has minimal spillover into Yellow-Green detectors.
altImg
RB705
Blue 488 nm
498 nm
707 nm
570585 Rev.1
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "570585" on CiteAb

研发参考 (5)

  1. Bühring HJ, Müller T, Herbst R, et al. The adhesion molecule E-cadherin and a surface antigen recognized by the antibody 9C4 are selectively expressed on erythroid cells of defined maturational stages.. Leukemia. 1996; 10(1):106-16. (Clone-specific: Flow cytometry). 查看参考
  2. Lammers R, Giesert C, Grünebach F, Marxer A, Vogel W, Bühring HJ. Monoclonal antibody 9C4 recognizes epithelial cellular adhesion molecule, a cell surface antigen expressed in early steps of erythropoiesis.. Exp Hematol. 2002; 30(6):537-45. (Clone-specific: Flow cytometry). 查看参考
  3. Ng VY, Ang SN, Chan JX, Choo AB. Characterization of epithelial cell adhesion molecule as a surface marker on undifferentiated human embryonic stem cells.. Stem Cells. 2010; 28(1):29-35. (Biology). 查看参考
  4. Patriarca C, Macchi RM, Marschner AK, Mellstedt H. Epithelial cell adhesion molecule expression (CD326) in cancer: a short review. Cancer Treat Rev. 2012; 38(1):68-75. (Biology). 查看参考
  5. Trzpis M, McLaughlin PM, de Leij LM, Harmsen MC. Epithelial cell adhesion molecule: more than a carcinoma marker and adhesion molecule. Am J Pathol. 2007; 171(2):386-395. (Biology). 查看参考
查看所有文件 (5) 查看更少内容
570585 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.