V450 Mouse IgG1, κ Isotype Control
Clone X40 (RUO)
- Brand BD Horizon™
- Concentration 0.2 mg/ml
- Isotype Mouse BALB/c IgG1, κ
- Reactivity Mouse, Human, Rat (QC Testing)
- Application
Isotype control, Flow cytometry (Routinely Tested)
- Immunogen Keyhole limpet hemocyanin (KLH)
- Storage Buffer Aqueous buffered solution containing protein stabilizer and ≤0.09% sodium azide.
- Regulatory Status RUO
Regulatory Status Legend
Description
The X40 hybridoma was derived from the fusion of mouse Sp2/0-Ag 14 myeloma cells with spleen cells from BALB/c mice immunized with keyhole limpet hemocyanin (KLH). The hybridoma secretes monoclonal antibody that binds specifically to KLH, an antigen not expressed on human cells or human cell lines.
The antibody is conjugated to BD Horizon™ V450, which has been developed for use in multicolor flow cytometry experiments and is available exclusively from BD Biosciences. It is excited by the Violet laser Ex max of 406 nm and has an Em Max at 450 nm. Conjugates with BD Horizon™ V450 can be used in place of Pacific Blue™ conjugates.
Format
BD Horizon™ V450 is a coumarin dye excited by the violet laser that exhibits spectral properties similar to Pacific Blue™. Conjugates are typically as bright or brighter than comparable reagents conjugated to Pacific Blue™. Due to nearly identical excitation and emission properties but different spillover characteristics, BD Horizon BV421, Pacific Blue™, and BD Horizon V450 cannot be used simultaneously.
Suggested Companion Products
Purified Rat Anti-Mouse CD16/CD32 (Mouse BD Fc Block™) 2.4G2 RUO
0.1 mg
Cat No: 553141
Stain Buffer (FBS) RUO
500 mL
Cat No: 554656
Resources & Tools | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Download TDS | Regulatory Document Website |
Preparation and Storage
The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography.
The antibody was conjugated with BD Horizon™ V450 under optimum conditions, and unreacted BD Horizon™ V450 was removed.
Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- An isotype control should be used at the same concentration as the antibody of interest.
- BD Horizon V450 has a maximum absorption of 406 nm and maximum emission of 450 nm. Before staining with this reagent, please confirm that your flow cytometer is capable of exciting the fluorochrome and discriminating the resulting fluorescence.
- Pacific Blue™ is a trademark of Molecular Probes, Inc., Eugene, OR.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.