Skip to main content Skip to navigation
R718 Rat Anti-Mouse Ly-49A
R718 Rat Anti-Mouse Ly-49A
Multicolor flow cytometric analysis of Ly-49A expression on Mouse splenic leukocytes.  C57BL/6 Mouse splenocytes were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) [Cat. No. 553141/553142]. The cells were then stained with BD Horizon™ BV421 Rat Anti-Mouse CD49b antibody (Cat. No. 563063) and with either BD Horizon™ R718 Rat IgG2b, κ Isotype Control (Cat. No. 566943; Left Plot) or BD Horizon™ R718 Rat Anti-Mouse Ly-49A antibody (Cat. No. 570084/570165; Right Plot) at 1 μg/test. BD Via-Probe™ Cell Viability 7-AAD Solution (Cat. No. 555815/555816) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of Ly-49A (or Ig Isotype control staining) versus CD49b was derived from gated events with the forward and side light-scatter characteristics of viable (7-AAD-negative) splenic leukocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software. Data shown on this Technical Data Sheet are not lot specific.
Multicolor flow cytometric analysis of Ly-49A expression on Mouse splenic leukocytes.  C57BL/6 Mouse splenocytes were preincubated with Purified Rat Anti-Mouse CD16/CD32 antibody (Mouse BD Fc Block™) [Cat. No. 553141/553142]. The cells were then stained with BD Horizon™ BV421 Rat Anti-Mouse CD49b antibody (Cat. No. 563063) and with either BD Horizon™ R718 Rat IgG2b, κ Isotype Control (Cat. No. 566943; Left Plot) or BD Horizon™ R718 Rat Anti-Mouse Ly-49A antibody (Cat. No. 570084/570165; Right Plot) at 1 μg/test. BD Via-Probe™ Cell Viability 7-AAD Solution (Cat. No. 555815/555816) was added to cells right before analysis. The bivariate pseudocolor density plot showing the correlated expression of Ly-49A (or Ig Isotype control staining) versus CD49b was derived from gated events with the forward and side light-scatter characteristics of viable (7-AAD-negative) splenic leukocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software. Data shown on this Technical Data Sheet are not lot specific.
商品详情
Down Arrow Up Arrow


BD Horizon™
Klra1; lymphocyte antigen 49a; Ly-49a; Ly49a; YE1/48; A1
Mouse (QC Testing)
Rat F344, also known as Fischer, CDF IgG2b
ECA17.9.8 T Cell Line
Flow cytometry (Routinely Tested)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

商品通知

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. This product is provided under an Agreement between BIOTIUM and BD Biosciences. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  8. Alexa Fluor™ is a trademark of Life Technologies Corporation.
  9. For U.S. patents that may apply, see bd.com/patents.
570084 Rev. 1
抗体详情
Down Arrow Up Arrow
YE1/48.10.6

The YE1/48.10.6 monoclonal antibody specifically recognizes Lymphocyte antigen 49a (Ly-49A). Ly-49A is a single-pass type-II transmembrane that is encoded by Klra1 (Killer cell lectin-like receptor, subfamily A member 1) which belongs to the C-type lectin superfamily. Ly-49A is comprised of an extracellular carbohydrate-recognition domain (CRD) that can bind strongly to H-2D MHC class I alloantigens expressed on target cells including H-2D[d], H-2D[k], and H-2D[p]. The extracellular domain is followed by a transmembrane region and a cytoplasmic domain with an immunoreceptor tyrosine-based inhibitory motif (ITIM). Ly-49A is expressed as a  disulfide-linked homodimer on a subset of NK and NK-T cells. MHC Class I ligand-bound Ly-49A can negatively regulate NK-cell cytolytic activity via tyrosine phosphorylation of its ITIM.

570084 Rev. 1
格式详情
Down Arrow Up Arrow
R718
The BD Horizon™ Red 718 (R718) Dye is part of the BD red family of dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 695-nm and an emission maximum (Em Max) at 718-nm. Driven by BD innovation, R718 is designed to be excited by the red laser (627–640-nm) and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). R718 is a brighter alternative to Alexa Fluor™ 700. R718 is also a bright small molecule alternative to APC-R700 with lower spread into the APC detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
R718
Red 627-640 nm
695 nm
718 nm
570084 Rev.1
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "570084" on CiteAb

研发参考 (6)

  1. Chan PY, Takei F. Expression of a T cell receptor-like molecule on normal and malignant murine T cells detected by rat monoclonal antibodies to nonclonotypic determinants.. J Immunol. 1986; 136(4):1346-53. (Immunogen: Blocking, Flow cytometry, Immunoprecipitation, Western blot). 查看参考
  2. Mason LH, Gosselin P, Anderson SK, Fogler WE, Ortaldo JR, McVicar DW. Differential tyrosine phosphorylation of inhibitory versus activating Ly-49 receptor proteins and their recruitment of SHP-1 phosphatase. J Immunol. 1997; 159(9):4187-4196. (Biology: Blocking). 查看参考
  3. Nagasawa R, Gross J, Kanagawa O, et al. Identification of a novel T cell surface disulfide-bonded dimer distinct from the alpha/beta antigen receptor. J Immunol. 1987; 138(3):815-824. (Biology). 查看参考
  4. Nakamura MC, Seaman WE. Ligand interactions by activating and inhibitory Ly-49 receptors.. Immunol Rev. 2001; 181:138-48. (Biology). 查看参考
  5. Takei F. Two surface antigens expressed on proliferating mouse T lymphocytes defined by rat monoclonal antibodies.. J Immunol. 1983; 130(6):2794-7. (Immunogen: Flow cytometry, Radioimmunoassay, Western blot). 查看参考
  6. Zimmer J, Ioannidis V, Held W. H-2D ligand expression by Ly49A+ natural killer (NK) cells precludes ligand uptake from environmental cells: implications for NK cell function.. J Exp Med. 2001; 194(10):1531-9. (Clone-specific: Flow cytometry). 查看参考
查看所有文件 (6) 查看更少内容
570084 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.