BD Pharmingen™ PE Mouse Anti-Human CD79a
克隆 HM57 (RUO)
Flow cytometric analysis of CD79a expression in human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655) and permeabilized with BD Perm/Wash™ Buffer (Cat. No. 554723). The cells were subsequently stained with either PE Mouse Anti-Human CD79a antibody (Cat. No. 563777; solid line histogram) or PE Mouse IgG1, κ Isotype Control (Cat. No. 554680; dashed line histogram). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometric analysis was performed using a BD™ Canto II Flow Cytometer System.
Flow cytometric analysis of CD79a expression in human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655) and permeabilized with BD Perm/Wash™ Buffer (Cat. No. 554723). The cells were subsequently stained with either PE Mouse Anti-Human CD79a antibody (Cat. No. 563777; solid line histogram) or PE Mouse IgG1, κ Isotype Control (Cat. No. 554680; dashed line histogram). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometric analysis was performed using a BD™ Canto II Flow Cytometer System.
Flow cytometric analysis of CD79a expression in human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655) and permeabilized with BD Perm/Wash™ Buffer (Cat. No. 554723). The cells were subsequently stained with either PE Mouse Anti-Human CD79a antibody (Cat. No. 563777; solid line histogram) or PE Mouse IgG1, κ Isotype Control (Cat. No. 554680; dashed line histogram). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometric analysis was performed using a BD™ Canto II Flow Cytometer System.
监管状态图例
未经BD明确书面授权,严禁使用未经许可的任何商品。
准备和存储
商品通知
- This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
配套商品
The HM57 monoclonal antibody specifically binds to the cytoplasmic domain of CD79a. CD79a is a 47-kDa type 1 transmembrane glycoprotein present on B lymphocytes. CD79a is also referred to as mb-1, IGA and Ig-alpha (Ig-α). It is expressed on B cells at various stages of differentiation, from the pre-B cell stage, probably before expression of cytoplasmic μ chain, to the plasma cell stage, in which it is detected only in the cytoplasm. CD79a associates with CD79b to form part of the B-cell receptor complex. It has been suggested that CD79a may play a role in mediating the transport of IgM to the cell surface. This antibody reportedly may crossreact with monkey, mouse, rat, bovine, canine, chicken, equine, guinea pig, porcine, and rabbit CD79a.
研发参考 (6)
-
Engel P, Wagner N, Tedder TF. CD79 Workshop report. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:667-670.
-
Faldyna M, Sinkora J, Knotigova P, Rehakova Z, Moravkova A, Toman M. Flow cytometric analysis of bone marrow leukocytes in neonatal dogs. Vet Immunol Immunopathol. 2003; 95(3-4):165-176. (Clone-specific: Flow cytometry). 查看参考
-
Jones M, Cordell JL, Beyers AD, Tse AG, Mason DY. Detection of T and B cells in many animal species using cross-reactive anti-peptide antibodies. J Immunol. 1993; 150(12):5429-5435. (Clone-specific: Immunohistochemistry, Western blot). 查看参考
-
Mason DY, Cordell JL, Tse AG, et al. The IgM-associated protein mb-1 as a marker of normal and neoplastic B cells. J Immunol. 1991; 147(11):2474-2482. (Immunogen: Flow cytometry, Immunoaffinity chromatography, Immunofluorescence, Immunohistochemistry, Immunoprecipitation). 查看参考
-
Sakaguchi N, Kashiwamura S, Kimoto M, Thalmann P, Melchers F. B lymphocyte lineage-restricted expression of mb-1, a gene with CD3-like structural properties. EMBO J. 1988; 7(11):3457-3464. (Biology). 查看参考
-
Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.