Skip to main content Skip to navigation
PE Mouse Anti-Human CD29
PE Mouse Anti-Human CD29
Flow cytometric analysis of CD29 expression on human peripheral blood lymphocytes.  Whole blood was stained with PE Mouse Anti-Human CD29 antibody (Cat. No. 555443/557332/561795; solid line histogram) or with a PE  Mouse IgG1, κ Isotype Control (Cat. No. 555749; dashed line histogram). Erythrocytes were lysed with BD PharmLyse™ Lysing Buffer (Cat. No. 555899). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of viable lymphocytes. Flow cytometric analysis was carried out on a BD FACScan™ system.
Flow cytometric analysis of CD29 expression on human peripheral blood lymphocytes.  Whole blood was stained with PE Mouse Anti-Human CD29 antibody (Cat. No. 555443/557332/561795; solid line histogram) or with a PE  Mouse IgG1, κ Isotype Control (Cat. No. 555749; dashed line histogram). Erythrocytes were lysed with BD PharmLyse™ Lysing Buffer (Cat. No. 555899). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of viable lymphocytes. Flow cytometric analysis was carried out on a BD FACScan™ system.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
ITGB1; Integrin beta-1; Integrin β1; FNRB; GPIIA; ITB1; MDF2; MSK12; VLA-4β
Human (QC Testing), Rhesus, Cynomolgus, Baboon (Tested in Development)
Mouse BALB/c IgG1, κ
Purified Human α5β1 Fibronectin Receptor
Flow cytometry (Routinely Tested)
20 µl
VI A093
3688
AB_395836
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  5. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
561795 Rev. 2
Antibody Details
Down Arrow Up Arrow
MAR4

The MAR4 monoclonal antibody specifically binds to CD29. CD29 is a 130 kDa integrin β1 subunit that is expressed as a heterodimeric complex with one of six distinct α subunits, comprising the very late activation antigen (VLA) subfamily of adhesion receptors. The β1 subunit has a broad tissue distribution; it is expressed on lymphocytes, monocytes and weakly on granulocytes, but not on erythrocytes. These receptors are involved in a variety of cell-cell and cell-matrix interactions.

561795 Rev. 2
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
561795 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (4)

  1. Hemler ME. VLA proteins in the integrin family: structures, functions, and their role on leukocytes. Annu Rev Immunol. 1990; 8:365-400. (Biology). View Reference
  2. Hynes RO. Integrins: versatility, modulation, and signaling in cell adhesion. Cell. 1992; 69(1):11-25. (Biology). View Reference
  3. Pellegrini R, Bazzini P, Tosi E, et al. Production and characterization of two monoclonal antibodies directed against the integrin beta 1 chain. Tumori. 1992; 78(1):1-4. (Immunogen). View Reference
  4. Tanaka Y, Aso M, Takada Y. CD29 Workshop Panel report. In: Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997:357-360.
View All (4) View Less
561795 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.