Skip to main content Skip to navigation
Mouse Th1/Th2 Cytokine Cytometric Bead Array (CBA) Kit

BD™ Cytometric Bead Array (CBA) Mouse Th1/Th2 Cytokine Cytometric Bead Array (CBA) Kit

(RUO)
Product Details
Down Arrow Up Arrow


BD™ Cytometric Bead Array (CBA)
RUO
AB_2868929


Description

The BD™ CBA Mouse Th1/Th2 Cyokine Kit (Catalog No. 551287) can be used to measure Interleukin-2 (IL-2), Interleukin-4 (IL-4), Interleukin-5 (IL-5), Interferon-γ (IFN-γ), and Tumor Necrosis Factor (TNF) protein levels in a single sample. The kit performance has been optimized for analysis of physiologically relevant concentrations (pg/mL levels) of specific cytokine proteins in tissue culture supernatants and serum samples. The kit provides sufficient reagents for the quantitative analysis of 80 samples.

 

Vial LabelReagentQuantity
 A1 Mouse IL-2 Capture Beads 1 vial, 0.8 mL
 A2 Mouse IL-4 Capture Beads 1 vial, 0.8 mL
 A3 Mouse IL-5 Capture Beads 1 vial, 0.8 mL
 A4 Mouse IFN-γ Capture Beads 1 vial, 0.8 mL
 A5 Mouse TNF Capture Beads 1 vial, 0.8 mL
 B Mouse Th1/Th2 PE Detection Reagent 1 vial, 4 mL
 C Mouse Th1/Th2 Cytokine Standards 2 vials lyophilized
 D Cytometer Setup Beads 1 vial, 1.5 mL
 E PE Positive Control Detector 1 vial, 0.5 mL
 E2 FITC Positive Control Detector 1 vial, 0.5 mL
 F Wash Buffer 1 bottle, 130 mL
 G Assay Diluent 1 bottle, 30 mL

 

551287 Rev. 1
Components
Down Arrow Up Arrow
Description Quantity/Size Part Number EntrezGene ID
Mouse IL-2 Capture Beads 0.8 mL (1 ea) 51-9005801 N/A
Mouse IL-4 Capture Beads 0.8 mL (1 ea) 51-9005803 N/A
Mouse IL-5 Capture Beads 0.8 mL (1 ea) 51-9005805 N/A
Mouse IFN-γ Capture Beads 0.8 mL (1 ea) 51-9005807 N/A
Mouse TNF Capture Beads 0.8 mL (1 ea) 51-9005809 N/A
B) Mouse Th1/Th2 PE Detection Reagent N/A 51-2523KC N/A
Mouse Th1/Th2 Cytokine Standards N/A 51-2524KC N/A
D Cytometer Setup Beads 1 Each (1 ea) 51-9005731 N/A
E1 PE Positive Control Detector 1 Each (1 ea) 51-9005732 N/A
E2 FITC Positive Control Detector 1 Each (1 ea) 51-9005734 N/A
F Wash Buffer 1 Each (1 ea) 51-2431KC N/A
G Assay Diluent 1 Each (1 ea) 51-2432KC N/A
551287 Rev. 1
Citations & References
Down Arrow Up Arrow

Development References (13)

  1. Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology).
  2. Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology).
  3. Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology).
  4. Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology).
  5. Collins DP, Luebering BJ, Shaut DM. T-lymphocyte functionality assessed by analysis of cytokine receptor expression, intracellular cytokine expression, and femtomolar detection of cytokine secretion by quantitative flow cytometry. Cytometry. 1998; 33:249-255. (Biology).
  6. Cook, EB, JL Stahl, et al. Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs non-allergics. J Immunol Methods. 2001; 254:109-118. (Biology).
  7. Dotti, G, B Salvodo, et al. Adenovector-induced expression of human-CD40-ligand (hCD40L) by multiple myeloma cells: A model for immunotherapy. Exp Hematol. 2001; 29:952-961. (Biology).
  8. Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem. 1997; 43:1749-1756. (Biology).
  9. Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404.
  10. Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology). View Reference
  11. McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology). View Reference
  12. Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology).
  13. Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).
View All (13) View Less
551287 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.