Skip to main content Skip to navigation
BUV737 Rat Anti-Mouse IFN-γ
Alert icon
This product is the replacement for [564693].
BUV737 Rat Anti-Mouse IFN-γ
Two color flow cytometric analysis of IFN-γ expression in stimulated mouse splenocytes. Mouse splenic leucocytes were stimulated for 5 hours with Phorbol 12-Myristate 13-Acetate (PMA; Sigma P-8139; 50 ng/ml) and Ionomycin (Sigma I-0634; 1 μg/ml) in the presence of BD GolgiStop™ Protein Transport Inhibitor (containing Monensin) (Cat. No. 554724). The cells were preincubated with Purified Rat Anti-Mouse CD16/32 antibody (Mouse Fc Block™) (Cat. No. 553141/553142) and fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655). The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with PE Rat Anti-Mouse CD8a antibody (Cat. No. 553033/561095/553032) and either BD Horizon™ BUV737 Rat IgG1, κ Isotype Control (Cat. No. 612770; Left Plot) or BD Horizon BUV737 Rat Anti-Mouse IFN-γ antibody (Cat. No. 612769; Right Plot) at 0.25 µg/test by using the BD Biosciences Intracellular Cytokine Staining Protocol.        Pseudocolor density dot plots showing the correlated expression of IFN-γ (or Ig Isotype control staining) versus CD8a were derived from gated events with the forward and side light-scatter characteristic of intact stimulated leucocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Two color flow cytometric analysis of IFN-γ expression in stimulated mouse splenocytes. Mouse splenic leucocytes were stimulated for 5 hours with Phorbol 12-Myristate 13-Acetate (PMA; Sigma P-8139; 50 ng/ml) and Ionomycin (Sigma I-0634; 1 μg/ml) in the presence of BD GolgiStop™ Protein Transport Inhibitor (containing Monensin) (Cat. No. 554724). The cells were preincubated with Purified Rat Anti-Mouse CD16/32 antibody (Mouse Fc Block™) (Cat. No. 553141/553142) and fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655). The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with PE Rat Anti-Mouse CD8a antibody (Cat. No. 553033/561095/553032) and either BD Horizon™ BUV737 Rat IgG1, κ Isotype Control (Cat. No. 612770; Left Plot) or BD Horizon BUV737 Rat Anti-Mouse IFN-γ antibody (Cat. No. 612769; Right Plot) at 0.25 µg/test by using the BD Biosciences Intracellular Cytokine Staining Protocol.        Pseudocolor density dot plots showing the correlated expression of IFN-γ (or Ig Isotype control staining) versus CD8a were derived from gated events with the forward and side light-scatter characteristic of intact stimulated leucocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Product Details
Down Arrow Up Arrow


BD Horizon™
Ifg; Ifng; IFN-γ; IFN-g; IFN-gamma; Interferon gamma; Type II Interferon
Mouse (QC Testing)
Rat IgG1, κ
Mouse IFN-γ Recombinant Protein
Intracellular staining (flow cytometry) (Routinely Tested)
0.2 mg/ml
15978
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BUV737 under optimum conditions, and unconjugated antibody and free BD Horizon BUV737 were removed.

Recommended Assay Procedures

  BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome-conjugated antibodies are bound to BD CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD CompBeads. This will ensure that BD CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Note:  When using high concentrations of antibody, background binding of this dye to erythroid cell subsets (mature erythrocytes and precursors) has been observed.  For researchers studying these cell populations, or in cases where light scatter gating does not adequately exclude these cells from the analysis, this background may be an important factor to consider when selecting reagents for panel(s).

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. BD Horizon Brilliant Ultraviolet 737 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,575,303; 8,354,239.
  6. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
612769 Rev. 2
Antibody Details
Down Arrow Up Arrow
XMG1.2

The XMG1.2 monoclonal antibody specifically binds to mouse interferon-γ (IFN-γ) protein. IFN-γ is a pleiotropic cytokine, of approximately 15-17 kDa, involved in the regulation of inflammatory and immune responses. It plays an important role in activation, growth, and differentiation of T and B lymphocytes, macrophages, NK cells and other non-hematopoietic cell types. IFN-γ production is associated with the Th1 cell differentiation. The purified form of this antibody has been reported to be a neutralizing antibody.

 

The antibody was conjugated to BD Horizon BUV737 which is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This dye is a tandem fluorochrome with an Ex Max near 350 nm and an Em Max near 737 nm. BD Horizon Brilliant BUV737 can be excited by the ultraviolet laser (355 nm) and detected with a 740/35 nm filter. Due to the excitation of the acceptor dye by the red laser line, there may be significant spillover into red laser detectors with filters in the 700-720 nm range.

612769 Rev. 2
Format Details
Down Arrow Up Arrow
BUV737
The BD Horizon Brilliant™ Ultraviolet 737 (BUV737) Dye is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This tandem fluorochrome is comprised of a BUV395 donor with an excitation maximum (Ex Max) of 350-nm and an acceptor dye with an emission maximum (Em Max) at 735-nm. BUV737, driven by BD innovation, is designed to be excited by the ultraviolet laser (355-nm) and detected using an optical filter centered near 740-nm (e.g., 740/35 bandpass filter). The acceptor dye can be excited by the Red (628–640nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BUV737
Ultraviolet 355 nm
350 nm
735 nm
612769 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (7)

  1. Abrams JS, Roncarolo MG, Yssel H, Andersson U, Gleich GJ, Silver JE. Strategies of anti-cytokine monoclonal antibody development: immunoassay of IL-10 and IL-5 in clinical samples. Immunol Rev. 1992; 127:5-24. (Clone-specific: ELISA, Neutralization). View Reference
  2. Cherwinski HM, Schumacher JH, Brown KD, Mosmann TR. Two types of mouse helper T cell clone. III. Further differences in lymphokine synthesis between Th1 and Th2 clones revealed by RNA hybridization, functionally monospecific bioassays, and monoclonal antibodies. J Exp Med. 1987; 166(5):1229-1244. (Clone-specific: ELISA). View Reference
  3. Klinman D and Nutman T. ELISPOT assay to detect cytokine-secreting murine and human cells. In: Coligan J, Kruisbeek A, Margulies D, Shevach E, Strober W, ed. Current Protocols in Immunology. 1994:6-19.
  4. Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Methodology). View Reference
  5. Sander B, Hoiden I, Andersson U, Moller E, Abrams JS. Similar frequencies and kinetics of cytokine producing cells in murine peripheral blood and spleen. Cytokine detection by immunoassay and intracellular immunostaining. J Immunol Methods. 1993; 166(2):201-214. (Clone-specific). View Reference
  6. Suzuki Y, Yang Q, Conley FK, Abrams JS, Remington JS. Antibody against interleukin-6 reduces inflammation and numbers of cysts in brains of mice with toxoplasmic encephalitis. Infect Immun. 1994; 62(7):2773-2778. (Clone-specific: In vivo exacerbation, Neutralization). View Reference
  7. Yang X, HayGlass KT. A simple, sensitive, dual mAb based ELISA for murine gamma interferon determination: comparison with two common bioassays. J Immunoassay. 1993; 14(3):129-148. (Clone-specific: ELISA). View Reference
View All (7) View Less
612769 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.