BV421 Mouse Anti-Human CD10
BV421 Mouse Anti-Human CD10
Flow cytometric analysis using BD OptiBuild™ BV421 Mouse Anti-Human CD10 antibody (Cat. No. 744765; solid line histogram) on live REH cells, with corresponding Isotype Control (dotted line histogram). Flow cytometry was performed using a BD LSRFortessa™ Flow Cytometer System.
Flow cytometric analysis using BD OptiBuild™ BV421 Mouse Anti-Human CD10 antibody (Cat. No. 744765; solid line histogram) on live REH cells, with corresponding Isotype Control (dotted line histogram). Flow cytometry was performed using a BD LSRFortessa™ Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD OptiBuild™
Atriopeptidase; CALLA; Enkephalinase; EPN;Neutral endopeptidase; Neprilysin
Human (Tested in Development)
Mouse IgG1, κ
NALM-6 Pre–B-cell Line
Flow cytometry (Qualified)
0.2 mg/ml
IV B-506; V B-CD10.4
4311
AB_2742465
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation).  When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime BD Horizon Brilliant dyes are used in a multicolor flow cytometry panel.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. Researchers should determine the optimal concentration of this reagent for their individual applications.
  8. BD Horizon Brilliant Violet 421 is covered by one or more of the following US patents: 8,158,444; 8,362,193; 8,575,303; 8,354,239.
  9. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  10. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  11. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  12. Pacific Blue™ is a trademark of Life Technologies Corporation.
744765 Rev. 3
Antibody Details
Down Arrow Up Arrow
MEM-78

The MEM-78 monoclonal antibody specifically recognizes CD10. CD10 is a 100 kDa type II transmembrane, glycosylated, zinc-containing metalloprotease. The CD10 antigen is also known as common acute lymphoblastic leukemia antigen (CALLA), neutral endopeptidase (NEP), gp100, and enkephalinase. The CD10 antigen is found on lymphocytes from samples with acute B-lymphoid leukemia. The CD10 antigen is also present on a wide variety of normal and neoplastic cell types including renal epithelia, fibroblasts, granulocytes, germinal center B lymphocytes, neutrophils, some T-cell leukemias, and some lymphoma, melanoma, and glioma cell lines. The CD10 antigen cleaves a number of biologically active peptides, including fMLP, and may modulate the chemotactic activity of fMLP towards neutrophils. Inhibition of the CD10 antigen promotes B-cell maturation, suggesting that it plays a role in B-cell development.

744765 Rev. 3
Format Details
Down Arrow Up Arrow
BV421
The BD Horizon Brilliant Violet™ 421 (BV421) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This polymer-technology based dye has an excitation maximum (Ex Max) of 407-nm and an emission maximum (Em Max) at 423-nm. Driven by BD innovation, BV421 is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 420-nm (e.g., a 431/28-nm or 450/50-nm bandpass filter). BV421 is an ideal alternative for V450 as it is approximately ten times brighter with less spillover into the BV510/V500 detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV421
Violet 405 nm
407 nm
423 nm
744765 Rev.3
Citations & References
Down Arrow Up Arrow

Development References (14)

  1. Caligaris-Cappio F, Riva M, Tesio L, Schena M, Gaidano G, Bergui L. Human normal CD5+ B lymphocytes can be induced to differentiate to CD5- B lymphocytes with germinal center cell features.. Blood. 1989; 73(5):1259-63. (Biology). View Reference
  2. Connelly JC, Chambless R, Holiday D, Chittenden K, Johnson AR. Up-regulation of neutral endopeptidase (CALLA) in human neutrophils by granulocyte-macrophage colony-stimulating factor.. J Leukoc Biol. 1993; 53(6):685-90. (Biology). View Reference
  3. Connelly JC, Skidgel RA, Schulz WW, Johnson AR, Erdös EG. Neutral endopeptidase 24.11 in human neutrophils: cleavage of chemotactic peptide.. Proc Natl Acad Sci USA. 1985; 82(24):8737-41. (Biology). View Reference
  4. Consolini R, Legitimo A, Rondelli R, et al. Clinical relevance of CD10 expression in childhood ALL. The Italian Association for Pediatric Hematology and Oncology (AIEOP).. Haematologica. 1998; 83(11):967-73. (Biology). View Reference
  5. Dörken B, Möller P, Pezzutto A, Schwartz-Albiez R, Moldenhauer G. B-cell antigens: CD10. In: :33-34. View Reference
  6. Erdös EG, Skidgel RA. Neutral endopeptidase 24.11 (enkephalinase) and related regulators of peptide hormones.. FASEB J. 1989; 3(2):145-51. (Biology). View Reference
  7. Erdös EG, Wagner B, Harbury CB, Painter RG, Skidgel RA, Fa XG. Down-regulation and inactivation of neutral endopeptidase 24.11 (enkephalinase) in human neutrophils.. J Biol Chem. 1989; 264(24):14519-23. (Biology). View Reference
  8. Hofman P, Selva E, Le Negrate G, et al. CD10 inhibitors increase f-Met-Leu-Phe-induced neutrophil transmigration.. J Leukoc Biol. 1998; 63(3):312-20. (Biology). View Reference
  9. Horejsi V, Angelisova P, Bazil V, et al. Monoclonal antibodies against human leucocyte antigens. II. Antibodies against CD45 (T200), CD3 (T3), CD43, CD10 (CALLA), transferrin receptor (T9), a novel broadly expressed 18-kDa antigen (MEM-43) and a novel antigen of restricted expression (MEM-74). Folia Biologica. 1988; 34(1):23-34. (Clone-specific).
  10. LeBien TW, McCormack RT. The common acute lymphoblastic leukemia antigen (CD10)--emancipation from a functional enigma.. Blood. 1989; 73(3):625-35. (Biology). View Reference
  11. Letarte M, Vera S, Tran R, et al. Common acute lymphocytic leukemia antigen is identical to neutral endopeptidase. J Exp Med. 1988; 168(4):1247-1253. (Biology). View Reference
  12. Salles G, Rodewald HR, Chin BS, Reinherz EL, Shipp MA. Inhibition of CD10/neutral endopeptidase 24.11 promotes B-cell reconstitution and maturation in vivo.. Proc Natl Acad Sci USA. 1993; 90(16):7618-22. (Biology). View Reference
  13. Zola H. CD10 Workshop Panel report. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:505-507.
  14. Zola H. CD10. In: Zola H. Leukocyte and stromal cell molecules : the CD markers. Hoboken, N.J.: Wiley-Liss; 2007:55.
View All (14) View Less
744765 Rev. 3

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.