Skip to main content Skip to navigation
BV786 Mouse Anti-Human TCR Cβ2
BV786 Mouse Anti-Human TCR Cβ2
Multiparameter flow cytometric analysis of TCR Cβ2 expression on Human peripheral blood lymphocytes.  Human whole blood was stained with BD OptiBuild™ RB545 Mouse Anti-Human TCR Cβ1 antibody (Cat. No. 756564) and with either BD Horizon™ BV786 Mouse IgG1, κ Isotype Control (Cat. No. 563330; Left Plot) or BD Horizon™ BV786 Mouse Anti-Human TCR Cβ2 antibody (Cat. No. 571834/571885; Right Plot) at 1 µg/test. Erythrocytes were lysed with BD FACS Lysing™ Solution (Cat. No. 349202). The bivariate pseudocolor density plot showing the correlated expression of TCR Cβ2 (or Ig Isotype control staining) versus side light-scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD FACSymphony™ A5 SE Cell Analyzer System and FlowJo™ Software. Data shown on this Technical Data Sheet are not lot specific.
Multiparameter flow cytometric analysis of TCR Cβ2 expression on Human peripheral blood lymphocytes.  Human whole blood was stained with BD OptiBuild™ RB545 Mouse Anti-Human TCR Cβ1 antibody (Cat. No. 756564) and with either BD Horizon™ BV786 Mouse IgG1, κ Isotype Control (Cat. No. 563330; Left Plot) or BD Horizon™ BV786 Mouse Anti-Human TCR Cβ2 antibody (Cat. No. 571834/571885; Right Plot) at 1 µg/test. Erythrocytes were lysed with BD FACS Lysing™ Solution (Cat. No. 349202). The bivariate pseudocolor density plot showing the correlated expression of TCR Cβ2 (or Ig Isotype control staining) versus side light-scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometry and data analysis were performed using a BD FACSymphony™ A5 SE Cell Analyzer System and FlowJo™ Software. Data shown on this Technical Data Sheet are not lot specific.
商品详情
Down Arrow Up Arrow


BD Horizon™
T cell receptor beta constant 2; TCR Cβ2; TCRBC2; TRBC2
Human (QC Testing)
Mouse IgG1, κ
Flow cytometry (Routinely Tested)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation).  When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime BD Horizon Brilliant dyes are used in a multicolor flow cytometry panel.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

商品通知

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  3. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  7. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  8. For U.S. patents that may apply, see bd.com/patents.
571885 Rev. 1
抗体详情
Down Arrow Up Arrow
SAM.2.rMAb

The SAM.2.rMAb is a recombinant monoclonal antibody that recognizes TCR Cβ2 expressed by a large proportion of CD4+ and CD8+ T cells. Thymocytes and mature peripheral T cells predominantly express a heterodimeric T cell receptor (TCR αβ) for antigen which is comprised of disulfide-liked transmembrane α and β chain subunits. The constant region of the TCR α subunit is encoded by TRAC, whereas the TCR β subunit is encoded by either of two highly homologous constant region genes, TCRB1 for TCR Cβ1 or TCRB2 for TCR Cβ2. The JOVI.1 antibody alternatively recognizes TCR Cβ1 expressed by the other TCR αβ+ T cells. These antibodies are effectively used together in multicolor staining and flow cytometric analyses to identify and characterize the natures of either TCR Cβ1+ or TCR Cβ2+ T cells in heterogeneous cell populations.

Note - Some human CD3- and TCR-specific antibodies might not be compatible to co-stain human T cells with SAM2.rMab. To confirm compatibility and immunofluorescent staining protocols, please visit: https://www.bdbiosciences.com/content/dam/bdb/marketing-documents/discover-learn/thought-leadership/events/POSTER-AAI%20202024-S-Riguad.pdf

571885 Rev. 1
格式详情
Down Arrow Up Arrow
BV786
The BD Horizon Brilliant Violet™ 786 (BV786) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an Ex Max of 407-nm and an acceptor dye with an Em Max at 786-nm.  BV786, driven by BD innovation, is designed to be excited by the violet laser and detected using a filter, centered near 785 nm (e.g. 780/60 nm bandpass filter).  Please ensure that your instrument’s configurations (lasers and filters) are appropriate for this dye.
altImg
BV786
Violet 405 nm
407 nm
786 nm
571885 Rev.1
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "571885" on CiteAb

研发参考 (7)

  1. Berg H, Otteson GE, Corley H, et al. Flow cytometric evaluation of TRBC1 expression in tissue specimens and body fluids is a novel and specific method for assessment of T-cell clonality and diagnosis of T-cell neoplasms.. Cytometry B Clin Cytom. 2021; 100(3):361-369. (Biology). 查看参考
  2. Ferrari M, Baldan V, Ghongane P, et al. Targeting TRBC1 and 2 for the treatment of T cell lymphomas. Abstract. Cancer Res. 2020; 80:2183. (Biology).
  3. Horna P, Shi M, Olteanu H, Johansson U. Emerging Role of T-cell Receptor Constant β Chain-1 (TRBC1) Expression in the Flow Cytometric Diagnosis of T-cell Malignancies.. Int J Mol Sci. 2021; 22(4):1817. (Biology). 查看参考
  4. Maciocia PM, Wawrzyniecka PA, Philip B, et al. Targeting the T cell receptor β-chain constant region for immunotherapy of T cell malignancies.. Nat Med. 2017; 23(12):1416-1423. (Biology). 查看参考
  5. Morath A, Schamel WW. αβ and γδ T cell receptors: Similar but different.. J Leukoc Biol. 2020; 107(6):1045-1055. (Biology). 查看参考
  6. Muñoz-García N, Lima M, Villamor N, et al. Anti-TRBC1 Antibody-Based Flow Cytometric Detection of T-Cell Clonality: Standardization of Sample Preparation and Diagnostic Implementation.. Cancers (Basel). 2021; 13(17):4379. (Biology). 查看参考
  7. Tesio M. Subtle Differences to Make the Difference.. Hemasphere. 2018; 2(2):e38. (Biology). 查看参考
查看所有文件 (7) 查看更少内容
571885 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.