Skip to main content Skip to navigation
Alexa Fluor® 700 Mouse Anti-Human IgG
Alert icon
Consider BD Horizon™ Red 718 Reagents, bright small molecule alternative to BD Pharmingen™ Alexa Fluor™ 700 with low background. More Info #
Alexa Fluor® 700 Mouse Anti-Human IgG
Flow cytometric analysis of IgG expression on human peripheral blood lymphocytes. Human peripheral blood mononuclear cells (PBMC) were washed and cultured in complete tissue culture medium overnight in order to minimize nonspecific immunofluorescent staining. The cells were harvested and stained with PE Mouse anti-Human CD19 (Cat. No. 555413) and either Alexa Fluor® 700 Mouse anti-Human IgG antibody (Cat. No. 561296; Right Panel) or with an Alexa Fluor® 700  Mouse IgG1, κ Isotype Control (Cat. No. 557882; Left Panel). Two-color flow cytometric dot plots showing the correlated expression of cell surface IgG (or Ig isotype control staining) versus CD19 were derived from gated events with the forward and side light-scatter characteristics of viable lymphocytes. Flow cytometry was performed using a BD™ LSR II Flow Cytometer System.
Flow cytometric analysis of IgG expression on human peripheral blood lymphocytes. Human peripheral blood mononuclear cells (PBMC) were washed and cultured in complete tissue culture medium overnight in order to minimize nonspecific immunofluorescent staining. The cells were harvested and stained with PE Mouse anti-Human CD19 (Cat. No. 555413) and either Alexa Fluor® 700 Mouse anti-Human IgG antibody (Cat. No. 561296; Right Panel) or with an Alexa Fluor® 700  Mouse IgG1, κ Isotype Control (Cat. No. 557882; Left Panel). Two-color flow cytometric dot plots showing the correlated expression of cell surface IgG (or Ig isotype control staining) versus CD19 were derived from gated events with the forward and side light-scatter characteristics of viable lymphocytes. Flow cytometry was performed using a BD™ LSR II Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Human (QC Testing)
Mouse IgG1, κ
Flow cytometry (Routinely Tested)
5 µl
AB_10612406
Aqueous buffered solution containing protein stabilizer and ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to Alexa Fluor® 700 under optimum conditions, and unreacted Alexa Fluor® 700 was removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Alexa Fluor® 700 has an adsorption maximum of ~700nm and a peak fluorescence emission of ~720nm. Before staining cells with this reagent, please confirm that your flow cytometer is capable of exciting the fluorochrome and discriminating the resulting fluorescence.
  4. Alexa Fluor® is a registered trademark of Molecular Probes, Inc., Eugene, OR.
  5. The Alexa Fluor®, Pacific Blue™, and Cascade Blue® dye antibody conjugates in this product are sold under license from Molecular Probes, Inc. for research use only, excluding use in combination with microarrays, or as analyte specific reagents. The Alexa Fluor® dyes (except for Alexa Fluor® 430), Pacific Blue™ dye, and Cascade Blue® dye are covered by pending and issued patents.
  6. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  7. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  8. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
561296 Rev. 1
Antibody Details
Down Arrow Up Arrow
G18-145

IgG is an important component of the humoral immune response, helping to control infection.  IgG is produced by plasma B-cells and may be found in extracellular fluids, such as blood, lymph, peritoneal, and cerebrospinal fluids.  IgG monomers consist of two light and two heavy chains containing two antigen binding sites.  There are four IgG subclasses found in human, mouse and rat species, which include IgG1, IgG2, IgG3 and IgG4.  The G18-145 monoclonal antibody specifically binds to the heavy chain of human immunoglobulin G subclasses: IgG1, IgG2, IgG3 and IgG4.  The G18-145 antibody has been reported not to react with the heavy chains of other human immunoglobulin isotypes.

561296 Rev. 1
Format Details
Down Arrow Up Arrow
Alexa Fluor™ 700
Alexa Fluor™ 700 dye is part of the BD red family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 697 nm and an emission maximum (Em Max) at 719-nm. Alexa Fluor™ 700 is designed to be excited by the Red (627–640-nm) laser and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
Alexa Fluor™ 700
Red 627-640 nm
697 nm
719 nm
561296 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (1)

  1. Zola H, Macardle PJ, Flego L, Webster J. The expression of sub-population markers on B cells: a re-evaluation using high-sensitivity fluorescence flow cytometry. Dis Markers. 1991; 9(2):103-118. (Biology). View Reference
561296 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.