BV480 Mouse Anti-Human CD79b
Clone 3A2-2E7 (also known as SN8) (RUO)
- Brand
BD OptiBuild™
BD OptiBuild custom reagents make BD Horizon Brilliant™ dyes readily available across a wide selection of cell surface antibodies. Learn more about what makes BD OptiBuild reagents unique Learn more at bdbiosciences.com/go/optibuild - Alternative Name Igβ; B29; IGB; AGM6; CD79B
- Concentration 0.2 mg/ml
- Isotype Mouse BALB/c IgG1, κ
- Reactivity Human (Tested in Development)
- Application
Flow cytometry (Qualified)
- Immunogen Cell membranes from human B-prol ymphocytic leukemia (B-PLL) cells
- Workshop No. V B037
- Entrez Gene ID 974
- Storage Buffer Aqueous buffered solution containing ≤0.09% sodium azide.
- Regulatory Status RUO
Regulatory Status Legend
Description
The 3A2-2E7 monoclonal antibody (also known as SN8) specifically recognizes CD79b. Immunoglobulin (Ig) antigen receptors are composed of a non-covalently-associated complex of Ig and two other proteins, Igα and Igβ, clustered as CD79a and CD79b, respectively. CD79b is a membrane glycoprotein of 229 residues, with a predicted relative molecular mass of 36-40 kDa. Its expression is restricted to B lineage cells. CD79b reportedly associates with surface IgM and is involved in signal transduction. The 3A2-2E7 antibody has similar reactivity characteristics as clone CB3-1. The 3A2-2E7 and CD3-1 antibodies specifically react with an epitope that is enhanced on certain B-cell leukemias such as prolymphocytic leukemia and lymphoma, but not on chronic lymphocytic leukemia.
The antibody was conjugated to BD Horizon™ BV480 which is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 436-nm and Em Max at 478-nm, BD Horizon BV480 can be excited by the violet laser and detected in the BD Horizon BV510 (525/40-nm) filter set. BV480 has less spillover into the BV605 detector and, in general, is brighter than BV510.
Format
BD Horizon™ BV480 is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 436-nm and Em Max at 478-nm, BD Horizon BV480 can be excited by the violet laser and detected in the BD Horizon™ BV510 (525/40-nm) filter set. BV480 has less spillover into the BD Horizon™ BV605 detector and, in general, is brighter than BD Horizon BV510. Due to similar excitation and emission properties, BV480, BV510 and V500 cannot be used simultaneously.
Suggested Companion Products
Human BD Fc Block™ RUO
50 mg
Cat No: 564219
Lysing Solution 10X Concentrate IVD
100
Cat No: 349202
BV480 Mouse IgG1, k Isotype Control RUO
50 µg
Cat No: 565652
Stain Buffer (FBS) RUO
500 mL
Cat No: 554656
Stain Buffer (BSA) RUO
500 mL
Cat No: 554657
Brilliant Stain Buffer RUO
100 Tests
Cat No: 563794
Lysing Buffer RUO
100 mL
Cat No: 555899
Resources & Tools | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Panel Designer | Spectrum Viewer | Regulatory Document Website | Download TDS |
Preparation and Storage
Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.
The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography.
The antibody was conjugated with BD Horizon BV480 under optimal conditions that minimize unconjugated dye and antibody.
Product Notices
- This antibody was developed for use in flow cytometry.
- The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
- Researchers should determine the optimal concentration of this reagent for their individual applications.
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
- BD Horizon Brilliant Violet 480 is covered by one or more of the following US patents: 8,575,303; 8,354,239.
For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).