Skip to main content Skip to navigation
Anti-Human CD8 FITC/CD56 PE/CD3 PerCP-Cy™5.5

BD Oncomark™ Anti-Human CD8 FITC/CD56 PE/CD3 PerCP-Cy™5.5

商品详情
Down Arrow Up Arrow


BD Oncomark™
Human
Flow cytometry
RUO (GMP)
AB_647414
Buffered saline with BSA and 0.1% sodium azide.


描述

CD8, clone SK1, is derived from hybridization of mouse NS-1 myeloma cells with spleen cells from BALB/c mice immunized with human peripheral blood T lymphocytes.

CD56, clone NCAM16.2, is derived from the hybridization of mouse P3X-63-Ag8.653 cells with lymph nodes from BALB/c mice immunized with immunoaffinity-enriched adult human brain NCAM.

CD3, clone SK7, is derived from hybridization of mouse NS-1 myeloma cells with spleen cells from BALB/c mice immunized with human thymocytes.

The CD8 antigen is expressed on the 32-kilodalton (kd) α subunit of a disulfide-linked bimolecular complex.The majority of peripheral blood CD8+ T lymphocytes expresses an α/β heterodimer (Mr 32, 30 kd), while CD8+CD16+ NK lymphocytes and CD8+ T-cell receptor (TCR)- γ/δ+ T lymphocytes express an α/α homodimer (Mr 30 kd). CD8+ TCR- α/β + T lymphocytes can express either an α/α homodimer or an α/β heterodimer.

CD56 (NCAM16.2) recognizes an extracellular immunoglobulin-like domain common to three molecular weight forms (Mr 120, 140, and 180 kd) of the neural cell adhesion molecule (NCAM).

CD3 reacts with the epsilon chain of the CD3 antigen/TCR complex. This complex is composed of at least six proteins that range in molecular weight from 20 to 30 kd. The antigen recognized by CD3 antibodies is noncovalently associated with either α/β or γ/δ TCR (70 to 90 kd).

准备和存储

Store vials at 2° to 8°C. Do not freeze reagents; protect them from prolonged exposure to light. Each reagent is stable for the period shown on the bottle label when stored as directed.

341142 Rev. 1
组件
Down Arrow Up Arrow
描述 克隆 同型对照 EntrezGene ID
N/A N/A IgG1, κ N/A
341142 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures. 

 

Although not required, these products are manufactured in accordance with Good Manufacturing Practices.